Denne side blev automatisk oversat, og nøjagtigheden af ​​oversættelsen er ikke garanteret. Der henvises til engelsk version for en kildetekst.

Diagosis of Breast Carcinoma: Characterization of Breast Lesions With CLEARPEMSONIC : Feasibility Study

20. april 2015 opdateret af: Assistance Publique Hopitaux De Marseille

Breast cancer is the first cancer in women, the second etiology of death by cancer and the first cause for women between 35 and 55 years.

Diagnostic tools and large screening have been realized with positive impact in a recent review with 31% less likely to die of breast cancer over nearly 30 years compared to women who didn't get regular screening mammograms. Diagnostic tools and treatment also are improving continuously.

However, for some women, breast cancer diagnosis is difficult, in case of high density breast, breast modifications after surgery… In these cases, breast MRI is currently the best imaging tool, with high sensitivity about 90% but with a lower specificity about 60%, that lead to futile biopsies.

Recently, molecular imaging with PET-CT scan with 18FDG has permitted to widely modify cancer treatment.

However, PET-CT scan is not a good imaging tool for initial diagnostic of breast tumor because of a lack in spatial resolution about 8mm. So, researchers developed dedicated PET scan for breast, called Positron Emission Mammography. Our project is in this field of view and is named CLEARPEMSONIC.

First clinical studies with PEM showed very good performance of this imaging modality for initial evaluation of breast tumors. PEM performance is not affected by breast density, hormonal status. Spatial resolution is less than 3mm. PEM seems complementary with MRI, adding a better specificity value.

In the field of CERIMED, ClearPemSonic Project aims to evaluate an new imaging tool which combined PEM scan and ultrasonography.

Technologic evaluation was made. Now a feasibility study is the first step for clinical applications.

The main objective of this project is to confirm the feasibility of PEM scan with the ClearPEmSonic.

Secondary objectives are to compare results with other conventional imaging modalities and MRI.

The gold standard will be histology of the breast tumor.

Studieoversigt

Status

Afsluttet

Betingelser

Undersøgelsestype

Interventionel

Tilmelding (Faktiske)

10

Fase

  • Ikke anvendelig

Kontakter og lokationer

Dette afsnit indeholder kontaktoplysninger for dem, der udfører undersøgelsen, og oplysninger om, hvor denne undersøgelse udføres.

Studiesteder

      • Marseille, Frankrig, 13354
        • Assistance Publique Hopitaux de Marseille

Deltagelseskriterier

Forskere leder efter personer, der passer til en bestemt beskrivelse, kaldet berettigelseskriterier. Nogle eksempler på disse kriterier er en persons generelle helbredstilstand eller tidligere behandlinger.

Berettigelseskriterier

Aldre berettiget til at studere

18 år og ældre (Voksen, Ældre voksen)

Tager imod sunde frivillige

Ingen

Køn, der er berettiget til at studere

Kvinde

Beskrivelse

Inclusion Criteria:

  • Age > 18 years
  • Mammary Néoplasia ready(in position) (diagnosed on histological taking of type(chap) biopsy)
  • Waits whose realization of an imaging TEP-TDM in the 18FDG is required for the coverage(care) of a mammary néoplasia. The decision of realization of this TEP-TDM can be validated during a RCP.

Exclusion Criteria:

  • Other cancerous affection;
  • Pregnant Woman. Nursing mother
  • Patient presenting difficulties of follow-up (insufficient motivation, imminent transfer(transformation) in a city where the study cannot be led)
  • Patient incapable to give their written consent.
  • Patient claustrophobic or presenting a contraindication to the realization of the MRI

Studieplan

Dette afsnit indeholder detaljer om studieplanen, herunder hvordan undersøgelsen er designet, og hvad undersøgelsen måler.

Hvordan er undersøgelsen tilrettelagt?

Design detaljer

  • Tildeling: N/A
  • Interventionel model: Enkelt gruppeopgave
  • Maskning: Ingen (Åben etiket)

Våben og indgreb

Deltagergruppe / Arm
Intervention / Behandling
Eksperimentel: Breast cancer

Hvad måler undersøgelsen?

Primære resultatmål

Resultatmål
Foranstaltningsbeskrivelse
Tidsramme
MEASURE the Positron Emission Mammography (PEM)
Tidsramme: 12 months
the feasibility of PEM scan with the ClearPEmSonic
12 months

Sekundære resultatmål

Resultatmål
Foranstaltningsbeskrivelse
Tidsramme
MEASURE the other conventional imaging modalities and MRI.
Tidsramme: 12 MONTHS
to compare results with the different device
12 MONTHS

Samarbejdspartnere og efterforskere

Det er her, du vil finde personer og organisationer, der er involveret i denne undersøgelse.

Datoer for undersøgelser

Disse datoer sporer fremskridtene for indsendelser af undersøgelsesrekord og resumeresultater til ClinicalTrials.gov. Studieregistreringer og rapporterede resultater gennemgås af National Library of Medicine (NLM) for at sikre, at de opfylder specifikke kvalitetskontrolstandarder, før de offentliggøres på den offentlige hjemmeside.

Studer store datoer

Studiestart

1. marts 2012

Primær færdiggørelse (Faktiske)

1. marts 2013

Studieafslutning (Faktiske)

1. marts 2013

Datoer for studieregistrering

Først indsendt

23. marts 2012

Først indsendt, der opfyldte QC-kriterier

2. april 2012

Først opslået (Skøn)

3. april 2012

Opdateringer af undersøgelsesjournaler

Sidste opdatering sendt (Skøn)

21. april 2015

Sidste opdatering indsendt, der opfyldte kvalitetskontrolkriterier

20. april 2015

Sidst verificeret

1. april 2015

Mere information

Begreber relateret til denne undersøgelse

Andre undersøgelses-id-numre

  • 2011-A01673-38
  • 2011-40 (Anden identifikator: AP HM)

Disse oplysninger blev hentet direkte fra webstedet clinicaltrials.gov uden ændringer. Hvis du har nogen anmodninger om at ændre, fjerne eller opdatere dine undersøgelsesoplysninger, bedes du kontakte register@clinicaltrials.gov. Så snart en ændring er implementeret på clinicaltrials.gov, vil denne også blive opdateret automatisk på vores hjemmeside .

Kliniske forsøg med Brystkarcinom

Kliniske forsøg med MR

3
Abonner