Tato stránka byla automaticky přeložena a přesnost překladu není zaručena. Podívejte se prosím na anglická verze pro zdrojový text.

Placental Perfusion in the Entire Placenta and With Sonobiopsy by Ultrasound

16. února 2022 aktualizováno: Andrea Suranyi, Szeged University

Correlation Between the Placental Perfusion Measured in the Entire Placenta and With Sonobiopsy

In this study is tested the validity of placental vascular indices obtained from placenta ultrasonographic sphere biopsy and entire placenta investigation.

Přehled studie

Detailní popis

Although, to this date, there have been a number of human placental studies that concerned the evaluation of placental 3 dimensional power Doppler vascularization with the use of VOCAL technique, but there was no one in which placental vasculature has been compared between the sonobiopsy and whole placental volume.

Typ studie

Intervenční

Zápis (Aktuální)

150

Fáze

  • Nelze použít

Kontakty a umístění

Tato část poskytuje kontaktní údaje pro ty, kteří studii provádějí, a informace o tom, kde se tato studie provádí.

Studijní místa

      • Szeged, Maďarsko, 6720
        • Universitiy of Szeged

Kritéria účasti

Výzkumníci hledají lidi, kteří odpovídají určitému popisu, kterému se říká kritéria způsobilosti. Některé příklady těchto kritérií jsou celkový zdravotní stav osoby nebo předchozí léčba.

Kritéria způsobilosti

Věk způsobilý ke studiu

18 let až 45 let (Dospělý)

Přijímá zdravé dobrovolníky

Ne

Pohlaví způsobilá ke studiu

Ženský

Popis

Exclusion criteria:

  • multiple pregnancy,
  • abnormal (> 3mm) nuchal translucency from 11+0 to 13+6 weeks of gestation,
  • the fetal or neonatal structural or chromosomal anomaly,
  • inadequate localization of the placenta (placenta praevia),
  • self-reported drugs, alcohol, caffeine or nicotine abuse,
  • exposed to circulatory medication (oxerutins, calcium dobesilate)
  • or not signing the consent form.
  • If the mother suffer from er systemic disease (e.g. diabetes, autoimmune disease, vasculitis, haemophilia, thrombophilia, HIV infection, etc)

Inclusion clriteria:

  • single pregnancy
  • healthy pregnant women
  • no anatomical alteration of fetus
  • no genetical abnormality of fetus

Studijní plán

Tato část poskytuje podrobnosti o studijním plánu, včetně toho, jak je studie navržena a co studie měří.

Jak je studie koncipována?

Detaily designu

  • Primární účel: Diagnostický
  • Přidělení: Nerandomizované
  • Intervenční model: Paralelní přiřazení
  • Maskování: Žádné (otevřený štítek)

Zbraně a zásahy

Skupina účastníků / Arm
Intervence / Léčba
Experimentální: Normal placenta-entitle
The 3-DPD indices was measured in the entire placenta volume.
Images that contributed to the determination of placental volume and 3-DPD indices were obtained at the time of visit. All 3-D scans ultrasound measurements were performed by a Voluson 730 Expert ultrasound machine equipped with a multifrequency probe (2-5 MHz) to acquire images. Each sample was examined using 3-D rendering mode, in which the colour and gray value information was processed and combined to supply 3-D image. For laterally located placentas, the investigator positioned the transducer on a slight lateral inclination to obtain proper images. Power Doppler window was placed over the placenta to map the vascular tree from basal to chorionic plates. The 3-D static volume box was placed over the entire placenta volume. The sweep angle was set at maximum 70°. Each image was recovered from the disk in succession for processing. During gestation, the investigator recorded one sample from each patient.
The two-dimensional (2-D) transabdominal conventional study provided data about fetal position, biometry, body movements and fetal heart rate as well as placental localization. The factorial default setting 'Obstetrics' was applied in 2-D mode.
Experimentální: Normal placenta-sonobyopsy
The 3-DPD indices was measured at cord insertion in placenta by sonobiopsy
Images that contributed to the determination of placental volume and 3-DPD indices were obtained at the time of visit. All 3-D scans ultrasound measurements were performed by a Voluson 730 Expert ultrasound machine equipped with a multifrequency probe (2-5 MHz) to acquire images. Each sample was examined using 3-D rendering mode, in which the colour and gray value information was processed and combined to supply 3-D image. For laterally located placentas, the investigator positioned the transducer on a slight lateral inclination to obtain proper images. Power Doppler window was placed over the placenta to map the vascular tree from basal to chorionic plates. The 3-D static volume box was placed over the entire placenta volume. The sweep angle was set at maximum 70°. Each image was recovered from the disk in succession for processing. During gestation, the investigator recorded one sample from each patient.
The two-dimensional (2-D) transabdominal conventional study provided data about fetal position, biometry, body movements and fetal heart rate as well as placental localization. The factorial default setting 'Obstetrics' was applied in 2-D mode.

