- ICH GCP
- Registro de ensayos clínicos de EE. UU.
- Ensayo clínico NCT05245279
Placental Perfusion in the Entire Placenta and With Sonobiopsy by Ultrasound
16 de febrero de 2022 actualizado por: Andrea Suranyi, Szeged University
Correlation Between the Placental Perfusion Measured in the Entire Placenta and With Sonobiopsy
In this study is tested the validity of placental vascular indices obtained from placenta ultrasonographic sphere biopsy and entire placenta investigation.
Descripción general del estudio
Estado
Terminado
Condiciones
Descripción detallada
Although, to this date, there have been a number of human placental studies that concerned the evaluation of placental 3 dimensional power Doppler vascularization with the use of VOCAL technique, but there was no one in which placental vasculature has been compared between the sonobiopsy and whole placental volume.
Tipo de estudio
Intervencionista
Inscripción (Actual)
150
Fase
- No aplica
Contactos y Ubicaciones
Esta sección proporciona los datos de contacto de quienes realizan el estudio e información sobre dónde se lleva a cabo este estudio.
Ubicaciones de estudio
-
-
-
Szeged, Hungría, 6720
- Universitiy of Szeged
-
-
Criterios de participación
Los investigadores buscan personas que se ajusten a una determinada descripción, denominada criterio de elegibilidad. Algunos ejemplos de estos criterios son el estado de salud general de una persona o tratamientos previos.
Criterio de elegibilidad
Edades elegibles para estudiar
18 años a 45 años (Adulto)
Acepta Voluntarios Saludables
No
Géneros elegibles para el estudio
Femenino
Descripción
Exclusion criteria:
- multiple pregnancy,
- abnormal (> 3mm) nuchal translucency from 11+0 to 13+6 weeks of gestation,
- the fetal or neonatal structural or chromosomal anomaly,
- inadequate localization of the placenta (placenta praevia),
- self-reported drugs, alcohol, caffeine or nicotine abuse,
- exposed to circulatory medication (oxerutins, calcium dobesilate)
- or not signing the consent form.
- If the mother suffer from er systemic disease (e.g. diabetes, autoimmune disease, vasculitis, haemophilia, thrombophilia, HIV infection, etc)
Inclusion clriteria:
- single pregnancy
- healthy pregnant women
- no anatomical alteration of fetus
- no genetical abnormality of fetus
Plan de estudios
Esta sección proporciona detalles del plan de estudio, incluido cómo está diseñado el estudio y qué mide el estudio.
¿Cómo está diseñado el estudio?
Detalles de diseño
- Propósito principal: Diagnóstico
- Asignación: No aleatorizado
- Modelo Intervencionista: Asignación paralela
- Enmascaramiento: Ninguno (etiqueta abierta)
Armas e Intervenciones
Grupo de participantes/brazo |
Intervención / Tratamiento |
|---|---|
|
Experimental: Normal placenta-entitle
The 3-DPD indices was measured in the entire placenta volume.
|
Images that contributed to the determination of placental volume and 3-DPD indices were obtained at the time of visit.
All 3-D scans ultrasound measurements were performed by a Voluson 730 Expert ultrasound machine equipped with a multifrequency probe (2-5 MHz) to acquire images.
Each sample was examined using 3-D rendering mode, in which the colour and gray value information was processed and combined to supply 3-D image.
For laterally located placentas, the investigator positioned the transducer on a slight lateral inclination to obtain proper images.
Power Doppler window was placed over the placenta to map the vascular tree from basal to chorionic plates.
The 3-D static volume box was placed over the entire placenta volume.
The sweep angle was set at maximum 70°.
Each image was recovered from the disk in succession for processing.
During gestation, the investigator recorded one sample from each patient.
The two-dimensional (2-D) transabdominal conventional study provided data about fetal position, biometry, body movements and fetal heart rate as well as placental localization.
The factorial default setting 'Obstetrics' was applied in 2-D mode.
|
|
Experimental: Normal placenta-sonobyopsy
The 3-DPD indices was measured at cord insertion in placenta by sonobiopsy
|
Images that contributed to the determination of placental volume and 3-DPD indices were obtained at the time of visit.
All 3-D scans ultrasound measurements were performed by a Voluson 730 Expert ultrasound machine equipped with a multifrequency probe (2-5 MHz) to acquire images.
Each sample was examined using 3-D rendering mode, in which the colour and gray value information was processed and combined to supply 3-D image.
For laterally located placentas, the investigator positioned the transducer on a slight lateral inclination to obtain proper images.
Power Doppler window was placed over the placenta to map the vascular tree from basal to chorionic plates.
The 3-D static volume box was placed over the entire placenta volume.
The sweep angle was set at maximum 70°.
Each image was recovered from the disk in succession for processing.
During gestation, the investigator recorded one sample from each patient.
The two-dimensional (2-D) transabdominal conventional study provided data about fetal position, biometry, body movements and fetal heart rate as well as placental localization.
The factorial default setting 'Obstetrics' was applied in 2-D mode.
|
¿Qué mide el estudio?
Medidas de resultado primarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
|---|---|---|
|
Maternal characteristics (BMI)
Periodo de tiempo: through study completion, 2 years
|
The pre-pregnancy body mass index (BMI) registered at the initial visit during prenatal care was calculated as the body weight (kg) per height (m2).
|
through study completion, 2 years
|
|
Neonatal outcome 1; based on gestational age
Periodo de tiempo: during first day of life
|
The participants were recorded by gestational age et birth
|
during first day of life
|
|
Neonatal outcome 2, based on maturation of neonates
Periodo de tiempo: during first day of life
|
Neonates were investigatied by maturation ( gestational age before 36+6 week) (prematurity
|
during first day of life
|
|
Neonatal outcome 3, (birth weight of newborns)
Periodo de tiempo: during first day of life
|
Neonates birth weight calculation (gram)
|
during first day of life
|
|
Neonatal outcome 4; Apgar score
Periodo de tiempo: during first day of life
|
Neonates poor adaptation status (Apgar score (<7) at 5 minutes)
|
during first day of life
|
|
Neonatal outcome 5, (umbilical cord pH)
Periodo de tiempo: during first day of life
|
Neonates poor adaptation status (umbilical cord pH <7.2)
|
during first day of life
|
|
Neonatal outcome 6; delivery complication
Periodo de tiempo: during first day of life
|
Delivery complication ( cesarean section due to fetal distress)
|
during first day of life
|
|
Neonatal outcome 7, necessary of intensive care unit
Periodo de tiempo: during first week of life
|
Neonates transfer to neonatal intensive care unit (NICU)
|
during first week of life
|
Medidas de resultado secundarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
|---|---|---|
|
2D ultrasound investigaiotn of gestation (fetal biometry, placentation)
Periodo de tiempo: during prenatal care till the labour
|
Routine ultrasound examination, based on Guideline of Hungarian Obstetrics and gynecologists (fetal biometry: biparietal diameter, head circumference, abdominal circumference, femur length; investigation of the placenta, place of placentation, Grannum staging)
|
during prenatal care till the labour
|
Colaboradores e Investigadores
Aquí es donde encontrará personas y organizaciones involucradas en este estudio.
Patrocinador
Investigadores
- Silla de estudio: Tibor Wittman, Professor, ALBERT SZENT-GYÖRGYI CLINICAL CENTER. REGIONAL SCIENTIFIC AND RESEARCH COMMITTEE FOR HUMAN BIOLOGICAL SCIENCE.
Publicaciones y enlaces útiles
La persona responsable de ingresar información sobre el estudio proporciona voluntariamente estas publicaciones. Estos pueden ser sobre cualquier cosa relacionada con el estudio.
Publicaciones Generales
- Odibo AO, Zhong Y, Longtine M, Tuuli M, Odibo L, Cahill AG, Macones GA, Nelson DM. First-trimester serum analytes, biophysical tests and the association with pathological morphometry in the placenta of pregnancies with preeclampsia and fetal growth restriction. Placenta. 2011 Apr;32(4):333-8. doi: 10.1016/j.placenta.2011.01.016. Epub 2011 Feb 13.
- Molnar A, Suranyi A, Jako M, Nyari T, Nemeth G. [Examination of placental three-dimensional power Doppler indices and perinatal outcome in pregnancies complicated by intrauterine growth restriction]. Orv Hetil. 2017 Jul;158(26):1008-1013. doi: 10.1556/650.2017.30784. Hungarian.
- Kozinszky Z, Suranyi A, Peics H, Molnar A, Pal A. Placental Volumetry by 2-D Sonography with a New Mathematical Formula: Prospective Study on the Shell of a Spherical Sector Model. Ultrasound Med Biol. 2015 Aug;41(8):2252-8. doi: 10.1016/j.ultrasmedbio.2015.04.005. Epub 2015 May 7.
