- ICH GCP
- Yhdysvaltain kliinisten tutkimusten rekisteri
- Kliininen tutkimus NCT02717481
Using US to Evaluate Aortic Aneurysm Size Based on 3D Co-registration to Previous CT Scan
Using Ultrasound to Evaluate Aortic Aneurysm Size Based on 3D Co-registration to Previous Computerized Tomography
Tutkimuksen yleiskatsaus
Yksityiskohtainen kuvaus
Selection test for assessing aortic aneurysm is CT angio, it performed after injection of contrast material and allows a complete demonstration of the blood vessels. This test exposes the patient to ionizing radiation and the injection of iodine contrast medium. Repeated tests pose a risk of developing a malignancy in the future due to the use of ionizing radiation and risk of renal impairment and allergic reactions due to the injection of contrast material. Ultrasound is another test that enables the detection and evaluation of aortic aneurysm. Patients with a known diagnosis of aortic aneurysm detected on CT are required to continuous monitoring in light of its growth over time and the risk of rupture.
Using Co-registration over the US device will enable to conduct a US directed aorta examination, which uses the information produced from the CT as a "roadmap" for detection and localization of the aneurysm. That can theoretically improve detection capabilities and characteristics of the aneurysm and outcomes of the invasive treatment.
Opintotyyppi
Ilmoittautuminen (Odotettu)
Yhteystiedot ja paikat
Opiskelupaikat
-
-
-
Haifa, Israel, 3109601
- Rambam healt care campus, Department of Medical Imaging
-
-
Osallistumiskriteerit
Kelpoisuusvaatimukset
Opintokelpoiset iät
Hyväksyy terveitä vapaaehtoisia
Sukupuolet, jotka voivat opiskella
Näytteenottomenetelmä
Tutkimusväestö
Kuvaus
Inclusion Criteria:
•Patients with abdominal aortic aneurysm diagnosis in clinical follow-up or after an invasive procedure to fix it.
Exclusion Criteria:
- Inability to perform Ultrasound
- Pace maker
- Hemodynamic instability
- Inability to cooperate in US examination
- Pregnant Women - does not undergo CT
Opintosuunnitelma
Miten tutkimus on suunniteltu?
Suunnittelun yksityiskohdat
Kohortit ja interventiot
Ryhmä/Kohortti |
Interventio / Hoito |
|---|---|
|
Patients with known aortic aneurysm
Patients with known abdominal aortic aneurysm diagnosed in clinical follow-up or after an invasive procedure to repair it. US-CT Fusion examination |
Patients will undergo an US examination using an US device with US-CT Fusion capabilities.
|
Mitä tutkimuksessa mitataan?
Ensisijaiset tulostoimenpiteet
Tulosmittaus |
Toimenpiteen kuvaus |
Aikaikkuna |
|---|---|---|
|
Exact and reliable evaluation of the aneurysm size
Aikaikkuna: two years
|
The size of the aneurysm will be evaluated by two different doctors or twice with large time frame between the studies. The difference between the measurements with the fusion technology will be compared to the difference without the fusion technology. The accuracy of the measurement will be evaluated by comparing to previous CT examination. |
two years
|
Toissijaiset tulostoimenpiteet
Tulosmittaus |
Aikaikkuna |
|---|---|
|
The size difference between systolic and diastolic aneurysm.
Aikaikkuna: two years
|
two years
|
|
Aneurysm neck size and changes following an invasive procedure to repair it (EVAR).
Aikaikkuna: two years
|
two years
|
|
Evaluation of the pressure on the aneurysmal wall.
Aikaikkuna: two years
|
two years
|
Yhteistyökumppanit ja tutkijat
Sponsori
Tutkijat
- Päätutkija: Diana Gaitini, MD, Prof., Director of Ultrasound Unit, Rambam Health Care Campus
Julkaisuja ja hyödyllisiä linkkejä
Yleiset julkaisut
- Kobeiter H, Nahum J, Becquemin JP. Zero-contrast thoracic endovascular aortic repair using image fusion. Circulation. 2011 Sep 13;124(11):e280-2. doi: 10.1161/CIRCULATIONAHA.110.014118. No abstract available. Erratum In: Circulation. 2011 Dec 6;124(23):e782.
- McNally MM, Scali ST, Feezor RJ, Neal D, Huber TS, Beck AW. Three-dimensional fusion computed tomography decreases radiation exposure, procedure time, and contrast use during fenestrated endovascular aortic repair. J Vasc Surg. 2015 Feb;61(2):309-16. doi: 10.1016/j.jvs.2014.07.097. Epub 2014 Aug 28. Erratum In: J Vasc Surg. 2015 May;61(5):1382. J Vasc Surg. 2015 Sep;62(3):839.
- Pfister K, Schierling W, Jung EM, Apfelbeck H, Hennersperger C, Kasprzak PM. Standardized 2D ultrasound versus 3D/4D ultrasound and image fusion for measurement of aortic aneurysm diameter in follow-up after EVAR. Clin Hemorheol Microcirc. 2016;62(3):249-60. doi: 10.3233/CH-152012.
Opintojen ennätyspäivät
Opi tärkeimmät päivämäärät
Opiskelun aloitus
Ensisijainen valmistuminen (Odotettu)
Opintojen valmistuminen (Odotettu)
Opintoihin ilmoittautumispäivät
Ensimmäinen lähetetty
Ensimmäinen toimitettu, joka täytti QC-kriteerit
Ensimmäinen Lähetetty (Arvio)
Tutkimustietojen päivitykset
Viimeisin päivitys julkaistu (Arvio)
Viimeisin lähetetty päivitys, joka täytti QC-kriteerit
Viimeksi vahvistettu
Lisää tietoa
Tähän tutkimukseen liittyvät termit
Muita asiaankuuluvia MeSH-ehtoja
Muut tutkimustunnusnumerot
- 0551-15 RMB CTIL
Yksittäisten osallistujien tietojen suunnitelma (IPD)
Aiotko jakaa yksittäisten osallistujien tietoja (IPD)?
IPD-suunnitelman kuvaus
Nämä tiedot haettiin suoraan verkkosivustolta clinicaltrials.gov ilman muutoksia. Jos sinulla on pyyntöjä muuttaa, poistaa tai päivittää tutkimustietojasi, ota yhteyttä register@clinicaltrials.gov. Heti kun muutos on otettu käyttöön osoitteessa clinicaltrials.gov, se päivitetään automaattisesti myös verkkosivustollemme .