- ICH GCP
- Yhdysvaltain kliinisten tutkimusten rekisteri
- Kliininen tutkimus NCT02415998
Transesophageal Echocardiography (TEE) to Guide and Confirm Epidural Catheters in Pediatric Patients
Tutkimuksen yleiskatsaus
Yksityiskohtainen kuvaus
The aim of this study is to assess whether transesophageal echocardiography (TEE) can be used to successfully guide an epidural catheter to a targeted thoracic level in pediatric patients. The catheter will be placed in the epidural space under real-time TEE imaging and assistance by a trained TEE operator.
The primary outcome is to determine the success rate achieved using TEE guidance to thread an epidural catheter to a targeted thoracic spinal level. Post-operative radiograph will be used to confirm catheter position.
The secondary outcomes include analysis of catheter tip position within the epidural space as anterior, lateral or inferior to the spinal cord. Further, efficacy of the catheter will be determined using the following criteria from previous studies: Hemodynamic response at skin incision analyzed by heart rate and systemic blood pressure changes using the no change in HR or BP or changes < 20% from baseline were considered "sufficient block" to surgical stimulation, while HR or BP changes > 20% from baseline were considered "not sufficient block" to surgical stimulation.
Opintotyyppi
Ilmoittautuminen (Todellinen)
Yhteystiedot ja paikat
Opiskelupaikat
-
-
Iowa
-
Iowa City, Iowa, Yhdysvallat, 52242
- University of Iowa Hosptials and Clinics
-
-
Osallistumiskriteerit
Kelpoisuusvaatimukset
Opintokelpoiset iät
Hyväksyy terveitä vapaaehtoisia
Sukupuolet, jotka voivat opiskella
Näytteenottomenetelmä
Tutkimusväestö
Kuvaus
Inclusion Criteria:
- pediatric patients scheduled to undergo cardiothoracic surgery or interventional cardiology diagnostic procedures under general anesthesia. All subjects will also be scheduled to undergo post-operative chest x-ray as a routine part of their clinical care, so no additional exposure to ionizing radiation will occur due to this study.
Exclusion Criteria:
- patients with known esophageal abnormalities, lesions or disease that would disqualify the patient for the use of TEE as standard procedure. We will further exclude any patients that are solely undergoing TEE diagnostic procedures and only include patients that are already scheduled to undergo procedures where TEE is used as part of routine surgical preparation.
Opintosuunnitelma
Miten tutkimus on suunniteltu?
Suunnittelun yksityiskohdat
Kohortit ja interventiot
Ryhmä/Kohortti |
Interventio / Hoito |
|---|---|
|
TEE
|
Epidural catheter will be placed under guidance of transesophageal echography in specific thoracic spinal segment.
|
Mitä tutkimuksessa mitataan?
Ensisijaiset tulostoimenpiteet
Tulosmittaus |
Toimenpiteen kuvaus |
Aikaikkuna |
|---|---|---|
|
Number of Participants With Successful Epidural Catheter Placement
Aikaikkuna: within one day
|
The success rate achieved using TEE guidance to thread an epidural catheter to within one targeted thoracic spinal level.
Post-operative radiograph will be used to confirm catheter position.
|
within one day
|
Yhteistyökumppanit ja tutkijat
Sponsori
Tutkijat
- Päätutkija: Kenichi Ueda, MD, University of Iowa
Julkaisuja ja hyödyllisiä linkkejä
Yleiset julkaisut
- Tsui BC, Berde CB. Caudal analgesia and anesthesia techniques in children. Curr Opin Anaesthesiol. 2005 Jun;18(3):283-8. doi: 10.1097/01.aco.0000169236.91185.5b.
- Willschke H, Marhofer P, Bosenberg A, Johnston S, Wanzel O, Sitzwohl C, Kettner S, Kapral S. Epidural catheter placement in children: comparing a novel approach using ultrasound guidance and a standard loss-of-resistance technique. Br J Anaesth. 2006 Aug;97(2):200-7. doi: 10.1093/bja/ael121. Epub 2006 May 23.
