- ICH GCP
- Registr klinických studií v USA
- Klinická studie NCT07793266
ICG Fluorescence in Knee Arthroscopy Study
Intraoperative Evaluation of Blood Flow for Knee Arthroscopy Using Indocyanine Green Fluorescence Angiography
The purpose of this study is to first evaluate whether ICG fluorescence angiography can be used to evaluate blood flow of the anterior cruciate ligament (ACL), tendons, and knee structures during an arthroscopic surgery. The secondary purpose is to evaluate differences in the blood flow in patients with varying grades of ACL tears.
To determine optimal intravenous dose of SPY Agent Green and time to visualize fluorescence in tendons and structures intraoperatively during arthroscopic surgery (if primary objective is deemed yes). We hypothesize that ICG will be effective in evaluating blood flow in patients undergoing knee arthroscopy.
Přehled studie
Postavení
Intervence / Léčba
- Kombinovaný produkt: Intravenous administration of indocyanine green (SPY Agent Green) 2 mL of SPY Agent Green (5.0 mg dose)
- Kombinovaný produkt: Intravenous administration of indocyanine green (SPY Agent Green) 3 mL of SPY Agent Green (7.5 mg dose)
- Kombinovaný produkt: Intravenous administration of indocyanine green (SPY Agent Green) 4 mL of SPY Agent Green (10 mg dose)
- Kombinovaný produkt: Intravenous administration of indocyanine green (SPY Agent Green)5 mL of SPY Agent Green (12.5 mg dose)
Typ studie
Zápis (Odhadovaný)
Fáze
- Fáze 1
Kontakty a umístění
Studijní kontakt
- Jméno: Maxim A Jani, BS
- Telefonní číslo: 2488240579
- E-mail: mjani1@hfhs.org
Studijní místa
-
-
Michigan
-
Detroit, Michigan, Spojené státy, 48202
- Nábor
- Henry Ford Center for Athletic Medicine
-
Kontakt:
- Maxim A Jani, BS
- Telefonní číslo: 2488240579
- E-mail: mjani1@hfhs.org
-
-
Kritéria účasti
Kritéria způsobilosti
Věk způsobilý ke studiu
- Dítě
- Dospělý
- Starší dospělý
Přijímá zdravé dobrovolníky
Popis
Inclusion Criteria:
Patients undergoing knee arthroscopy with a HFH Orthopaedic surgeon
- Patients must be within ages of 14-89. Patient ages 14-17 will be included to capture an important sporting demographic who sustain ACL injuries which would stand to benefit from this intervention if successful.
- Have signed an approved informed consent form for the study.
- Be willing to comply with the protocol
Exclusion Criteria:
Patient is less than 14 years of age or greater than 89 years of age
- Patients who have had iodide-based radiology studies within the last seven (7) days prior to surgery
- Previous surgical repair of targeted surgical area
- Known allergy or history of adverse reaction to SPY Agent Green, ICG,
- Subjects who have participated in another investigational study within 30 days prior to surgery.
- Pregnant or lactating subjects.
- Subjects who, in the Investigator's opinion, have any medical condition that may make the subject a poor candidate for the investigational procedure, or interfere with the interpretation of study results.
Studijní plán
Jak je studie koncipována?
Detaily designu
- Primární účel: Diagnostický
- Přidělení: Nerandomizované
- Intervenční model: Sekvenční přiřazení
- Maskování: Žádné (otevřený štítek)
Zbraně a zásahy
Skupina účastníků / Arm |
Intervence / Léčba |
|---|---|
|
Experimentální: 2 mL of SPY Agent Green (5.0 mg dose)
Cohort #1: up to 10 subjects but may be modified based on fluorescence signal after 3 subjects at the discretion of PI. 2 mL of SPY Agent Green (5.0 mg dose) |
Participants undergoing knee arthroscopy will receive a single intraoperative intravenous dose of indocyanine green (ICG; SPY Agent Green) 2 mL of SPY Agent Green (5.0 mg dose).
Following administration, surgeons will use a near-infrared fluorescence-capable arthroscopy system (AIM/1788 platform) to visualize and record perfusion of intra-articular knee structures, including tendons and synovial tissues.
