Cette page a été traduite automatiquement et l'exactitude de la traduction n'est pas garantie. Veuillez vous référer au version anglaise pour un texte source.

Placental Perfusion in the Entire Placenta and With Sonobiopsy by Ultrasound

16 février 2022 mis à jour par: Andrea Suranyi, Szeged University

Correlation Between the Placental Perfusion Measured in the Entire Placenta and With Sonobiopsy

In this study is tested the validity of placental vascular indices obtained from placenta ultrasonographic sphere biopsy and entire placenta investigation.

Aperçu de l'étude

Description détaillée

Although, to this date, there have been a number of human placental studies that concerned the evaluation of placental 3 dimensional power Doppler vascularization with the use of VOCAL technique, but there was no one in which placental vasculature has been compared between the sonobiopsy and whole placental volume.

Type d'étude

Interventionnel

Inscription (Réel)

150

Phase

  • N'est pas applicable

Contacts et emplacements

Cette section fournit les coordonnées de ceux qui mènent l'étude et des informations sur le lieu où cette étude est menée.

Lieux d'étude

      • Szeged, Hongrie, 6720
        • Universitiy of Szeged

Critères de participation

Les chercheurs recherchent des personnes qui correspondent à une certaine description, appelée critères d'éligibilité. Certains exemples de ces critères sont l'état de santé général d'une personne ou des traitements antérieurs.

Critère d'éligibilité

Âges éligibles pour étudier

18 ans à 45 ans (Adulte)

Accepte les volontaires sains

Non

Sexes éligibles pour l'étude

Femelle

La description

Exclusion criteria:

  • multiple pregnancy,
  • abnormal (> 3mm) nuchal translucency from 11+0 to 13+6 weeks of gestation,
  • the fetal or neonatal structural or chromosomal anomaly,
  • inadequate localization of the placenta (placenta praevia),
  • self-reported drugs, alcohol, caffeine or nicotine abuse,
  • exposed to circulatory medication (oxerutins, calcium dobesilate)
  • or not signing the consent form.
  • If the mother suffer from er systemic disease (e.g. diabetes, autoimmune disease, vasculitis, haemophilia, thrombophilia, HIV infection, etc)

Inclusion clriteria:

  • single pregnancy
  • healthy pregnant women
  • no anatomical alteration of fetus
  • no genetical abnormality of fetus

Plan d'étude

Cette section fournit des détails sur le plan d'étude, y compris la façon dont l'étude est conçue et ce que l'étude mesure.

Comment l'étude est-elle conçue ?

Détails de conception

  • Objectif principal: Diagnostique
  • Répartition: Non randomisé
  • Modèle interventionnel: Affectation parallèle
  • Masquage: Aucun (étiquette ouverte)

Armes et Interventions

Groupe de participants / Bras
Intervention / Traitement
Expérimental: Normal placenta-entitle
The 3-DPD indices was measured in the entire placenta volume.
Images that contributed to the determination of placental volume and 3-DPD indices were obtained at the time of visit. All 3-D scans ultrasound measurements were performed by a Voluson 730 Expert ultrasound machine equipped with a multifrequency probe (2-5 MHz) to acquire images. Each sample was examined using 3-D rendering mode, in which the colour and gray value information was processed and combined to supply 3-D image. For laterally located placentas, the investigator positioned the transducer on a slight lateral inclination to obtain proper images. Power Doppler window was placed over the placenta to map the vascular tree from basal to chorionic plates. The 3-D static volume box was placed over the entire placenta volume. The sweep angle was set at maximum 70°. Each image was recovered from the disk in succession for processing. During gestation, the investigator recorded one sample from each patient.
The two-dimensional (2-D) transabdominal conventional study provided data about fetal position, biometry, body movements and fetal heart rate as well as placental localization. The factorial default setting 'Obstetrics' was applied in 2-D mode.
Expérimental: Normal placenta-sonobyopsy
The 3-DPD indices was measured at cord insertion in placenta by sonobiopsy
Images that contributed to the determination of placental volume and 3-DPD indices were obtained at the time of visit. All 3-D scans ultrasound measurements were performed by a Voluson 730 Expert ultrasound machine equipped with a multifrequency probe (2-5 MHz) to acquire images. Each sample was examined using 3-D rendering mode, in which the colour and gray value information was processed and combined to supply 3-D image. For laterally located placentas, the investigator positioned the transducer on a slight lateral inclination to obtain proper images. Power Doppler window was placed over the placenta to map the vascular tree from basal to chorionic plates. The 3-D static volume box was placed over the entire placenta volume. The sweep angle was set at maximum 70°. Each image was recovered from the disk in succession for processing. During gestation, the investigator recorded one sample from each patient.
The two-dimensional (2-D) transabdominal conventional study provided data about fetal position, biometry, body movements and fetal heart rate as well as placental localization. The factorial default setting 'Obstetrics' was applied in 2-D mode.

Que mesure l'étude ?

Principaux critères de jugement

Mesure des résultats
Description de la mesure
Délai
Maternal characteristics (BMI)
Délai: through study completion, 2 years
The pre-pregnancy body mass index (BMI) registered at the initial visit during prenatal care was calculated as the body weight (kg) per height (m2).
through study completion, 2 years
Neonatal outcome 1; based on gestational age
Délai: during first day of life
The participants were recorded by gestational age et birth
during first day of life
Neonatal outcome 2, based on maturation of neonates
Délai: during first day of life
Neonates were investigatied by maturation ( gestational age before 36+6 week) (prematurity
during first day of life
Neonatal outcome 3, (birth weight of newborns)
Délai: during first day of life
Neonates birth weight calculation (gram)
during first day of life
Neonatal outcome 4; Apgar score
Délai: during first day of life
Neonates poor adaptation status (Apgar score (<7) at 5 minutes)
during first day of life
Neonatal outcome 5, (umbilical cord pH)
Délai: during first day of life
Neonates poor adaptation status (umbilical cord pH <7.2)
during first day of life
Neonatal outcome 6; delivery complication
Délai: during first day of life
Delivery complication ( cesarean section due to fetal distress)
during first day of life
Neonatal outcome 7, necessary of intensive care unit
Délai: during first week of life
Neonates transfer to neonatal intensive care unit (NICU)
during first week of life

Mesures de résultats secondaires

Mesure des résultats
Description de la mesure
Délai
2D ultrasound investigaiotn of gestation (fetal biometry, placentation)
Délai: during prenatal care till the labour
Routine ultrasound examination, based on Guideline of Hungarian Obstetrics and gynecologists (fetal biometry: biparietal diameter, head circumference, abdominal circumference, femur length; investigation of the placenta, place of placentation, Grannum staging)
during prenatal care till the labour

Collaborateurs et enquêteurs

C'est ici que vous trouverez les personnes et les organisations impliquées dans cette étude.

Parrainer

Les enquêteurs

  • Chaise d'étude: Tibor Wittman, Professor, ALBERT SZENT-GYÖRGYI CLINICAL CENTER. REGIONAL SCIENTIFIC AND RESEARCH COMMITTEE FOR HUMAN BIOLOGICAL SCIENCE.

Publications et liens utiles

La personne responsable de la saisie des informations sur l'étude fournit volontairement ces publications. Il peut s'agir de tout ce qui concerne l'étude.

Publications générales

Liens utiles

Dates d'enregistrement des études

Ces dates suivent la progression des dossiers d'étude et des soumissions de résultats sommaires à ClinicalTrials.gov. Les dossiers d'étude et les résultats rapportés sont examinés par la Bibliothèque nationale de médecine (NLM) pour s'assurer qu'ils répondent à des normes de contrôle de qualité spécifiques avant d'être publiés sur le site Web public.

Dates principales de l'étude

Début de l'étude (Réel)

1 janvier 2018

Achèvement primaire (Réel)

1 janvier 2020

Achèvement de l'étude (Réel)

1 janvier 2021

Dates d'inscription aux études

Première soumission

1 décembre 2021

Première soumission répondant aux critères de contrôle qualité

16 février 2022

Première publication (Réel)

17 février 2022

Mises à jour des dossiers d'étude

Dernière mise à jour publiée (Réel)

17 février 2022

Dernière mise à jour soumise répondant aux critères de contrôle qualité

16 février 2022

Dernière vérification

1 février 2022

Plus d'information

Termes liés à cette étude

Termes MeSH pertinents supplémentaires

Autres numéros d'identification d'étude

  • 120/2015

Informations sur les médicaments et les dispositifs, documents d'étude

Étudie un produit pharmaceutique réglementé par la FDA américaine

Non

Étudie un produit d'appareil réglementé par la FDA américaine

Non

produit fabriqué et exporté des États-Unis.

Non

Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .

S'abonner