- Hassan SZ. Caudal anesthesia in infants. Anesth Analg. 1977 Sep-Oct;56(5):686-9. doi: 10.1213/00000539-197709000-00016.
- Valairucha S, Seefelder C, Houck CS. Thoracic epidural catheters placed by the caudal route in infants: the importance of radiographic confirmation. Paediatr Anaesth. 2002 Jun;12(5):424-8. doi: 10.1046/j.1460-9592.2002.00884.x.
- Blanco D, Llamazares J, Rincon R, Ortiz M, Vidal F. Thoracic epidural anesthesia via the lumbar approach in infants and children. Anesthesiology. 1996 Jun;84(6):1312-6. doi: 10.1097/00000542-199606000-00006.
- Baidya DK, Pawar DK, Dehran M, Gupta AK. Advancement of epidural catheter from lumbar to thoracic space in children: Comparison between 18G and 23G catheters. J Anaesthesiol Clin Pharmacol. 2012 Jan;28(1):21-7. doi: 10.4103/0970-9185.92429.
- Chawathe MS, Jones RM, Gildersleve CD, Harrison SK, Morris SJ, Eickmann C. Detection of epidural catheters with ultrasound in children. Paediatr Anaesth. 2003 Oct;13(8):681-4. doi: 10.1046/j.1460-9592.2003.01151.x.
- Tsui BC, Seal R, Koller J. Thoracic epidural catheter placement via the caudal approach in infants by using electrocardiographic guidance. Anesth Analg. 2002 Aug;95(2):326-30, table of contents. doi: 10.1097/00000539-200208000-00016.
- Tsui BC, Tarkkila P, Gupta S, Kearney R. Confirmation of caudal needle placement using nerve stimulation. Anesthesiology. 1999 Aug;91(2):374-8. doi: 10.1097/00000542-199908000-00010.
- Rapp HJ, Folger A, Grau T. Ultrasound-guided epidural catheter insertion in children. Anesth Analg. 2005 Aug;101(2):333-339. doi: 10.1213/01.ANE.0000156579.11254.D1.
- Roberts SA, Galvez I. Ultrasound assessment of caudal catheter position in infants. Paediatr Anaesth. 2005 May;15(5):429-32. doi: 10.1111/j.1460-9592.2004.01512.x.
- Owall A, Stahl L, Settergren G. Incidence of sore throat and patient complaints after intraoperative transesophageal echocardiography during cardiac surgery. J Cardiothorac Vasc Anesth. 1992 Feb;6(1):15-6. doi: 10.1016/1053-0770(91)90037-t.
Opintojen ennätyspäivät
Opi tärkeimmät päivämäärät
Opiskelun aloitus
Ensisijainen valmistuminen (Todellinen)
Opintojen valmistuminen (Todellinen)
Opintoihin ilmoittautumispäivät
Ensimmäinen lähetetty
Ensimmäinen toimitettu, joka täytti QC-kriteerit
Ensimmäinen Lähetetty (Arvio)
Tutkimustietojen päivitykset
Viimeisin päivitys julkaistu (Todellinen)
Viimeisin lähetetty päivitys, joka täytti QC-kriteerit
Viimeksi vahvistettu
Lisää tietoa
Tähän tutkimukseen liittyvät termit
Avainsanat
Muut tutkimustunnusnumerot
- 201207769
Nämä tiedot haettiin suoraan verkkosivustolta clinicaltrials.gov ilman muutoksia. Jos sinulla on pyyntöjä muuttaa, poistaa tai päivittää tutkimustietojasi, ota yhteyttä register@clinicaltrials.gov. Heti kun muutos on otettu käyttöön osoitteessa clinicaltrials.gov, se päivitetään automaattisesti myös verkkosivustollemme .