Feasibility and Performance Evaluation for INVSENSOR00024

4. Februar 2020 aktualisiert von: Masimo Corporation

Feasibility and Performance Evaluation of INVSENSOR00024

This is a prospective, non-randomized, single arm study design to evaluate SpO2 performance of the RD SET Neo investigational pulse oximeter sensors in the neonatal population using convenience sampling in a clinical environment. The initial subjects under Protocol Version 1 were enrolled as part of a feasibility study to verify the design changes to the sensor are correct. The study protocol was amended with Protocol Version 2 to enroll a group of subjects that will be used to evaluate clinical performance for submission to regulatory agencies.

Studienübersicht

Status

Abgeschlossen

Intervention / Behandlung

Studientyp

Interventionell

Einschreibung (Tatsächlich)

28

Phase

  • Unzutreffend

Kontakte und Standorte

Dieser Abschnitt enthält die Kontaktdaten derjenigen, die die Studie durchführen, und Informationen darüber, wo diese Studie durchgeführt wird.

Studienorte

    • California
      • Stanford, California, Vereinigte Staaten, 94305
        • Stanford University Medical Center

Teilnahmekriterien

Forscher suchen nach Personen, die einer bestimmten Beschreibung entsprechen, die als Auswahlkriterien bezeichnet werden. Einige Beispiele für diese Kriterien sind der allgemeine Gesundheitszustand einer Person oder frühere Behandlungen.

Zulassungskriterien

Studienberechtigtes Alter

Nicht älter als 1 Monat (Kind)

Akzeptiert gesunde Freiwillige

Ja

Studienberechtigte Geschlechter

Alle

Beschreibung

Inclusion Criteria:

  • Less than or equal to 1 month of age
  • Weight <3kg
  • Subjects admitted with standard of care (SOC) arterial blood sampling line already in place

Exclusion Criteria:

  • Subjects with underdeveloped skin
  • Subjects with abnormalities at the planned application sites that would interfere with system measurements
  • Subjects with known allergic reactions to foam/rubber products and adhesive tape
  • Deformities of limbs, absence of feet, sever edema, and other at the discretion of the Principal Investigator

Studienplan

Dieser Abschnitt enthält Einzelheiten zum Studienplan, einschließlich des Studiendesigns und der Messung der Studieninhalte.

Wie ist die Studie aufgebaut?

Designdetails

  • Hauptzweck: Sonstiges
  • Zuteilung: N / A
  • Interventionsmodell: Einzelgruppenzuweisung
  • Maskierung: Keine (Offenes Etikett)

Waffen und Interventionen

Teilnehmergruppe / Arm
Intervention / Behandlung
Experimental: RD SET Neo SpO2
All subjects enrolled in the study will receive the investigational sensor (RD SET Neo SpO2) for evaluation of SpO2.
All subjects are enrolled in the experimental group and receive the RD SET Neo SpO2 sensor.

Was misst die Studie?

Primäre Ergebnismessungen

Ergebnis Maßnahme
Maßnahmenbeschreibung
Zeitfenster
Accuracy of Oxygen Saturation (SpO2) Measurement by RMS Calculation
Zeitfenster: up to 8 hours
Accuracy will be determined by comparing the noninvasive blood oxygen saturation measurement of the pulse oximeter to that obtained from a blood sample and calculating the root mean square (RMS) error value. In order to obtain the RMS value, the blood oxygen saturation measurement form a laboratory pulse Co-Oximeter is subtracted from the pulse oximeter oxygen saturation measurement for each sample, the average of this difference is computed as the bias. The standard deviation of the differences is computed as the precision. The square root of the sum of the squares of bias and precision is computed as the RMS Error value.
up to 8 hours

Mitarbeiter und Ermittler

Hier finden Sie Personen und Organisationen, die an dieser Studie beteiligt sind.

Studienaufzeichnungsdaten

Diese Daten verfolgen den Fortschritt der Übermittlung von Studienaufzeichnungen und zusammenfassenden Ergebnissen an ClinicalTrials.gov. Studienaufzeichnungen und gemeldete Ergebnisse werden von der National Library of Medicine (NLM) überprüft, um sicherzustellen, dass sie bestimmten Qualitätskontrollstandards entsprechen, bevor sie auf der öffentlichen Website veröffentlicht werden.

Haupttermine studieren

Studienbeginn (Tatsächlich)

25. Juni 2018

Primärer Abschluss (Tatsächlich)

8. November 2019

Studienabschluss (Tatsächlich)

8. November 2019

Studienanmeldedaten

Zuerst eingereicht

15. Juni 2018

Zuerst eingereicht, das die QC-Kriterien erfüllt hat

15. Juni 2018

Zuerst gepostet (Tatsächlich)

26. Juni 2018

Studienaufzeichnungsaktualisierungen

Letztes Update gepostet (Tatsächlich)

20. Februar 2020

Letztes eingereichtes Update, das die QC-Kriterien erfüllt

4. Februar 2020

Zuletzt verifiziert

1. Februar 2020

Mehr Informationen

Begriffe im Zusammenhang mit dieser Studie

Andere Studien-ID-Nummern

  • HAMM0002

Arzneimittel- und Geräteinformationen, Studienunterlagen

Studiert ein von der US-amerikanischen FDA reguliertes Arzneimittelprodukt

Nein

Studiert ein von der US-amerikanischen FDA reguliertes Geräteprodukt

Ja

Produkt, das in den USA hergestellt und aus den USA exportiert wird

Nein

Diese Informationen wurden ohne Änderungen direkt von der Website clinicaltrials.gov abgerufen. Wenn Sie Ihre Studiendaten ändern, entfernen oder aktualisieren möchten, wenden Sie sich bitte an register@clinicaltrials.gov. Sobald eine Änderung auf clinicaltrials.gov implementiert wird, wird diese automatisch auch auf unserer Website aktualisiert .