Effect of Optic Edge Design in a Silicone Intraocular Lens on Posterior Capsule Opacification
Purpose: To compare the posterior capsule opacification (PCO) inhibiting effect of the sharp posterior optic edge design of the Clariflex silicone intraocular lens (IOL) with that of the double-round edge design of the SI40 (Phacoflex) silicone IOL over a period of 3 years.
Setting: Department of Ophthalmology, Medical University of Vienna, Vienna, Austria.
Methods: Fifty-two patients with bilateral age-related cataract (104 eyes) were included in this randomized, prospective, bilateral, patient- and examiner-masked clinical trial with intra-individual comparison. Each study patient had cataract surgery in both eyes and received an SI40 IOL (anterior and posterior round optic edges) in one eye and a Clariflex IOL with OptiEdge (round anterior and sharp posterior optic edge) in the other eye. Follow-up examinations were at one week, one month, six months, one, two, and three years. Digital retroillumination images were taken of each eye. The amount of PCO was assessed subjectively at the slit-lamp and objectively using automated image analysis software (AQUA) one, two, and three years after surgery.
Przegląd badań
Status
Warunki
Interwencja / Leczenie
Typ studiów
Zapisy
Faza
- Faza 4
Kontakty i lokalizacje
Lokalizacje studiów
-
-
-
Vienna, Austria, 1090
- Dept. of Ophthalmology, Medical University of Vienna
-
-
Kryteria uczestnictwa
Kryteria kwalifikacji
Wiek uprawniający do nauki
Akceptuje zdrowych ochotników
Płeć kwalifikująca się do nauki
Opis
Inclusion Criteria:
- bilateral, age related cataract
Exclusion Criteria:
- history of other ocular disease or intraocular surgery
- diabetes requiring medical control
Plan studiów
Jak projektuje się badanie?
Szczegóły projektu
- Główny cel: Zapobieganie
- Przydział: Randomizowane
- Model interwencyjny: Przydział równoległy
- Maskowanie: Podwójnie
Co mierzy badanie?
Podstawowe miary wyniku
Miara wyniku |
|---|
|
amount of posterior capsule opacification (objective and subjective score 0-10)
|
Miary wyników drugorzędnych
Miara wyniku |
|---|
|
ostrość widzenia
|
Współpracownicy i badacze
Sponsor
Śledczy
- Główny śledczy: Rupert Menapace, MD, Medical University of Vienna
- Główny śledczy: Oliver Findl, MD, Medical University of Vienna
Publikacje i pomocne linki
Publikacje ogólne
- Buehl W, Findl O, Menapace R, Rainer G, Sacu S, Kiss B, Petternel V, Georgopoulos M. Effect of an acrylic intraocular lens with a sharp posterior optic edge on posterior capsule opacification. J Cataract Refract Surg. 2002 Jul;28(7):1105-11. doi: 10.1016/s0886-3350(02)01371-8.
- Buehl W, Findl O, Menapace R, Sacu S, Kriechbaum K, Koeppl C, Wirtitsch M. Long-term effect of optic edge design in an acrylic intraocular lens on posterior capsule opacification. J Cataract Refract Surg. 2005 May;31(5):954-61. doi: 10.1016/j.jcrs.2004.09.053.
- Buehl W, Menapace R, Sacu S, Kriechbaum K, Koeppl C, Wirtitsch M, Georgopoulos M, Findl O. Effect of a silicone intraocular lens with a sharp posterior optic edge on posterior capsule opacification. J Cataract Refract Surg. 2004 Aug;30(8):1661-7. doi: 10.1016/j.jcrs.2004.02.051.
Daty zapisu na studia
Główne daty studiów
Rozpoczęcie studiów
Ukończenie studiów
Daty rejestracji na studia
Pierwszy przesłany
Pierwszy przesłany, który spełnia kryteria kontroli jakości
Pierwszy wysłany (Oszacować)
Aktualizacje rekordów badań
Ostatnia wysłana aktualizacja (Oszacować)
Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości
Ostatnia weryfikacja
Więcej informacji
Terminy związane z tym badaniem
Słowa kluczowe
Dodatkowe istotne warunki MeSH
Inne numery identyfikacyjne badania
- EK2512001
Te informacje zostały pobrane bezpośrednio ze strony internetowej clinicaltrials.gov bez żadnych zmian. Jeśli chcesz zmienić, usunąć lub zaktualizować dane swojego badania, skontaktuj się z register@clinicaltrials.gov. Gdy tylko zmiana zostanie wprowadzona na stronie clinicaltrials.gov, zostanie ona automatycznie zaktualizowana również na naszej stronie internetowej .