Tato stránka byla automaticky přeložena a přesnost překladu není zaručena. Podívejte se prosím na anglická verze pro zdrojový text.

Withings Hypertension Notification Retrospective Study (HTNF)

3. června 2026 aktualizováno: Withings

Validation of the Withings Hypertension Notification Feature (HTNF): A Retrospective Study Comparing Diagnostic Performance Against the FDA-Authorized Predicate Device (Apple Watch HTNF, K250507)

This retrospective, non-interventional clinical investigation evaluates the diagnostic performance of the Withings Hypertension Notification Feature (HTNF), a software-only medical device (SaMD) that analyzes demographic, anthropometric, and physiological parameters collected by Withings connected smart scales to identify patterns suggestive of hypertension. Ground-truth blood pressure measurements are obtained concurrently from Withings connected blood pressure monitors. The study tests whether the Withings HTNF achieves diagnostic performance substantially equivalent to the FDA-authorized predicate device (Apple Watch HTNF, K250507) for the purpose of 510(k) clearance.

Přehled studie

Detailní popis

Hypertension affects approximately 1.4 billion adults worldwide and is the leading modifiable risk factor for cardiovascular disease. In September 2025, the FDA granted 510(k) authorization (K250507) to Apple Inc. for a Hypertension Notification Feature on Apple Watch, establishing the first regulatory precedent for consumer wearable-based hypertension screening.

The Withings Hypertension Notification Feature (HTNF) is a software-only medical device (Software as a Medical Device, SaMD) that analyzes demographic, anthropometric, and physiological parameter data opportunistically collected by Withings connected smart scales to identify patterns suggestive of hypertension and provide a notification to the user. Ground-truth hypertension status is defined at the user-week level as a weekly average systolic blood pressure (SBP) >= 130 mmHg or diastolic blood pressure (DBP) >= 80 mmHg (2017 ACC/AHA guideline), based on a minimum of 7 weekly blood pressure measurements from Withings BPM devices.

The co-primary endpoints are the stage-adjusted sensitivity and stage-adjusted specificity of the Withings HTNF algorithm on a held-out validation set, evaluated via a conjunctive intersection-union test (IUT) at one-sided alpha = 0.025. Stage adjustment is performed via Direct Standardization to the predicate's stage distribution. Confidence intervals are derived using BCa bootstrap resampling with at least 10,000 replicates.

Secondary endpoints include stage-specific Se/Sp, PPV/NPV, AUC-ROC, subgroup performance (age, sex, BMI, race/ethnicity, device model, prior HTN diagnosis, antihypertensive medication), and time-to-first-false-positive analyses. For the US cohort, race, ethnicity, diagnosis, and medication history are obtained via linkage to the HealthVerity claims database.

Data were collected retrospectively between 2019 and 2026 from consumer users of commercially available Withings smart scales who received an information letter and did not opt out. No prospective measurements or interventions are performed.

Typ studie

Pozorovací

Zápis (Odhadovaný)

2500

Kontakty a umístění

Tato část poskytuje kontaktní údaje pro ty, kteří studii provádějí, a informace o tom, kde se tato studie provádí.

Studijní místa

    • Île-de-France Region
      • Issy-les-Moulineaux, Île-de-France Region, Francie, 92130
        • Withings SA

Kritéria účasti

Výzkumníci hledají lidi, kteří odpovídají určitému popisu, kterému se říká kritéria způsobilosti. Některé příklady těchto kritérií jsou celkový zdravotní stav osoby nebo předchozí léčba.

Kritéria způsobilosti

Věk způsobilý ke studiu

  • Dospělý
  • Starší dospělý

Přijímá zdravé dobrovolníky

Ano

Metoda odběru vzorků

Vzorek nepravděpodobnosti

Studijní populace

Adult consumer users (>= 18 years, >= 22 years in the US) of Withings connected smart scales (Body Cardio, Body Scan, Body Comp) with concurrent Withings connected blood pressure monitor data, who received the study information letter and did not opt out. The retrospective validation cohort is drawn from a HealthVerity-linked US subset to support subgroup analyses by race, ethnicity, prior hypertension diagnosis, and antihypertensive medication use.

Popis

Inclusion Criteria:

  • Users of commercially purchased, consumer-grade Withings smart scales (models Body Cardio, Body Comp, Body Scan) in a standard home environment
  • Concurrent ground-truth blood pressure data collected via Withings connected blood pressure monitors (BPM, BPM+, BPM Connect, or BPM Core)
  • At least 7 blood pressure measurements within a given week to establish reliable weekly hypertension status classification
  • Age >= 18 years (all regions) or >= 22 years (United States), consistent with the predicate device age requirement
  • Receipt of the study information letter without exercising the right to opt out (for applicable regulatory jurisdictions)

Exclusion Criteria:

  • Users lacking valid weekly average systolic and diastolic blood pressure measurements (missing ground truth)
  • Users with physiological measurements falling outside plausible clinical ranges (BMI < 10 or > 100 kg/m2, age < 18/22 or > 100 years)
  • Users who exercised their right to opt out of the retrospective study
  • Users without an individual Withings account (shared accounts are excluded to prevent data contamination)

Studijní plán

Tato část poskytuje podrobnosti o studijním plánu, včetně toho, jak je studie navržena a co studie měří.

Jak je studie koncipována?

Detaily designu

Kohorty a intervence

Skupina / kohorta
Intervence / Léčba
Withings Smart Scale Users
Retrospective cohort of adult consumer users of Withings connected smart scales (Body Cardio, Body Scan, Body Comp) with concurrent Withings blood pressure monitor measurements between 2019 and 2026. The held-out validation subset (~2,500 users) is drawn from the HealthVerity-linked US cohort to support stage-adjusted Sensitivity and Specificity primary endpoints and subgroup analyses.
Ground-truth weekly average systolic and diastolic blood pressure measurements obtained from Withings connected blood pressure monitors (BPM [WPM02], BPM+ [WPM03], BPM Core [WPM04], BPM Connect [WPM05]), validated as non-invasive oscillometric blood pressure monitors per ISO 81060-2:2018. Minimum 7 measurements per user-week required.
The Withings Hypertension Notification Feature (HTNF) is a software-only medical device (Software as a Medical Device, SaMD) that analyzes demographic, anthropometric, and physiological parameter data opportunistically collected by Withings connected smart scales to identify patterns suggestive of hypertension and provide a notification to the user.

Co je měření studie?

Primární výstupní opatření

Měření výsledku
Popis opatření
Časové okno
Stage-Adjusted Sensitivity (Se) of the Withings HTNF Algorithm
Časové okno: up to 7 years
Percentage of hypertensive user-weeks correctly flagged
up to 7 years
Stage-Adjusted Specificity (Sp) of the Withings HTNF Algorithm
Časové okno: up to 7 years
Percentage of non-hypertensive user-weeks correctly not flagged
up to 7 years

Spolupracovníci a vyšetřovatelé

Zde najdete lidi a organizace zapojené do této studie.

Sponzor

Vyšetřovatelé

  • Vrchní vyšetřovatel: Pierre Escourrou, MD, PhD, Centre Interdisciplinaire du Sommeil, Paris, France

Termíny studijních záznamů

Tato data sledují průběh záznamů studie a předkládání souhrnných výsledků na ClinicalTrials.gov. Záznamy ze studií a hlášené výsledky jsou před zveřejněním na veřejné webové stránce přezkoumány Národní lékařskou knihovnou (NLM), aby se ujistily, že splňují specifické standardy kontroly kvality.

Hlavní termíny studia

Začátek studia (Aktuální)

1. března 2026

Primární dokončení (Odhadovaný)

1. července 2026

Dokončení studie (Odhadovaný)

1. července 2026

Termíny zápisu do studia

První předloženo

26. května 2026

První předloženo, které splnilo kritéria kontroly kvality

3. června 2026

První zveřejněno (Aktuální)

8. června 2026

Aktualizace studijních záznamů

Poslední zveřejněná aktualizace (Aktuální)

8. června 2026

Odeslaná poslední aktualizace, která splnila kritéria kontroly kvality

3. června 2026

Naposledy ověřeno

1. června 2026

Více informací

Termíny související s touto studií

Plán pro data jednotlivých účastníků (IPD)

Plánujete sdílet data jednotlivých účastníků (IPD)?

NE

Informace o lécích a zařízeních, studijní dokumenty

Studuje lékový produkt regulovaný americkým FDA

Ne

Studuje produkt zařízení regulovaný americkým úřadem FDA

Ano

produkt vyrobený a vyvážený z USA

Ne

Tyto informace byly beze změn načteny přímo z webu clinicaltrials.gov. Máte-li jakékoli požadavky na změnu, odstranění nebo aktualizaci podrobností studie, kontaktujte prosím register@clinicaltrials.gov. Jakmile bude změna implementována na clinicaltrials.gov, bude automaticky aktualizována i na našem webu .