- ICH GCP
- Registro de ensayos clínicos de EE. UU.
- Ensayo clínico NCT01442857
The Axillary Region in a High Resolution MRI
The Axillary Region in a High Resolution MRI. Imaging Before and After Brachial Plexus Block
The axillary region is regularly used for brachial plexus block. The technique may be guided by nerve stimulation, ultrasound or a combination of nerve stimulation and ultrasound. Magnetic resonance imaging (MRI) has been beneficial in presenting anatomy of interest for regional anesthesia and in demonstrating spread of local anesthetic (LA). An axillary MRI-study at our department supported the suggestion of multiple rather than a single injection technique. Using a 0.5 Tesla open MR scanner in that study, the investigators were not able to distinguish terminal nerves from equally sized vessels. Therefore the investigators could not definitely answer whether the LA reached the pertinent nerves. The investigators have recently performed an axillary block study with a 3.0 Tesla scanner. Now the terminal nerves were identified and for each patient the investigators could observe if the LA reached the nerves.
The aim of this study was to demonstrate the anatomy of the brachial plexus in the axillary region at different levels. The investigators present the best pictures of the nerves with and without LA injected. The images are demonstrated in the axial and coronal plane.
Descripción general del estudio
Estado
Condiciones
Intervención / Tratamiento
Descripción detallada
For upper limb surgery, the brachial plexus can be blocked at the interscalene, supraclavicular, infraclavicular and axillary level as an alternative to general anesthesia. The axillary block requires more deposits to achieve a complete block. MRI investigations are of interest to better understand the block specific distribution of LA. With the new MRI Achieva 3.0T X-series (Philips Electronics, Eindhoven the Netherlands), with resolutions beyond 100μm using 2k imaging, we expected new information also compared with the earlier axillary MRI publication from our department. In that former study we used a single deposit technique in an open 0.5 Tesla scanner. We could not in that study recognize the terminal nerves or determine if the LA reached the axillary plexus.
MRI publications of the brachial plexus mostly study the shoulder region and few are describing the axillary region. We did not find any article describing the axillary brachial plexus using a 3.0 Tesla high resolution MRI.
Ultrasound visualizes the plexus nerves in the axilla and demonstrates dynamically the spread of LA. This usually occurs in 2-dimensional images where the initially observed LA fades after some minutes. MRI provides more easy 3 - dimensional images also in oblique planes compared with ultrasound.
This study was done in order to demonstrate the relevant anatomy in the volunteers and the spread of LA in patients. We also present the used protocols and MRI - stacks after having optimized the configuration of the 3.0 MRI scanner.
Tipo de estudio
Inscripción (Actual)
Fase
- Fase 2
Contactos y Ubicaciones
Ubicaciones de estudio
-
-
-
Oslo, Noruega
- The Intervention Centre, Rikshospitalet, Oslo University Hospital
-
-
Criterios de participación
Criterio de elegibilidad
Edades elegibles para estudiar
Acepta Voluntarios Saludables
Géneros elegibles para el estudio
Descripción
Inclusion Criteria:
- ASA 1 - 2.
- Anatomic volunteers or patients scheduled for hand surgery
Exclusion Criteria:
- Nerulogic disease or sequela
Plan de estudios
¿Cómo está diseñado el estudio?
Detalles de diseño
- Propósito principal: Ciencia básica
- Asignación: No aleatorizado
- Modelo Intervencionista: Asignación paralela
- Enmascaramiento: Ninguno (etiqueta abierta)
Armas e Intervenciones
Grupo de participantes/brazo |
Intervención / Tratamiento |
|---|---|
|
Experimental: Block technique
Active Comparator: Arm 1: catheter injection 40 ml of LA through the catheter Active Comparator: Arm 2: catheter and transarterial injection 20 + 10 ml transarterial block and 10 ml through the catheter |
High resolution MRI of the brachial plexus
|
¿Qué mide el estudio?
Medidas de resultado primarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
|---|---|---|
|
Pattern of local anaesthetic spread in axillary plexus block patients compared to MR images from volunteers without local anaesthesia injected.
Periodo de tiempo: 3 years
|
The optimized configuration of the 3.0 Tesla MRI scanner demonstrated detailed images from the volunteers and the patients. The image difference between the two groups was visualized and described. The investigators examined 9 volunteers and 9 patients. The volunteers were tested with different protocols in the 3.0 Tesla MRI providing anatomic pictures. The patients had two different brachial plexus blocks. Subsequently they were scanned with MRI and finally tested clinically for block efficacy before operation. |
3 years
|
Colaboradores e Investigadores
Patrocinador
Colaboradores
Investigadores
- Director de estudio: Øivind ØK Klaastad, PhD, MD, Oslo University Hospital
Publicaciones y enlaces útiles
Enlaces Útiles
Fechas de registro del estudio
Fechas importantes del estudio
Inicio del estudio
Finalización primaria (Actual)
Finalización del estudio (Actual)
Fechas de registro del estudio
Enviado por primera vez
Primero enviado que cumplió con los criterios de control de calidad
Publicado por primera vez (Estimar)
Actualizaciones de registros de estudio
Última actualización publicada (Estimar)
Última actualización enviada que cumplió con los criterios de control de calidad
Última verificación
Más información
Términos relacionados con este estudio
Palabras clave
Otros números de identificación del estudio
- S-04115A
Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .