Effect of Optic Edge Design in a Silicone Intraocular Lens on Posterior Capsule Opacification
Purpose: To compare the posterior capsule opacification (PCO) inhibiting effect of the sharp posterior optic edge design of the Clariflex silicone intraocular lens (IOL) with that of the double-round edge design of the SI40 (Phacoflex) silicone IOL over a period of 3 years.
Setting: Department of Ophthalmology, Medical University of Vienna, Vienna, Austria.
Methods: Fifty-two patients with bilateral age-related cataract (104 eyes) were included in this randomized, prospective, bilateral, patient- and examiner-masked clinical trial with intra-individual comparison. Each study patient had cataract surgery in both eyes and received an SI40 IOL (anterior and posterior round optic edges) in one eye and a Clariflex IOL with OptiEdge (round anterior and sharp posterior optic edge) in the other eye. Follow-up examinations were at one week, one month, six months, one, two, and three years. Digital retroillumination images were taken of each eye. The amount of PCO was assessed subjectively at the slit-lamp and objectively using automated image analysis software (AQUA) one, two, and three years after surgery.
Descripción general del estudio
Estado
Condiciones
Intervención / Tratamiento
Tipo de estudio
Inscripción
Fase
- Fase 4
Contactos y Ubicaciones
Ubicaciones de estudio
-
-
-
Vienna, Austria, 1090
- Dept. of Ophthalmology, Medical University of Vienna
-
-
Criterios de participación
Criterio de elegibilidad
Edades elegibles para estudiar
Acepta Voluntarios Saludables
Géneros elegibles para el estudio
Descripción
Inclusion Criteria:
- bilateral, age related cataract
Exclusion Criteria:
- history of other ocular disease or intraocular surgery
- diabetes requiring medical control
Plan de estudios
¿Cómo está diseñado el estudio?
Detalles de diseño
- Propósito principal: Prevención
- Asignación: Aleatorizado
- Modelo Intervencionista: Asignación paralela
- Enmascaramiento: Doble
¿Qué mide el estudio?
Medidas de resultado primarias
Medida de resultado |
|---|
|
amount of posterior capsule opacification (objective and subjective score 0-10)
|
Medidas de resultado secundarias
Medida de resultado |
|---|
|
agudeza visual
|
Colaboradores e Investigadores
Patrocinador
Investigadores
- Investigador principal: Rupert Menapace, MD, Medical University of Vienna
- Investigador principal: Oliver Findl, MD, Medical University of Vienna
Publicaciones y enlaces útiles
Publicaciones Generales
- Buehl W, Findl O, Menapace R, Rainer G, Sacu S, Kiss B, Petternel V, Georgopoulos M. Effect of an acrylic intraocular lens with a sharp posterior optic edge on posterior capsule opacification. J Cataract Refract Surg. 2002 Jul;28(7):1105-11. doi: 10.1016/s0886-3350(02)01371-8.
- Buehl W, Findl O, Menapace R, Sacu S, Kriechbaum K, Koeppl C, Wirtitsch M. Long-term effect of optic edge design in an acrylic intraocular lens on posterior capsule opacification. J Cataract Refract Surg. 2005 May;31(5):954-61. doi: 10.1016/j.jcrs.2004.09.053.
- Buehl W, Menapace R, Sacu S, Kriechbaum K, Koeppl C, Wirtitsch M, Georgopoulos M, Findl O. Effect of a silicone intraocular lens with a sharp posterior optic edge on posterior capsule opacification. J Cataract Refract Surg. 2004 Aug;30(8):1661-7. doi: 10.1016/j.jcrs.2004.02.051.
Fechas de registro del estudio
Fechas importantes del estudio
Inicio del estudio
Finalización del estudio
Fechas de registro del estudio
Enviado por primera vez
Primero enviado que cumplió con los criterios de control de calidad
Publicado por primera vez (Estimar)
Actualizaciones de registros de estudio
Última actualización publicada (Estimar)
Última actualización enviada que cumplió con los criterios de control de calidad
Última verificación
Más información
Términos relacionados con este estudio
Palabras clave
Términos MeSH relevantes adicionales
Otros números de identificación del estudio
- EK2512001
Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .