- Ensayo clínico NCT01109355
Positive and Expiratory Pressure and Hemorrhagic Stroke
22 de abril de 2010 actualizado por: Universidade Federal de Pernambuco
Effect of Positive End Expiratory Pressure on Cerebral Perfusion Pressure in Adult Patients With Hemorrhagic Stroke
Intrathoracic positive pressure may lead to a change hemodynamics, with repercussions for the intracranial compartment, thereby altering intracranial pressure (ICP) and cerebral perfusion pressure (CPP).
This effect may become more intense when using high positive end expiratory pressure (PEEP) values.
The aim of the present study was to measure the impact of different PEEP values on ICP, CPP and mean arterial pressure (MAP).
MAP, whereas high PEEP values increase ICP, although without clinical relevance.
Descripción general del estudio
Estado
Terminado
Condiciones
Intervención / Tratamiento
Descripción detallada
This study is a prospective clinical trial, developed in the neurological intensive care unit approved by the ethics committee and research in humans.
The charge of each patient had information about the study through the completion of informed consent and signed him when he agreed.
Were the following inclusion criteria: adult patients with acute CVA and presence of ventricular drainage catheter for invasive monitoring of ICP and without intracranial hypertension.
Were adopted as exclusion criteria: increased intracranial pressure, hemodynamic instability as a criterion of loss was used to expressions of interest in charge to leave.
All patients completed the study.
All patients were from the surgical implantation of the ventricular catheter, arriving to the ICU intubated orally and manually ventilated with an Ambu bag. Were subjected to routine procedures: adjusting the mechanical ventilator (Inter5, Intermed, BR) during assisted controlled cycled pressure and facility to monitor vital signs. After thirty minutes of stable ICU patient in a supine position with head elevated 30 °, the protocol was initiated to assess the impact of PEEP on ICP. To perform the evaluation of lung mechanics ventilatory mode was changed to control volume with the following parameters: tidal volume (Vt) = 8ml/kg weight, peak flow (PF) = 6 x minute volume, fraction of inspired O2 (FiO2) = 40%, respiratory rate (RR) = 16 bpm, sensitivity = 1 cmH2O. The following variables were monitored: PIC, Blood Pressure (BP), heart rate (HR), peak pressure in the airways (pp.) and plateau pressure of the respiratory system (Ppl.), these values were monitored with PEEP = 5 cmH2O.
During the assessment protocol was changed to pressure control ventilation mode with the following values of ventilatory parameters: Pp = 30 cm H2O, inspiratory time = 1s; FiO2 = 40%, RR = 16 bpm; Sensitivity = 1 cmH2O. PEEP employed ranged from 0 to 14 cmH2O. To eliminate a possible physiological accommodation by the progressive increase of PEEP, the range of values was determined by drawing a sealed envelope for each patient, ranging from 2 to 2 cmH2O. At each value of PEEP the patient was ventilated for a period of five minutes to carry out monitoring of ICP, BP, HR, PPC and peripheral oxygen saturation (SpO2). The ICP monitoring catheter was kept closed for drainage and open for monitoring, since the arrival of the surgical block, was only open for drainage if there was an increase in ICP above 20 mmHg.
The monitoring was carried out using the multiparameter monitor (Siemens 7000). For ICP monitoring the ventricular catheter was connected to a pressure transducer and this monitor.
After the parameters evaluated with seven different PEEP values, the ventilatory mode was changed again to control volume again to evaluate pulmonary mechanics with the same initial parameters.
All patients were from the surgical implantation of the ventricular catheter, arriving to the ICU intubated orally and manually ventilated with an Ambu bag. Were subjected to routine procedures: adjusting the mechanical ventilator (Inter5, Intermed, BR) during assisted controlled cycled pressure and facility to monitor vital signs. After thirty minutes of stable ICU patient in a supine position with head elevated 30 °, the protocol was initiated to assess the impact of PEEP on ICP. To perform the evaluation of lung mechanics ventilatory mode was changed to control volume with the following parameters: tidal volume (Vt) = 8ml/kg weight, peak flow (PF) = 6 x minute volume, fraction of inspired O2 (FiO2) = 40%, respiratory rate (RR) = 16 bpm, sensitivity = 1 cmH2O. The following variables were monitored: PIC, Blood Pressure (BP), heart rate (HR), peak pressure in the airways (pp.) and plateau pressure of the respiratory system (Ppl.), these values were monitored with PEEP = 5 cmH2O.
During the assessment protocol was changed to pressure control ventilation mode with the following values of ventilatory parameters: Pp = 30 cm H2O, inspiratory time = 1s; FiO2 = 40%, RR = 16 bpm; Sensitivity = 1 cmH2O. PEEP employed ranged from 0 to 14 cmH2O. To eliminate a possible physiological accommodation by the progressive increase of PEEP, the range of values was determined by drawing a sealed envelope for each patient, ranging from 2 to 2 cmH2O. At each value of PEEP the patient was ventilated for a period of five minutes to carry out monitoring of ICP, BP, HR, PPC and peripheral oxygen saturation (SpO2). The ICP monitoring catheter was kept closed for drainage and open for monitoring, since the arrival of the surgical block, was only open for drainage if there was an increase in ICP above 20 mmHg.
The monitoring was carried out using the multiparameter monitor (Siemens 7000). For ICP monitoring the ventricular catheter was connected to a pressure transducer and this monitor.
After the parameters evaluated with seven different PEEP values, the ventilatory mode was changed again to control volume again to evaluate pulmonary mechanics with the same initial parameters.
Tipo de estudio
Intervencionista
Inscripción (Actual)
25
Fase
- No aplica
Contactos y Ubicaciones
Esta sección proporciona los datos de contacto de quienes realizan el estudio e información sobre dónde se lleva a cabo este estudio.
Ubicaciones de estudio
-
-
Pernambuco
-
Recife, Pernambuco, Brasil
- Hospital Português
-
-
Criterios de participación
Los investigadores buscan personas que se ajusten a una determinada descripción, denominada criterio de elegibilidad. Algunos ejemplos de estos criterios son el estado de salud general de una persona o tratamientos previos.
Criterio de elegibilidad
Edades elegibles para estudiar
42 años a 86 años (Adulto, Adulto Mayor)
Acepta Voluntarios Saludables
No
Géneros elegibles para el estudio
Todos
Descripción
Inclusion Criteria:
- adult patients with acute CVA
- presence of ventricular drainage catheter for invasive monitoring of ICP
- without intracranial hypertension.
Exclusion Criteria:
- intracranial hypertension
- hemodynamic instability.
Plan de estudios
Esta sección proporciona detalles del plan de estudio, incluido cómo está diseñado el estudio y qué mide el estudio.
¿Cómo está diseñado el estudio?
Detalles de diseño
- Propósito principal: Tratamiento
- Asignación: Aleatorizado
- Modelo Intervencionista: Asignación cruzada
- Enmascaramiento: Doble
¿Qué mide el estudio?
Medidas de resultado primarias
Medida de resultado |
Medida Descripción |
|---|---|
|
Measurement of intracranial pressure
|
The ICP monitoring catheter was kept closed for drainage and open for monitoring, since the arrival of the surgical block, was only open for drainage if there was an increase in ICP above 20 mmHg.
|
Medidas de resultado secundarias
Medida de resultado |
Medida Descripción |
|---|---|
|
Effect of different values of PEEP on lung mechanics
|
- Lung compliance:During the assessment protocol was changed to pressure control ventilation mode with the following values of ventilatory parameters: Pp = 30 cm H2O, inspiratory time = 1s; FiO2 = 40%, RR = 16 bpm; Sensitivity = 1 cmH2O.
PEEP employed ranged from 0 to 14 cmH2O.
|
|
Effect of different PEEP levels on aspects hemodynamic
|
At each value of PEEP the patient was ventilated for a period of five minutes to carry out monitoring of heart rate and cerebral perfusion pressure(CPP).
|
Colaboradores e Investigadores
Aquí es donde encontrará personas y organizaciones involucradas en este estudio.
Patrocinador
Investigadores
- Silla de estudio: Roberto Campelo, Universidade Federal de Pernambuco
Publicaciones y enlaces útiles
La persona responsable de ingresar información sobre el estudio proporciona voluntariamente estas publicaciones. Estos pueden ser sobre cualquier cosa relacionada con el estudio.
Publicaciones Generales
- Pillai S, Praharaj SS, Rao GS, Kolluri VR. Cerebral perfusion pressure management of severe diffuse head injury: effect on brain compliance and intracranial pressure. Neurol India. 2004 Mar;52(1):67-71.
- Mayer SA, Copeland D, Bernardini GL, Boden-Albala B, Lennihan L, Kossoff S, Sacco RL. Cost and outcome of mechanical ventilation for life-threatening stroke. Stroke. 2000 Oct;31(10):2346-53. doi: 10.1161/01.str.31.10.2346.
Fechas de registro del estudio
Estas fechas rastrean el progreso del registro del estudio y los envíos de resultados resumidos a ClinicalTrials.gov. Los registros del estudio y los resultados informados son revisados por la Biblioteca Nacional de Medicina (NLM) para asegurarse de que cumplan con los estándares de control de calidad específicos antes de publicarlos en el sitio web público.
Fechas importantes del estudio
Inicio del estudio
1 de enero de 2008
Finalización primaria (Actual)
1 de julio de 2008
Finalización del estudio (Actual)
1 de agosto de 2008
Fechas de registro del estudio
Enviado por primera vez
19 de abril de 2010
Primero enviado que cumplió con los criterios de control de calidad
22 de abril de 2010
Publicado por primera vez (Estimar)
23 de abril de 2010
Actualizaciones de registros de estudio
Última actualización publicada (Estimar)
23 de abril de 2010
Última actualización enviada que cumplió con los criterios de control de calidad
22 de abril de 2010
Última verificación
1 de diciembre de 2009
Más información
Términos relacionados con este estudio
Términos MeSH relevantes adicionales
Otros números de identificación del estudio
- Berg 01
Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .