- ICH GCP
- Register voor klinische proeven in de VS.
- Klinische proef NCT00428363
Effect of Optic Edge Design in a Silicone Intraocular Lens on Posterior Capsule Opacification
Purpose: To compare the posterior capsule opacification (PCO) inhibiting effect of the sharp posterior optic edge design of the Clariflex silicone intraocular lens (IOL) with that of the double-round edge design of the SI40 (Phacoflex) silicone IOL over a period of 3 years.
Setting: Department of Ophthalmology, Medical University of Vienna, Vienna, Austria.
Methods: Fifty-two patients with bilateral age-related cataract (104 eyes) were included in this randomized, prospective, bilateral, patient- and examiner-masked clinical trial with intra-individual comparison. Each study patient had cataract surgery in both eyes and received an SI40 IOL (anterior and posterior round optic edges) in one eye and a Clariflex IOL with OptiEdge (round anterior and sharp posterior optic edge) in the other eye. Follow-up examinations were at one week, one month, six months, one, two, and three years. Digital retroillumination images were taken of each eye. The amount of PCO was assessed subjectively at the slit-lamp and objectively using automated image analysis software (AQUA) one, two, and three years after surgery.
Studie Overzicht
Toestand
Conditie
Interventie / Behandeling
Studietype
Inschrijving
Fase
- Fase 4
Contacten en locaties
Studie Locaties
-
-
-
Vienna, Oostenrijk, 1090
- Dept. of Ophthalmology, Medical University of Vienna
-
-
Deelname Criteria
Geschiktheidscriteria
Leeftijden die in aanmerking komen voor studie
Accepteert gezonde vrijwilligers
Geslachten die in aanmerking komen voor studie
Beschrijving
Inclusion Criteria:
- bilateral, age related cataract
Exclusion Criteria:
- history of other ocular disease or intraocular surgery
- diabetes requiring medical control
Studie plan
Hoe is de studie opgezet?
Ontwerpdetails
- Primair doel: Preventie
- Toewijzing: Gerandomiseerd
- Interventioneel model: Parallelle opdracht
- Masker: Dubbele
Wat meet het onderzoek?
Primaire uitkomstmaten
Uitkomstmaat |
|---|
|
amount of posterior capsule opacification (objective and subjective score 0-10)
|
Secundaire uitkomstmaten
Uitkomstmaat |
|---|
|
gezichtsscherpte
|
Medewerkers en onderzoekers
Sponsor
Onderzoekers
- Hoofdonderzoeker: Rupert Menapace, MD, Medical University of Vienna
- Hoofdonderzoeker: Oliver Findl, MD, Medical University of Vienna
Publicaties en nuttige links
Algemene publicaties
- Buehl W, Findl O, Menapace R, Rainer G, Sacu S, Kiss B, Petternel V, Georgopoulos M. Effect of an acrylic intraocular lens with a sharp posterior optic edge on posterior capsule opacification. J Cataract Refract Surg. 2002 Jul;28(7):1105-11. doi: 10.1016/s0886-3350(02)01371-8.
- Buehl W, Findl O, Menapace R, Sacu S, Kriechbaum K, Koeppl C, Wirtitsch M. Long-term effect of optic edge design in an acrylic intraocular lens on posterior capsule opacification. J Cataract Refract Surg. 2005 May;31(5):954-61. doi: 10.1016/j.jcrs.2004.09.053.
- Buehl W, Menapace R, Sacu S, Kriechbaum K, Koeppl C, Wirtitsch M, Georgopoulos M, Findl O. Effect of a silicone intraocular lens with a sharp posterior optic edge on posterior capsule opacification. J Cataract Refract Surg. 2004 Aug;30(8):1661-7. doi: 10.1016/j.jcrs.2004.02.051.
Studie record data
Bestudeer belangrijke data
Studie start
Studie voltooiing
Studieregistratiedata
Eerst ingediend
Eerst ingediend dat voldeed aan de QC-criteria
Eerst geplaatst (Schatting)
Updates van studierecords
Laatste update geplaatst (Schatting)
Laatste update ingediend die voldeed aan QC-criteria
Laatst geverifieerd
Meer informatie
Termen gerelateerd aan deze studie
Trefwoorden
Aanvullende relevante MeSH-voorwaarden
Andere studie-ID-nummers
- EK2512001
Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .