Tato stránka byla automaticky přeložena a přesnost překladu není zaručena. Podívejte se prosím na anglická verze pro zdrojový text.

Central Venous vs Arterial Blood Gas and CO2 Gap in Critically Ill Patients With and Without Diabetes

30. srpna 2026 aktualizováno: Mahmoud Mohamed Ali Abdelhafez, Assiut University

Correlation Between Central Venous and Arterial Blood Gas Parameters Including CO2 Gap in Diabetic and Non-Diabetic Critically Ill Patients

Frequent monitoring of acid-base status, ventilation, and tissue oxygenation is essential for managing critically ill patients in the intensive care unit (ICU). While arterial blood gas (ABG) analysis is considered the standard method for these evaluations, maintaining arterial catheters carries risks of complications, such as thrombosis, hematoma, and infection. Central venous blood gas (CVBG) analysis offers a safer alternative because central venous catheters are already routinely placed for patient care. Additionally, the venous-to-arterial carbon dioxide difference (CO2 gap) serves as an indicator of systemic blood flow and tissue perfusion.

However, patients with diabetes mellitus often present with underlying microvascular alterations, endothelial changes, and metabolic variations that might alter tissue perfusion and peripheral gas exchange. This study aims to assess the correlation and agreement between central venous and arterial blood gas parameters, as well as evaluate the diagnostic accuracy of the CO2 gap, in diabetic versus non-diabetic critically ill patients.

A total of 100 adult ICU patients (50 diabetic and 50 non-diabetic) with pre-existing central venous and arterial lines will be enrolled. Paired blood samples will be drawn simultaneously to compare blood gas values and calculate the CO2 gap without altering standard clinical treatment.

Přehled studie

Typ studie

Pozorovací

Zápis (Odhadovaný)

100

Kritéria účasti

Výzkumníci hledají lidi, kteří odpovídají určitému popisu, kterému se říká kritéria způsobilosti. Některé příklady těchto kritérií jsou celkový zdravotní stav osoby nebo předchozí léčba.

Kritéria způsobilosti

Věk způsobilý ke studiu

  • Dospělý
  • Starší dospělý

Přijímá zdravé dobrovolníky

N/A

Metoda odběru vzorků

Vzorek nepravděpodobnosti

Studijní populace

Adult critically ill patients (both diabetic and non-diabetic) admitted to the Critical Care Unit of the Internal Medicine Department at Assiut University Hospital who have standard clinical indications for indwelling central venous catheters and arterial lines.

Popis

Inclusion Criteria:

  • Adult patients aged 18 years and older
  • Critically ill patients admitted to the intensive care unit (ICU)
  • Patients with indwelling central venous catheter and arterial line placed for routine clinical management
  • Written informed consent obtained from the patient or legal next of kin

Exclusion Criteria:

  • Known severe peripheral vascular occlusive disease affecting line placement
  • Use of a pulmonary artery catheter (mixed venous blood line) instead of a standard central venous catheter positioned at the superior/inferior vena cava junction
  • Refusal of the patient or legal representative to participate in the study
  • Patients younger than 18 years of age

Studijní plán

Tato část poskytuje podrobnosti o studijním plánu, včetně toho, jak je studie navržena a co studie měří.

Jak je studie koncipována?

Detaily designu

Kohorty a intervence

Skupina / kohorta
Diabetic Critically Ill Patients
Critically ill adult patients admitted to the intensive care unit who have a confirmed diagnosis of Diabetes Mellitus. All participants undergo simultaneous paired arterial and central venous blood gas sampling to evaluate agreement and CO2 gap dynamics.
Non-Diabetic Critically Ill Patients
Critically ill adult patients admitted to the intensive care unit without a history or diagnosis of Diabetes Mellitus. All participants undergo simultaneous paired arterial and central venous blood gas sampling to evaluate agreement and CO2 gap dynamics.

Co je měření studie?

Primární výstupní opatření

Měření výsledku
Popis opatření
Časové okno
Venous-to-Arterial Carbon Dioxide Tension Difference (Delta PCO2)
Časové okno: Baseline
Delta PCO2 (CO2 gap) is calculated as central venous PCO2 minus arterial PCO2 (PvCO2 - PaCO2) measured in mmHg. Paired arterial and central venous blood gas samples are collected simultaneously and analyzed within 10 minutes.
Baseline

Spolupracovníci a vyšetřovatelé

Zde najdete lidi a organizace zapojené do této studie.

Termíny studijních záznamů

Tato data sledují průběh záznamů studie a předkládání souhrnných výsledků na ClinicalTrials.gov. Záznamy ze studií a hlášené výsledky jsou před zveřejněním na veřejné webové stránce přezkoumány Národní lékařskou knihovnou (NLM), aby se ujistily, že splňují specifické standardy kontroly kvality.

Hlavní termíny studia

Začátek studia (Odhadovaný)

1. října 2026

Primární dokončení (Odhadovaný)

1. října 2027

Dokončení studie (Odhadovaný)

1. listopadu 2027

Termíny zápisu do studia

První předloženo

30. srpna 2026

První předloženo, které splnilo kritéria kontroly kvality

30. srpna 2026

První zveřejněno (Aktuální)

2. září 2026

Aktualizace studijních záznamů

Poslední zveřejněná aktualizace (Aktuální)

2. září 2026

Odeslaná poslední aktualizace, která splnila kritéria kontroly kvality

30. srpna 2026

Naposledy ověřeno

1. srpna 2026

Více informací

Tyto informace byly beze změn načteny přímo z webu clinicaltrials.gov. Máte-li jakékoli požadavky na změnu, odstranění nebo aktualizaci podrobností studie, kontaktujte prosím register@clinicaltrials.gov. Jakmile bude změna implementována na clinicaltrials.gov, bude automaticky aktualizována i na našem webu .

Předplatit