Effect of Optic Edge Design in a Silicone Intraocular Lens on Posterior Capsule Opacification
Purpose: To compare the posterior capsule opacification (PCO) inhibiting effect of the sharp posterior optic edge design of the Clariflex silicone intraocular lens (IOL) with that of the double-round edge design of the SI40 (Phacoflex) silicone IOL over a period of 3 years.
Setting: Department of Ophthalmology, Medical University of Vienna, Vienna, Austria.
Methods: Fifty-two patients with bilateral age-related cataract (104 eyes) were included in this randomized, prospective, bilateral, patient- and examiner-masked clinical trial with intra-individual comparison. Each study patient had cataract surgery in both eyes and received an SI40 IOL (anterior and posterior round optic edges) in one eye and a Clariflex IOL with OptiEdge (round anterior and sharp posterior optic edge) in the other eye. Follow-up examinations were at one week, one month, six months, one, two, and three years. Digital retroillumination images were taken of each eye. The amount of PCO was assessed subjectively at the slit-lamp and objectively using automated image analysis software (AQUA) one, two, and three years after surgery.
Studieoversigt
Status
Betingelser
Intervention / Behandling
Undersøgelsestype
Tilmelding
Fase
- Fase 4
Kontakter og lokationer
Studiesteder
-
-
-
Vienna, Østrig, 1090
- Dept. of Ophthalmology, Medical University of Vienna
-
-
Deltagelseskriterier
Berettigelseskriterier
Aldre berettiget til at studere
Tager imod sunde frivillige
Køn, der er berettiget til at studere
Beskrivelse
Inclusion Criteria:
- bilateral, age related cataract
Exclusion Criteria:
- history of other ocular disease or intraocular surgery
- diabetes requiring medical control
Studieplan
Hvordan er undersøgelsen tilrettelagt?
Design detaljer
- Primært formål: Forebyggelse
- Tildeling: Randomiseret
- Interventionel model: Parallel tildeling
- Maskning: Dobbelt
Hvad måler undersøgelsen?
Primære resultatmål
Resultatmål |
|---|
|
amount of posterior capsule opacification (objective and subjective score 0-10)
|
Sekundære resultatmål
Resultatmål |
|---|
|
synsstyrke
|
Samarbejdspartnere og efterforskere
Sponsor
Efterforskere
- Ledende efterforsker: Rupert Menapace, MD, Medical University of Vienna
- Ledende efterforsker: Oliver Findl, MD, Medical University of Vienna
Publikationer og nyttige links
Generelle publikationer
- Buehl W, Findl O, Menapace R, Rainer G, Sacu S, Kiss B, Petternel V, Georgopoulos M. Effect of an acrylic intraocular lens with a sharp posterior optic edge on posterior capsule opacification. J Cataract Refract Surg. 2002 Jul;28(7):1105-11. doi: 10.1016/s0886-3350(02)01371-8.
- Buehl W, Findl O, Menapace R, Sacu S, Kriechbaum K, Koeppl C, Wirtitsch M. Long-term effect of optic edge design in an acrylic intraocular lens on posterior capsule opacification. J Cataract Refract Surg. 2005 May;31(5):954-61. doi: 10.1016/j.jcrs.2004.09.053.
- Buehl W, Menapace R, Sacu S, Kriechbaum K, Koeppl C, Wirtitsch M, Georgopoulos M, Findl O. Effect of a silicone intraocular lens with a sharp posterior optic edge on posterior capsule opacification. J Cataract Refract Surg. 2004 Aug;30(8):1661-7. doi: 10.1016/j.jcrs.2004.02.051.
Datoer for undersøgelser
Studer store datoer
Studiestart
Studieafslutning
Datoer for studieregistrering
Først indsendt
Først indsendt, der opfyldte QC-kriterier
Først opslået (Skøn)
Opdateringer af undersøgelsesjournaler
Sidste opdatering sendt (Skøn)
Sidste opdatering indsendt, der opfyldte kvalitetskontrolkriterier
Sidst verificeret
Mere information
Begreber relateret til denne undersøgelse
Nøgleord
Yderligere relevante MeSH-vilkår
Andre undersøgelses-id-numre
- EK2512001
Disse oplysninger blev hentet direkte fra webstedet clinicaltrials.gov uden ændringer. Hvis du har nogen anmodninger om at ændre, fjerne eller opdatere dine undersøgelsesoplysninger, bedes du kontakte register@clinicaltrials.gov. Så snart en ændring er implementeret på clinicaltrials.gov, vil denne også blive opdateret automatisk på vores hjemmeside .