- ICH GCP
- Registro de ensayos clínicos de EE. UU.
- Ensayo clínico NCT05120258
Can Subclavian / Infraclavicular Axillary Vein Collapsibility Index Predict Post-Spinal Hypotension in Caesarean Section Operations? (Cesarean)
Subclavian / Infraclavicular Axillary Vein Collapsibility Index in Pregnant Patients
Postspinal hypotension (PSH) is a common side effect with an incidence of 15.3% to 33%, which may result in organ hypoperfusion and ischemic events (1,2). In pregnant patients, this incidence may increase to 70% and severe PSH may increase the risk of maternal and fetal complications (3). Therefore, it is important for anesthesiologists to estimate the incidence of PSH in cesarean sections and to identify possible mechanisms (4).
One of the important factors affecting the susceptibility of patients to intraoperative hypotension is the preoperative intravascular volume status. Recently, ultrasonography of the central veins has been used frequently by anesthesiologists in the preoperative period in order to evaluate the intravascular volume status (5). Salama and Elkashlan stated that the collapsibility index of the inferior vena cava is a new predictive value for PSH (6). Choi et al. showed that the subclavian vein or infraclavicular axillary vein collapsibility index is an important predictive value for hypotension after induction of general anesthesia (7).
In this study, we wanted to investigate whether the subclavian vein or infraclavicular axillary vein collapsibility index can be used as a predictive value for PSH in cesarean section.
Descripción general del estudio
Estado
Condiciones
Tipo de estudio
Inscripción (Anticipado)
Contactos y Ubicaciones
Estudio Contacto
- Nombre: Emine ASLANLAR, assis. prof.
- Número de teléfono: 05556219830
- Correo electrónico: draslanlar@gmail.com
Copia de seguridad de contactos de estudio
- Nombre: Mehmet SARGIN, assoc. prof.
- Número de teléfono: 05322662766
- Correo electrónico: mehmet21sargin@yahoo.com
Criterios de participación
Criterio de elegibilidad
Edades elegibles para estudiar
Acepta Voluntarios Saludables
Géneros elegibles para el estudio
Método de muestreo
Población de estudio
Descripción
Inclusion Criteria:
- Spinal anesthesia
- ceserean operation
- American Society of Anesthesiologists' (ASA) physical status I-II
Exclusion Criteria:
- Patients who underwent cesarean section in emergency conditions
- Patients who underwent cesarean section under general anesthesia
- American Society of Anesthesiologists' (ASA) physical status III-IV
Plan de estudios
¿Cómo está diseñado el estudio?
Detalles de diseño
¿Qué mide el estudio?
Medidas de resultado primarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
|---|---|---|
|
Predictive value of Subclavian / Infraclavicular Axillary Vein Collapsibility Index for detecting Postspinal hypotension
Periodo de tiempo: 45 min
|
Postspinal hypotension (PSH) is a common side effect with an incidence of 15.3 to 33% that may result in organ hypoperfusion and ischaemic events.
This incidence is higher in pregnant women with a rate of 70%.
Measurement of the IVC diameter and its collapsibility index before spinal anaesthesia has been shown to be a good predictive value of the occurrence of PSH.
A previous study showed an acceptable correlation between the collapsibility of SCV (SCV-CI) and collapsibility of IVC (IVC-CI) in surgical and intensive care patients.
In this study, we measured the preoperative collapsibility index of the SCV or the infraclavicular axillary vein during respiratory variation, and then examined whether these parameters could predict hypotension after spinal anaesthesia in patients undergoing ceserean
|
45 min
|
Colaboradores e Investigadores
Patrocinador
Investigadores
- Investigador principal: Emine ASLANLAR, assis. prof., selcuk univercity medical faculty
Fechas de registro del estudio
Fechas importantes del estudio
Inicio del estudio (Anticipado)
Finalización primaria (Anticipado)
Finalización del estudio (Anticipado)
Fechas de registro del estudio
Enviado por primera vez
Primero enviado que cumplió con los criterios de control de calidad
Publicado por primera vez (Actual)
Actualizaciones de registros de estudio
Última actualización publicada (Actual)
Última actualización enviada que cumplió con los criterios de control de calidad
Última verificación
Más información
Términos relacionados con este estudio
Palabras clave
Términos MeSH relevantes adicionales
Otros números de identificación del estudio
- SCV
Información sobre medicamentos y dispositivos, documentos del estudio
Estudia un producto farmacéutico regulado por la FDA de EE. UU.
Estudia un producto de dispositivo regulado por la FDA de EE. UU.
Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .