Spectral Computed Tomography With Photon Counting Detector of Brain and Vessels.
Studieoversigt
Status
Intervention / Behandling
Detaljeret beskrivelse
Images of the skull/brain at the level of the inner ear/temporal bone and the level of nucleus lentiformis will be compared with the same patients routine brain done in TIA (transient ischemic attack)/stroke workup.
Images of the carotid plaque will be compared with the same patients routine CT-angiogram done in TIA/stroke workup.
Undersøgelsestype
Tilmelding (Forventet)
Kontakter og lokationer
Studiesteder
-
-
-
Stockholm, Sverige, 17176
- Rekruttering
- Karolinska Institutet, Karolinska University Hospital
-
Kontakt:
- Staffan Holmin, Professor
- Telefonnummer: +46851770000
- E-mail: staffan.holmin@ki.se
-
-
Deltagelseskriterier
Berettigelseskriterier
Aldre berettiget til at studere
Tager imod sunde frivillige
Køn, der er berettiget til at studere
Prøveudtagningsmetode
Studiebefolkning
Beskrivelse
Inclusion Criteria:
- Brain exam with CT and/or CT neck/brain vessels prior to this study. Regarding neck-vessel imaging - carotid stenosis of 30% or more. Normal kidney function.
Exclusion Criteria:
- no contraindications to iodine contrast for neck-vessel imaging with contrast.
Studieplan
Hvordan er undersøgelsen tilrettelagt?
Design detaljer
Hvad måler undersøgelsen?
Primære resultatmål
Resultatmål |
Foranstaltningsbeskrivelse |
Tidsramme |
|---|---|---|
|
Equal or better images vs classic computed tomography.
Tidsramme: During 2020
|
Are images taken with photon counting detector of brain and vessels worse, equal or better in comparison with ordinary computed tomography. Comparison of images with kernals (or algorithms) for bone and soft tissue at the level of the carotid plaque, inner ear/hindbrain and nucl lentiformis. Comparison of the ability of the spectral function - the ability to separate iodine, soft tissue and calcifications- if applicable. The comparison will be done as a grading (better, equal or worse) regarding the different kernals compared to routine CT exams from the same patient. Significance of difference between proportions with thh use of Fisher's exact test or Pearson's χ2 as appropriate. Evaluation with Cohen´s kappa with 95% CI to assess the level of inter-reader agreement |
During 2020
|
Sekundære resultatmål
Resultatmål |
Foranstaltningsbeskrivelse |
Tidsramme |
|---|---|---|
|
Diagnostic information in comparison with MRI
Tidsramme: During 2020
|
If MRI are performed of the patients brain and/or vessels - a comparison how the diagnostic information is/are relative images from MRI
|
During 2020
|
Samarbejdspartnere og efterforskere
Sponsor
Datoer for undersøgelser
Studer store datoer
Studiestart (Faktiske)
Primær færdiggørelse (Forventet)
Studieafslutning (Forventet)
Datoer for studieregistrering
Først indsendt
Først indsendt, der opfyldte QC-kriterier
Først opslået (Faktiske)
Opdateringer af undersøgelsesjournaler
Sidste opdatering sendt (Faktiske)
Sidste opdatering indsendt, der opfyldte kvalitetskontrolkriterier
Sidst verificeret
Mere information
Begreber relateret til denne undersøgelse
Andre undersøgelses-id-numre
- KI-KTH-20180111
Plan for individuelle deltagerdata (IPD)
Planlægger du at dele individuelle deltagerdata (IPD)?
IPD-planbeskrivelse
Lægemiddel- og udstyrsoplysninger, undersøgelsesdokumenter
Studerer et amerikansk FDA-reguleret lægemiddelprodukt
Studerer et amerikansk FDA-reguleret enhedsprodukt
Disse oplysninger blev hentet direkte fra webstedet clinicaltrials.gov uden ændringer. Hvis du har nogen anmodninger om at ændre, fjerne eller opdatere dine undersøgelsesoplysninger, bedes du kontakte register@clinicaltrials.gov. Så snart en ændring er implementeret på clinicaltrials.gov, vil denne også blive opdateret automatisk på vores hjemmeside .