Fluorescence presence, time to visualization, and signal duration will be documented intraoperatively, after which the procedure will continue according to standard surgical care.
|
|
Experimentální: 3 mL of SPY Agent Green (7.5 mg dose)
Cohort #2: up to 10 subjects but may be modified based on fluorescence signal after 3 subjects at the discretion of PI. 3 mL of SPY Agent Green (7.5 mg dose) |
Participants undergoing knee arthroscopy will receive a single intraoperative intravenous dose of indocyanine green (ICG; SPY Agent Green) 3 mL of SPY Agent Green (7.5 mg dose).
Following administration, surgeons will use a near-infrared fluorescence-capable arthroscopy system (AIM/1788 platform) to visualize and record perfusion of intra-articular knee structures, including tendons and synovial tissues.
Fluorescence presence, time to visualization, and signal duration will be documented intraoperatively, after which the procedure will continue according to standard surgical care.
|
|
Experimentální: 4.0 mL of SPY Agent Green (10.0 mg dose)
Cohort #3: up to 10 subjects but may be modified based on fluorescence signal after 3 subjects at the discretion of PI. 4.0 mL of SPY Agent Green (10.0 mg dose) |
Participants undergoing knee arthroscopy will receive a single intraoperative intravenous dose of indocyanine green (ICG; SPY Agent Green) 4 mL of SPY Agent Green (10 mg dose).
Following administration, surgeons will use a near-infrared fluorescence-capable arthroscopy system (AIM/1788 platform) to visualize and record perfusion of intra-articular knee structures, including tendons and synovial tissues.
Fluorescence presence, time to visualization, and signal duration will be documented intraoperatively, after which the procedure will continue according to standard surgical care.
|
|
Experimentální: 5.0 mL of SPY Agent Green (12.5 mg dose)
Cohort #4: up to 10 subjects but may be modified based on fluorescence signal after 3 subjects at the discretion of PI. 5.0 mL of SPY Agent Green (12.5 mg dose) |
Participants undergoing knee arthroscopy will receive a single intraoperative intravenous dose of indocyanine green (ICG; SPY Agent Green) 5 mL of SPY Agent Green (12.5 mg dose).
Following administration, surgeons will use a near-infrared fluorescence-capable arthroscopy system (AIM/1788 platform) to visualize and record perfusion of intra-articular knee structures, including tendons and synovial tissues.
Fluorescence presence, time to visualization, and signal duration will be documented intraoperatively, after which the procedure will continue according to standard surgical care.
|
Co je měření studie?
Primární výstupní opatření
Měření výsledku |
Popis opatření |
Časové okno |
|---|---|---|
|
Fluorescence signal
Časové okno: From enrollment to first follow up appointment.
|
To determine if a fluorescence signal is present in knee structures during arthroscopic surgery after an intravenous administration of SPY Agent Green is given.
|
From enrollment to first follow up appointment.
|
Spolupracovníci a vyšetřovatelé
Sponzor
Spolupracovníci
Vyšetřovatelé
- Vrchní vyšetřovatel: Vasilios Moutzouros, MD, Henry Ford Health System
Termíny studijních záznamů
Hlavní termíny studia
Začátek studia (Aktuální)
Primární dokončení (Odhadovaný)
Dokončení studie (Odhadovaný)
Termíny zápisu do studia
První předloženo
První předloženo, které splnilo kritéria kontroly kvality
První zveřejněno (Aktuální)
Aktualizace studijních záznamů
Poslední zveřejněná aktualizace (Aktuální)
Odeslaná poslední aktualizace, která splnila kritéria kontroly kvality
Naposledy ověřeno
Více informací
Termíny související s touto studií
Další identifikační čísla studie
- 17358-09
Plán pro data jednotlivých účastníků (IPD)
Plánujete sdílet data jednotlivých účastníků (IPD)?
Popis plánu IPD
Informace o lécích a zařízeních, studijní dokumenty
Studuje lékový produkt regulovaný americkým FDA
Studuje produkt zařízení regulovaný americkým úřadem FDA
Tyto informace byly beze změn načteny přímo z webu clinicaltrials.gov. Máte-li jakékoli požadavky na změnu, odstranění nebo aktualizaci podrobností studie, kontaktujte prosím register@clinicaltrials.gov. Jakmile bude změna implementována na clinicaltrials.gov, bude automaticky aktualizována i na našem webu .