Product Performance of a Daily Disposable Contact Lens

13. august 2019 opdateret af: Bausch & Lomb Incorporated

A Study to Assess the Product Performance of a Daily Disposable Contact Lens

The objective of this one week, single group, bilateral, open-label study is to evaluate the product performance of the Bausch & Lomb daily disposable cosmetic tint contact lens (Test) when worn on a daily disposable basis by adapted current wearers of a marketed opaque tinted soft contact lens.

Studieoversigt

Status

Afsluttet

Betingelser

Undersøgelsestype

Interventionel

Tilmelding (Faktiske)

212

Fase

  • Ikke anvendelig

Kontakter og lokationer

Dette afsnit indeholder kontaktoplysninger for dem, der udfører undersøgelsen, og oplysninger om, hvor denne undersøgelse udføres.

Studiesteder

      • Singapore, Singapore, 556741
        • Bausch & Lomb

Deltagelseskriterier

Forskere leder efter personer, der passer til en bestemt beskrivelse, kaldet berettigelseskriterier. Nogle eksempler på disse kriterier er en persons generelle helbredstilstand eller tidligere behandlinger.

Berettigelseskriterier

Aldre berettiget til at studere

15 år til 38 år (Barn, Voksen)

Tager imod sunde frivillige

Ja

Køn, der er berettiget til at studere

Kvinde

Beskrivelse

Inclusion Criteria:

  • Subjects must be females of Chinese descent and of legal age and no older than 38. OR subjects that are females of Chinese descent and are at least 15 years of age and less than the legal age must: have a parent/legal guardian provide informed consent.
  • Subjects must have clear central corneas and be free of any anterior segment disorders.
  • Subjects must be adapted current wearers of marketed opaque tinted soft contact lenses, wear their lenses two days or more per week, and wear a lens in each eye.

Exclusion Criteria:

  • Subjects who have worn gas permeable (GP) contact lenses within the last 30 days or have worn polymethylmethacrylate (PMMA) lenses within the last three months.
  • Subjects who have any systemic disease affecting ocular health.
  • Subjects using any systemic or topical medications that will, in the Investigator's opinion, affect ocular physiology or lens performance.
  • Subjects with an active ocular disease or are using any ocular medication.
  • Subjects with any scar or neovascularization within the central 4 mm of the cornea.
  • Subjects who are aphakic or amblyopic.
  • Subjects who have had any corneal surgery (eg, refractive surgery).
  • Subjects who currently wear monovision, multifocal, or toric contact lenses.

Studieplan

Dette afsnit indeholder detaljer om studieplanen, herunder hvordan undersøgelsen er designet, og hvad undersøgelsen måler.

Hvordan er undersøgelsen tilrettelagt?

Design detaljer

  • Primært formål: Andet
  • Tildeling: N/A
  • Interventionel model: Enkelt gruppeopgave
  • Maskning: Ingen (Åben etiket)

Våben og indgreb

Deltagergruppe / Arm
Intervention / Behandling
Eksperimentel: Prism I
Bausch & Lomb daily disposable cosmetic tint contact lens
Bausch & Lomb daily disposable cosmetic tint contact lens worn on a daily disposable basis for 1 week.

Hvad måler undersøgelsen?

Primære resultatmål

Resultatmål
Foranstaltningsbeskrivelse
Tidsramme
Market Research Survey
Tidsramme: 1 week
Online subjective assessments that subjects responded to after wearing the study lenses for at least one week. Subjects were asked to rate their overall opinion as: Excellent, Very Good, Good, Fair, or Poor.
1 week

Sekundære resultatmål

Resultatmål
Foranstaltningsbeskrivelse
Tidsramme
Lens Evaluation - Centration
Tidsramme: Over all study visits through 1 week
To determine proper lens parameters the lens relationship to the eye was observed using a slit lamp. Lens centration, meaning the lens should provide full corneal coverage, was assessed during the slit lamp evaluation. Findings were reported as: Excellent, Good, Fair, or Poor.
Over all study visits through 1 week
Lens Evaluation - Movement
Tidsramme: Over all study visits through 1 week

To determine proper lens parameters the lens relationship to the eye was observed using a slit lamp. Lens movement, meaning the lens should provide discernible movement with:

  • Primary gaze blink
  • Upgaze blink
  • Upgaze lag was assessed during the slit lamp evaluation. Findings were reported as: Adequate, Excessive, Insufficient, Adherence.
Over all study visits through 1 week
Visual Acuity - Distance High Contrast logMAR (Logarithm of the Minimum Angle of Resolution) Lens Visual Acuity (VA).
Tidsramme: Over all study visits for 1 week
For determination of high contrast VA, the subject was to be seated so that the distance from the subject's eyes to the logMAR chart is 6.5 feet (2.0 meters). The chart should be at eye level for the subject. The logMAR charts have two alternative letter sequences from 28 letters (0.3 logMAR) to 62 letters (-0.3 logMAR). The visual acuity should be measured through the phoropter using the distance refractive correction with the addition of +0.50D to compensate for the reduced test distance of 6.5 feet (2.0 meters).
Over all study visits for 1 week

Samarbejdspartnere og efterforskere

Det er her, du vil finde personer og organisationer, der er involveret i denne undersøgelse.

Datoer for undersøgelser

Disse datoer sporer fremskridtene for indsendelser af undersøgelsesrekord og resumeresultater til ClinicalTrials.gov. Studieregistreringer og rapporterede resultater gennemgås af National Library of Medicine (NLM) for at sikre, at de opfylder specifikke kvalitetskontrolstandarder, før de offentliggøres på den offentlige hjemmeside.

Studer store datoer

Studiestart

1. august 2010

Primær færdiggørelse (Faktiske)

1. oktober 2010

Studieafslutning (Faktiske)

1. november 2010

Datoer for studieregistrering

Først indsendt

27. oktober 2010

Først indsendt, der opfyldte QC-kriterier

28. oktober 2010

Først opslået (Skøn)

29. oktober 2010

Opdateringer af undersøgelsesjournaler

Sidste opdatering sendt (Faktiske)

28. august 2019

Sidste opdatering indsendt, der opfyldte kvalitetskontrolkriterier

13. august 2019

Sidst verificeret

1. august 2019

Mere information

Begreber relateret til denne undersøgelse

Nøgleord

Yderligere relevante MeSH-vilkår

Andre undersøgelses-id-numre

  • 654

Disse oplysninger blev hentet direkte fra webstedet clinicaltrials.gov uden ændringer. Hvis du har nogen anmodninger om at ændre, fjerne eller opdatere dine undersøgelsesoplysninger, bedes du kontakte register@clinicaltrials.gov. Så snart en ændring er implementeret på clinicaltrials.gov, vil denne også blive opdateret automatisk på vores hjemmeside .

Kliniske forsøg med Nærsynethed

Kliniske forsøg med Daily disposable cosmetic tint lens

Abonner