- ICH GCP
- Yhdysvaltain kliinisten tutkimusten rekisteri
- Kliininen tutkimus NCT00428363
Effect of Optic Edge Design in a Silicone Intraocular Lens on Posterior Capsule Opacification
Purpose: To compare the posterior capsule opacification (PCO) inhibiting effect of the sharp posterior optic edge design of the Clariflex silicone intraocular lens (IOL) with that of the double-round edge design of the SI40 (Phacoflex) silicone IOL over a period of 3 years.
Setting: Department of Ophthalmology, Medical University of Vienna, Vienna, Austria.
Methods: Fifty-two patients with bilateral age-related cataract (104 eyes) were included in this randomized, prospective, bilateral, patient- and examiner-masked clinical trial with intra-individual comparison. Each study patient had cataract surgery in both eyes and received an SI40 IOL (anterior and posterior round optic edges) in one eye and a Clariflex IOL with OptiEdge (round anterior and sharp posterior optic edge) in the other eye. Follow-up examinations were at one week, one month, six months, one, two, and three years. Digital retroillumination images were taken of each eye. The amount of PCO was assessed subjectively at the slit-lamp and objectively using automated image analysis software (AQUA) one, two, and three years after surgery.
Tutkimuksen yleiskatsaus
Tila
Ehdot
Interventio / Hoito
Opintotyyppi
Ilmoittautuminen
Vaihe
- Vaihe 4
Yhteystiedot ja paikat
Opiskelupaikat
-
-
-
Vienna, Itävalta, 1090
- Dept. of Ophthalmology, Medical University of Vienna
-
-
Osallistumiskriteerit
Kelpoisuusvaatimukset
Opintokelpoiset iät
Hyväksyy terveitä vapaaehtoisia
Sukupuolet, jotka voivat opiskella
Kuvaus
Inclusion Criteria:
- bilateral, age related cataract
Exclusion Criteria:
- history of other ocular disease or intraocular surgery
- diabetes requiring medical control
Opintosuunnitelma
Miten tutkimus on suunniteltu?
Suunnittelun yksityiskohdat
- Ensisijainen käyttötarkoitus: Ennaltaehkäisy
- Jako: Satunnaistettu
- Inventiomalli: Rinnakkaistehtävä
- Naamiointi: Kaksinkertainen
Mitä tutkimuksessa mitataan?
Ensisijaiset tulostoimenpiteet
Tulosmittaus |
---|
amount of posterior capsule opacification (objective and subjective score 0-10)
|
Toissijaiset tulostoimenpiteet
Tulosmittaus |
---|
näöntarkkuus
|
Yhteistyökumppanit ja tutkijat
Sponsori
Tutkijat
- Päätutkija: Rupert Menapace, MD, Medical University of Vienna
- Päätutkija: Oliver Findl, MD, Medical University of Vienna
Julkaisuja ja hyödyllisiä linkkejä
Yleiset julkaisut
- Buehl W, Findl O, Menapace R, Rainer G, Sacu S, Kiss B, Petternel V, Georgopoulos M. Effect of an acrylic intraocular lens with a sharp posterior optic edge on posterior capsule opacification. J Cataract Refract Surg. 2002 Jul;28(7):1105-11. doi: 10.1016/s0886-3350(02)01371-8.
- Buehl W, Findl O, Menapace R, Sacu S, Kriechbaum K, Koeppl C, Wirtitsch M. Long-term effect of optic edge design in an acrylic intraocular lens on posterior capsule opacification. J Cataract Refract Surg. 2005 May;31(5):954-61. doi: 10.1016/j.jcrs.2004.09.053.
- Buehl W, Menapace R, Sacu S, Kriechbaum K, Koeppl C, Wirtitsch M, Georgopoulos M, Findl O. Effect of a silicone intraocular lens with a sharp posterior optic edge on posterior capsule opacification. J Cataract Refract Surg. 2004 Aug;30(8):1661-7. doi: 10.1016/j.jcrs.2004.02.051.
Opintojen ennätyspäivät
Opi tärkeimmät päivämäärät
Opiskelun aloitus
Opintojen valmistuminen
Opintoihin ilmoittautumispäivät
Ensimmäinen lähetetty
Ensimmäinen toimitettu, joka täytti QC-kriteerit
Ensimmäinen Lähetetty (Arvio)
Tutkimustietojen päivitykset
Viimeisin päivitys julkaistu (Arvio)
Viimeisin lähetetty päivitys, joka täytti QC-kriteerit
Viimeksi vahvistettu
Lisää tietoa
Tähän tutkimukseen liittyvät termit
Avainsanat
Muita asiaankuuluvia MeSH-ehtoja
Muut tutkimustunnusnumerot
- EK2512001
Nämä tiedot haettiin suoraan verkkosivustolta clinicaltrials.gov ilman muutoksia. Jos sinulla on pyyntöjä muuttaa, poistaa tai päivittää tutkimustietojasi, ota yhteyttä register@clinicaltrials.gov. Heti kun muutos on otettu käyttöön osoitteessa clinicaltrials.gov, se päivitetään automaattisesti myös verkkosivustollemme .