Co je měření studie?

Primární výstupní opatření

Měření výsledku
Popis opatření
Časové okno
Maternal characteristics (BMI)
Časové okno: through study completion, 2 years
The pre-pregnancy body mass index (BMI) registered at the initial visit during prenatal care was calculated as the body weight (kg) per height (m2).
through study completion, 2 years
Neonatal outcome 1; based on gestational age
Časové okno: during first day of life
The participants were recorded by gestational age et birth
during first day of life
Neonatal outcome 2, based on maturation of neonates
Časové okno: during first day of life
Neonates were investigatied by maturation ( gestational age before 36+6 week) (prematurity
during first day of life
Neonatal outcome 3, (birth weight of newborns)
Časové okno: during first day of life
Neonates birth weight calculation (gram)
during first day of life
Neonatal outcome 4; Apgar score
Časové okno: during first day of life
Neonates poor adaptation status (Apgar score (<7) at 5 minutes)
during first day of life
Neonatal outcome 5, (umbilical cord pH)
Časové okno: during first day of life
Neonates poor adaptation status (umbilical cord pH <7.2)
during first day of life
Neonatal outcome 6; delivery complication
Časové okno: during first day of life
Delivery complication ( cesarean section due to fetal distress)
during first day of life
Neonatal outcome 7, necessary of intensive care unit
Časové okno: during first week of life
Neonates transfer to neonatal intensive care unit (NICU)
during first week of life

Sekundární výstupní opatření

Měření výsledku
Popis opatření
Časové okno
2D ultrasound investigaiotn of gestation (fetal biometry, placentation)
Časové okno: during prenatal care till the labour
Routine ultrasound examination, based on Guideline of Hungarian Obstetrics and gynecologists (fetal biometry: biparietal diameter, head circumference, abdominal circumference, femur length; investigation of the placenta, place of placentation, Grannum staging)
during prenatal care till the labour

Spolupracovníci a vyšetřovatelé

Zde najdete lidi a organizace zapojené do této studie.

Vyšetřovatelé

  • Studijní židle: Tibor Wittman, Professor, ALBERT SZENT-GYÖRGYI CLINICAL CENTER. REGIONAL SCIENTIFIC AND RESEARCH COMMITTEE FOR HUMAN BIOLOGICAL SCIENCE.

Publikace a užitečné odkazy

Osoba odpovědná za zadávání informací o studiu tyto publikace poskytuje dobrovolně. Mohou se týkat čehokoli, co souvisí se studiem.

Obecné publikace

Užitečné odkazy

Termíny studijních záznamů

Tato data sledují průběh záznamů studie a předkládání souhrnných výsledků na ClinicalTrials.gov. Záznamy ze studií a hlášené výsledky jsou před zveřejněním na veřejné webové stránce přezkoumány Národní lékařskou knihovnou (NLM), aby se ujistily, že splňují specifické standardy kontroly kvality.

Hlavní termíny studia

Začátek studia (Aktuální)

1. ledna 2018

Primární dokončení (Aktuální)

1. ledna 2020

Dokončení studie (Aktuální)

1. ledna 2021

Termíny zápisu do studia

První předloženo

1. prosince 2021

První předloženo, které splnilo kritéria kontroly kvality

16. února 2022

První zveřejněno (Aktuální)

17. února 2022

Aktualizace studijních záznamů

Poslední zveřejněná aktualizace (Aktuální)

17. února 2022

Odeslaná poslední aktualizace, která splnila kritéria kontroly kvality

16. února 2022

Naposledy ověřeno

1. února 2022

Více informací

Termíny související s touto studií

Další relevantní podmínky MeSH

Další identifikační čísla studie

  • 120/2015

Informace o lécích a zařízeních, studijní dokumenty

Studuje lékový produkt regulovaný americkým FDA

Ne

Studuje produkt zařízení regulovaný americkým úřadem FDA

Ne

produkt vyrobený a vyvážený z USA

Ne

Tyto informace byly beze změn načteny přímo z webu clinicaltrials.gov. Máte-li jakékoli požadavky na změnu, odstranění nebo aktualizaci podrobností studie, kontaktujte prosím register@clinicaltrials.gov. Jakmile bude změna implementována na clinicaltrials.gov, bude automaticky aktualizována i na našem webu .