- Collins SL, Stevenson GN, Noble JA, Impey L. Rapid calculation of standardized placental volume at 11 to 13 weeks and the prediction of small for gestational age babies. Ultrasound Med Biol. 2013 Feb;39(2):253-60. doi: 10.1016/j.ultrasmedbio.2012.09.003. Epub 2012 Dec 4.
- Moran M, McAuliffe FM. Imaging and assessment of placental function. J Clin Ultrasound. 2011 Sep;39(7):390-8. doi: 10.1002/jcu.20846. Epub 2011 Jun 8.
- Plasencia W, Akolekar R, Dagklis T, Veduta A, Nicolaides KH. Placental volume at 11-13 weeks' gestation in the prediction of birth weight percentile. Fetal Diagn Ther. 2011;30(1):23-8. doi: 10.1159/000324318. Epub 2011 Jun 23.
- Merce LT, Barco MJ, Bau S. Reproducibility of the study of placental vascularization by three-dimensional power Doppler. J Perinat Med. 2004;32(3):228-33. doi: 10.1515/JPM.2004.043.
Enlaces Útiles
- First trimester placental and myometrial blood perfusion measured by 3D power Doppler in normal and unfavourable outcome pregnancies
- Matijevic R, Kurjak A. The assessment of placental blood vessels by three-dimensional power Doppler ultrasound
- Odibo AO, Goetzinger KR, Huster KM, Christiansen JK, Odibo L, Tuuli MG. Placental volume and vascular flow assessed by 3D power Doppler and adverse pregnancy outcomes
- Pairleitner H, Steiner H, Hasenoehrl G, Staudach A. Three-dimensional power Doppler sonography: imaging and quantifying blood flow and vascularization
- Tuuli MG, Houser M, Odibo L, Huster K, Macones GA, Odibo AO. Validation of placental vascular sonobiopsy for obtaining representative placental vascular indices by three-dimensional power Doppler ultrasonography
- Evaluation of placental vascularization by three-dimensional ultrasound examination in second and third trimester of pregnancies complicated by chronic hypertension, gestational hypertension or pre-eclampsia
- Surányi A, Kozinszky Z, Molnár A, Németh G. Placental volume relative to fetal weight estimated by sonography in diabetic pregnancies
- Demers S, Boutin A, Dembickaja R, Campanero M, Nicolaides K. Factors Associated with Placental Vascularization Measured by 3D Power Doppler Ultrasonographic Sphere Biopsy between 11 and 14 Weeks of Gestation
- Demers S, Girard M, Roberge S, Tetu A, Giguere Y, Forest J-C, et al. First-Trimester Placental and Myometrial Blood Perfusion Measured by Three-Dimensional Power Doppler in Preeclampsia
Fechas de registro del estudio
Estas fechas rastrean el progreso del registro del estudio y los envíos de resultados resumidos a ClinicalTrials.gov. Los registros del estudio y los resultados informados son revisados por la Biblioteca Nacional de Medicina (NLM) para asegurarse de que cumplan con los estándares de control de calidad específicos antes de publicarlos en el sitio web público.
Fechas importantes del estudio
Inicio del estudio (Actual)
1 de enero de 2018
Finalización primaria (Actual)
1 de enero de 2020
Finalización del estudio (Actual)
1 de enero de 2021
Fechas de registro del estudio
Enviado por primera vez
1 de diciembre de 2021
Primero enviado que cumplió con los criterios de control de calidad
16 de febrero de 2022
Publicado por primera vez (Actual)
17 de febrero de 2022
Actualizaciones de registros de estudio
Última actualización publicada (Actual)
17 de febrero de 2022
Última actualización enviada que cumplió con los criterios de control de calidad
16 de febrero de 2022
Última verificación
1 de febrero de 2022
Más información
Términos relacionados con este estudio
Términos MeSH relevantes adicionales
Otros números de identificación del estudio
- 120/2015
Información sobre medicamentos y dispositivos, documentos del estudio
Estudia un producto farmacéutico regulado por la FDA de EE. UU.
No
Estudia un producto de dispositivo regulado por la FDA de EE. UU.
No
producto fabricado y exportado desde los EE. UU.
No
Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .