- ICH GCP
- Registre américain des essais cliniques
- Essai clinique NCT05245279
Placental Perfusion in the Entire Placenta and With Sonobiopsy by Ultrasound
16 février 2022 mis à jour par: Andrea Suranyi, Szeged University
Correlation Between the Placental Perfusion Measured in the Entire Placenta and With Sonobiopsy
In this study is tested the validity of placental vascular indices obtained from placenta ultrasonographic sphere biopsy and entire placenta investigation.
Aperçu de l'étude
Statut
Complété
Les conditions
Description détaillée
Although, to this date, there have been a number of human placental studies that concerned the evaluation of placental 3 dimensional power Doppler vascularization with the use of VOCAL technique, but there was no one in which placental vasculature has been compared between the sonobiopsy and whole placental volume.
Type d'étude
Interventionnel
Inscription (Réel)
150
Phase
- N'est pas applicable
Contacts et emplacements
Cette section fournit les coordonnées de ceux qui mènent l'étude et des informations sur le lieu où cette étude est menée.
Lieux d'étude
-
-
-
Szeged, Hongrie, 6720
- Universitiy of Szeged
-
-
Critères de participation
Les chercheurs recherchent des personnes qui correspondent à une certaine description, appelée critères d'éligibilité. Certains exemples de ces critères sont l'état de santé général d'une personne ou des traitements antérieurs.
Critère d'éligibilité
Âges éligibles pour étudier
18 ans à 45 ans (Adulte)
Accepte les volontaires sains
Non
Sexes éligibles pour l'étude
Femelle
La description
Exclusion criteria:
- multiple pregnancy,
- abnormal (> 3mm) nuchal translucency from 11+0 to 13+6 weeks of gestation,
- the fetal or neonatal structural or chromosomal anomaly,
- inadequate localization of the placenta (placenta praevia),
- self-reported drugs, alcohol, caffeine or nicotine abuse,
- exposed to circulatory medication (oxerutins, calcium dobesilate)
- or not signing the consent form.
- If the mother suffer from er systemic disease (e.g. diabetes, autoimmune disease, vasculitis, haemophilia, thrombophilia, HIV infection, etc)
Inclusion clriteria:
- single pregnancy
- healthy pregnant women
- no anatomical alteration of fetus
- no genetical abnormality of fetus
Plan d'étude
Cette section fournit des détails sur le plan d'étude, y compris la façon dont l'étude est conçue et ce que l'étude mesure.
Comment l'étude est-elle conçue ?
Détails de conception
- Objectif principal: Diagnostique
- Répartition: Non randomisé
- Modèle interventionnel: Affectation parallèle
- Masquage: Aucun (étiquette ouverte)
Armes et Interventions
Groupe de participants / Bras |
Intervention / Traitement |
|---|---|
|
Expérimental: Normal placenta-entitle
The 3-DPD indices was measured in the entire placenta volume.
|
Images that contributed to the determination of placental volume and 3-DPD indices were obtained at the time of visit.
All 3-D scans ultrasound measurements were performed by a Voluson 730 Expert ultrasound machine equipped with a multifrequency probe (2-5 MHz) to acquire images.
Each sample was examined using 3-D rendering mode, in which the colour and gray value information was processed and combined to supply 3-D image.
For laterally located placentas, the investigator positioned the transducer on a slight lateral inclination to obtain proper images.
Power Doppler window was placed over the placenta to map the vascular tree from basal to chorionic plates.
The 3-D static volume box was placed over the entire placenta volume.
The sweep angle was set at maximum 70°.
Each image was recovered from the disk in succession for processing.
During gestation, the investigator recorded one sample from each patient.
The two-dimensional (2-D) transabdominal conventional study provided data about fetal position, biometry, body movements and fetal heart rate as well as placental localization.
The factorial default setting 'Obstetrics' was applied in 2-D mode.
|
|
Expérimental: Normal placenta-sonobyopsy
The 3-DPD indices was measured at cord insertion in placenta by sonobiopsy
|
Images that contributed to the determination of placental volume and 3-DPD indices were obtained at the time of visit.
All 3-D scans ultrasound measurements were performed by a Voluson 730 Expert ultrasound machine equipped with a multifrequency probe (2-5 MHz) to acquire images.
Each sample was examined using 3-D rendering mode, in which the colour and gray value information was processed and combined to supply 3-D image.
For laterally located placentas, the investigator positioned the transducer on a slight lateral inclination to obtain proper images.
Power Doppler window was placed over the placenta to map the vascular tree from basal to chorionic plates.
The 3-D static volume box was placed over the entire placenta volume.
The sweep angle was set at maximum 70°.
Each image was recovered from the disk in succession for processing.
During gestation, the investigator recorded one sample from each patient.
The two-dimensional (2-D) transabdominal conventional study provided data about fetal position, biometry, body movements and fetal heart rate as well as placental localization.
The factorial default setting 'Obstetrics' was applied in 2-D mode.
|
Que mesure l'étude ?
Principaux critères de jugement
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
Maternal characteristics (BMI)
Délai: through study completion, 2 years
|
The pre-pregnancy body mass index (BMI) registered at the initial visit during prenatal care was calculated as the body weight (kg) per height (m2).
|
through study completion, 2 years
|
|
Neonatal outcome 1; based on gestational age
Délai: during first day of life
|
The participants were recorded by gestational age et birth
|
during first day of life
|
|
Neonatal outcome 2, based on maturation of neonates
Délai: during first day of life
|
Neonates were investigatied by maturation ( gestational age before 36+6 week) (prematurity
|
during first day of life
|
|
Neonatal outcome 3, (birth weight of newborns)
Délai: during first day of life
|
Neonates birth weight calculation (gram)
|
during first day of life
|
|
Neonatal outcome 4; Apgar score
Délai: during first day of life
|
Neonates poor adaptation status (Apgar score (<7) at 5 minutes)
|
during first day of life
|
|
Neonatal outcome 5, (umbilical cord pH)
Délai: during first day of life
|
Neonates poor adaptation status (umbilical cord pH <7.2)
|
during first day of life
|
|
Neonatal outcome 6; delivery complication
Délai: during first day of life
|
Delivery complication ( cesarean section due to fetal distress)
|
during first day of life
|
|
Neonatal outcome 7, necessary of intensive care unit
Délai: during first week of life
|
Neonates transfer to neonatal intensive care unit (NICU)
|
during first week of life
|
Mesures de résultats secondaires
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
2D ultrasound investigaiotn of gestation (fetal biometry, placentation)
Délai: during prenatal care till the labour
|
Routine ultrasound examination, based on Guideline of Hungarian Obstetrics and gynecologists (fetal biometry: biparietal diameter, head circumference, abdominal circumference, femur length; investigation of the placenta, place of placentation, Grannum staging)
|
during prenatal care till the labour
|
Collaborateurs et enquêteurs
C'est ici que vous trouverez les personnes et les organisations impliquées dans cette étude.
Parrainer
Les enquêteurs
- Chaise d'étude: Tibor Wittman, Professor, ALBERT SZENT-GYÖRGYI CLINICAL CENTER. REGIONAL SCIENTIFIC AND RESEARCH COMMITTEE FOR HUMAN BIOLOGICAL SCIENCE.
Publications et liens utiles
La personne responsable de la saisie des informations sur l'étude fournit volontairement ces publications. Il peut s'agir de tout ce qui concerne l'étude.
Publications générales
- Odibo AO, Zhong Y, Longtine M, Tuuli M, Odibo L, Cahill AG, Macones GA, Nelson DM. First-trimester serum analytes, biophysical tests and the association with pathological morphometry in the placenta of pregnancies with preeclampsia and fetal growth restriction. Placenta. 2011 Apr;32(4):333-8. doi: 10.1016/j.placenta.2011.01.016. Epub 2011 Feb 13.
- Molnar A, Suranyi A, Jako M, Nyari T, Nemeth G. [Examination of placental three-dimensional power Doppler indices and perinatal outcome in pregnancies complicated by intrauterine growth restriction]. Orv Hetil. 2017 Jul;158(26):1008-1013. doi: 10.1556/650.2017.30784. Hungarian.
- Kozinszky Z, Suranyi A, Peics H, Molnar A, Pal A. Placental Volumetry by 2-D Sonography with a New Mathematical Formula: Prospective Study on the Shell of a Spherical Sector Model. Ultrasound Med Biol. 2015 Aug;41(8):2252-8. doi: 10.1016/j.ultrasmedbio.2015.04.005. Epub 2015 May 7.
- Collins SL, Stevenson GN, Noble JA, Impey L. Rapid calculation of standardized placental volume at 11 to 13 weeks and the prediction of small for gestational age babies. Ultrasound Med Biol. 2013 Feb;39(2):253-60. doi: 10.1016/j.ultrasmedbio.2012.09.003. Epub 2012 Dec 4.
- Moran M, McAuliffe FM. Imaging and assessment of placental function. J Clin Ultrasound. 2011 Sep;39(7):390-8. doi: 10.1002/jcu.20846. Epub 2011 Jun 8.
- Plasencia W, Akolekar R, Dagklis T, Veduta A, Nicolaides KH. Placental volume at 11-13 weeks' gestation in the prediction of birth weight percentile. Fetal Diagn Ther. 2011;30(1):23-8. doi: 10.1159/000324318. Epub 2011 Jun 23.
- Merce LT, Barco MJ, Bau S. Reproducibility of the study of placental vascularization by three-dimensional power Doppler. J Perinat Med. 2004;32(3):228-33. doi: 10.1515/JPM.2004.043.
Liens utiles
- First trimester placental and myometrial blood perfusion measured by 3D power Doppler in normal and unfavourable outcome pregnancies
- Matijevic R, Kurjak A. The assessment of placental blood vessels by three-dimensional power Doppler ultrasound
- Odibo AO, Goetzinger KR, Huster KM, Christiansen JK, Odibo L, Tuuli MG. Placental volume and vascular flow assessed by 3D power Doppler and adverse pregnancy outcomes
- Pairleitner H, Steiner H, Hasenoehrl G, Staudach A. Three-dimensional power Doppler sonography: imaging and quantifying blood flow and vascularization
- Tuuli MG, Houser M, Odibo L, Huster K, Macones GA, Odibo AO. Validation of placental vascular sonobiopsy for obtaining representative placental vascular indices by three-dimensional power Doppler ultrasonography
- Evaluation of placental vascularization by three-dimensional ultrasound examination in second and third trimester of pregnancies complicated by chronic hypertension, gestational hypertension or pre-eclampsia
- Surányi A, Kozinszky Z, Molnár A, Németh G. Placental volume relative to fetal weight estimated by sonography in diabetic pregnancies
- Demers S, Boutin A, Dembickaja R, Campanero M, Nicolaides K. Factors Associated with Placental Vascularization Measured by 3D Power Doppler Ultrasonographic Sphere Biopsy between 11 and 14 Weeks of Gestation
- Demers S, Girard M, Roberge S, Tetu A, Giguere Y, Forest J-C, et al. First-Trimester Placental and Myometrial Blood Perfusion Measured by Three-Dimensional Power Doppler in Preeclampsia
Dates d'enregistrement des études
Ces dates suivent la progression des dossiers d'étude et des soumissions de résultats sommaires à ClinicalTrials.gov. Les dossiers d'étude et les résultats rapportés sont examinés par la Bibliothèque nationale de médecine (NLM) pour s'assurer qu'ils répondent à des normes de contrôle de qualité spécifiques avant d'être publiés sur le site Web public.
Dates principales de l'étude
Début de l'étude (Réel)
1 janvier 2018
Achèvement primaire (Réel)
1 janvier 2020
Achèvement de l'étude (Réel)
1 janvier 2021
Dates d'inscription aux études
Première soumission
1 décembre 2021
Première soumission répondant aux critères de contrôle qualité
16 février 2022
Première publication (Réel)
17 février 2022
Mises à jour des dossiers d'étude
Dernière mise à jour publiée (Réel)
17 février 2022
Dernière mise à jour soumise répondant aux critères de contrôle qualité
16 février 2022
Dernière vérification
1 février 2022
Plus d'information
Termes liés à cette étude
Termes MeSH pertinents supplémentaires
Autres numéros d'identification d'étude
- 120/2015
Informations sur les médicaments et les dispositifs, documents d'étude
Étudie un produit pharmaceutique réglementé par la FDA américaine
Non
Étudie un produit d'appareil réglementé par la FDA américaine
Non
produit fabriqué et exporté des États-Unis.
Non
Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .