Comparative Evaluation of the McGrath Videolaryngoscope and the Direct Laryngoscopy for Tracheal Intubation in the Prehospital Setting (AMAC)
In the prehospital setting, the risk of difficult intubation and life-threatening complications is increased under particular conditions due to the environment or the frequent instability of patients.
To limit this risk procedures and devices to ease and secure tracheal intubation must be developped and integrated.
As the prevalence of complications increase with the number of attempts of intubation, one strategy is to facilitate the intubation technic itself.
Direct laryngoscopy with Macintosh blades is the standard device commonly used in first place for tracheal intubation.
Other devices are available and used, mostly for difficult intubation, included videolaryngoscopy. This device has been used and studied for years now. Allowing a better view and glottic visualisation, videolaryngoscopy could increase the first-pass success rate.
Among all videolaryngoscopes, the McGrath videolaryngoscope is the most similar device to the standard Macintosh laryngoscope. It is light, compact, with a screen directly linked to the handle, easy to use and offering excellent view. Its usability and efficacy make it a device of choice for the prehospital setting and worth further clinical trials to define its place in the airway strategy.
Hypothesis: In the prehospital setting, the use of McGrath videolaryngoscope as the primary device for tracheal intubation could facilitate tracheal intubation and decrease the number of attempts of intubation and complications.
The objective of our study is to determine if the use of McGrath videolaryngoscope increase the rate of successful first-pass intubation in the prehospital setting compared to direct view Macintosh laryngoscopy.
The primary outcome is the rate of successful intubation at the first attempt. One attempt is defined as an advancement of the tube towards the glottis during a laryngoscopy ; every new try even during the same laryngoscopy is considered as a new attempt.
Successful intubation is confirmed by the visualisation of 6 waves of EtCO2.
Tutkimuksen yleiskatsaus
Tila
Ehdot
Interventio / Hoito
Opintotyyppi
Ilmoittautuminen (Odotettu)
Vaihe
- Vaihe 3
Yhteystiedot ja paikat
Opiskeluyhteys
- Nimi: Baudoin Clémence
- Puhelinnumero: +331 49 95 61 61
- Sähköposti: clemence.baudoin@aphp.fr
Tutki yhteystietojen varmuuskopiointi
- Nimi: Matthieu Resche-Rigon
- Puhelinnumero: +33142499773
- Sähköposti: matthieu.resche-rigon@u-paris.fr
Osallistumiskriteerit
Kelpoisuusvaatimukset
Opintokelpoiset iät
Hyväksyy terveitä vapaaehtoisia
Sukupuolet, jotka voivat opiskella
Kuvaus
Inclusion Criteria:
- Age more than 18
- Indication of orotracheal intubation
- Operators trained to the use of the McGrath
Exclusion Criteria:
- Pregnancy
- No insurance
- Major patient under guardianship or curatorship
Opintosuunnitelma
Miten tutkimus on suunniteltu?
Suunnittelun yksityiskohdat
- Ensisijainen käyttötarkoitus: Muut
- Jako: Satunnaistettu
- Inventiomalli: Rinnakkaistehtävä
- Naamiointi: Ei mitään (avoin tarra)
Aseet ja interventiot
Osallistujaryhmä / Arm |
Interventio / Hoito |
|---|---|
|
Muut: Videolaryngoscopy group
|
Tracheal intubation will be performed using Videolaryngoscope in first intention and will be performed using standard pre-hospital intubation procedures : preoxygenation before intubation, maintenance of oxygenation throughout procedure, standard sedation technique (using rapid sequence intubation (RSI)), correct position confirmation using a capnogram and conditioning (hemodynamic monitoring, respirator settings, securing).
If the first attempt at intubation is unsuccessful, further management will be left to the discretion of the clinician according to the procedures and algorithm of usual standard care
|
|
Muut: Direct laryngoscopy group
|
Tracheal intubation will be performed using Direct laryngoscopy with Macintosh blades in first intention.
and will be performed using standard pre-hospital intubation procedures : preoxygenation before intubation, maintenance of oxygenation throughout procedure, standard sedation technique (using rapid sequence intubation (RSI)), correct position confirmation using a capnogram and conditioning (hemodynamic monitoring, respirator settings, securing).
If the first attempt at intubation is unsuccessful, further management will be left to the discretion of the clinician according to the procedures and algorithm of usual standard care
|
Mitä tutkimuksessa mitataan?
Ensisijaiset tulostoimenpiteet
Tulosmittaus |
Toimenpiteen kuvaus |
Aikaikkuna |
|---|---|---|
|
Rate of successful intubation at the first attempt
Aikaikkuna: up to 10 minutes post inclusion
|
One attempt is defined as an advancement of the tube towards the glottis during a laryngoscopy ; every new try even during the same laryngoscopy is considered as a new attempt.Successful intubation is confirmed by the visualisation of 6 waves of EtCO2.
|
up to 10 minutes post inclusion
|
Toissijaiset tulostoimenpiteet
Tulosmittaus |
Toimenpiteen kuvaus |
Aikaikkuna |
|---|---|---|
|
Number of attempts needed for successful intubation
Aikaikkuna: up to 10 minutes post inclusion
|
up to 10 minutes post inclusion
|
|
|
Time to intubate
Aikaikkuna: up to 10 minutes post inclusion
|
Time to intubate will be defined by the time between the insertion of the device in the mouth and the visualisation of the first waves of EtCO2
|
up to 10 minutes post inclusion
|
|
Reason of failure of the first-pass success
Aikaikkuna: up to 10 minutes post inclusion
|
Reasons of failure will be defined as following :
|
up to 10 minutes post inclusion
|
|
Proportion of decision of switch in case of failure
Aikaikkuna: up to 10 minutes post inclusion
|
up to 10 minutes post inclusion
|
|
|
Proportion of difficult intubations
Aikaikkuna: up to 10 minutes post inclusion
|
Difficult intubation will be evaluated by the intubation difficulty score (score IDS or difficulty of intubation under laryngoscopy score ).
It goes from 0 to infinity.
zero indicating an easy intubation and infinity being an impossible intubation
|
up to 10 minutes post inclusion
|
|
Glottic view
Aikaikkuna: up to 10 minutes post inclusion
|
Glottic view will be evaluated with Cormack and Lehane grade and POGO score.
POGO score goes from 0 (Visualization of the language base) to 100% (total visualization of the glottis).
Cormack and Lehane grade goes from I to IV.
A higher Cormack and Lehane grade is worth : I indicate total visualization of the glottis and IV indicate Visualization of the language base
|
up to 10 minutes post inclusion
|
|
Proportion of cases who need for tools to optimize
Aikaikkuna: up to 10 minutes post inclusion
|
up to 10 minutes post inclusion
|
|
|
Proportion of cases needed crossovers to other rescue techniques
Aikaikkuna: up to 10 minutes post inclusion
|
up to 10 minutes post inclusion
|
|
|
Number of complications per and post-intubation
Aikaikkuna: up to 10 minutes post inclusion
|
up to 10 minutes post inclusion
|
|
|
Type of complications per and post-intubation
Aikaikkuna: up to 10 minutes post inclusion
|
up to 10 minutes post inclusion
|
|
|
Number of deaths
Aikaikkuna: up to 10 minutes post inclusion
|
up to 10 minutes post inclusion
|
Yhteistyökumppanit ja tutkijat
Opintojen ennätyspäivät
Opi tärkeimmät päivämäärät
Opiskelun aloitus (Odotettu)
Ensisijainen valmistuminen (Odotettu)
Opintojen valmistuminen (Odotettu)
Opintoihin ilmoittautumispäivät
Ensimmäinen lähetetty
Ensimmäinen toimitettu, joka täytti QC-kriteerit
Ensimmäinen Lähetetty (Todellinen)
Tutkimustietojen päivitykset
Viimeisin päivitys julkaistu (Todellinen)
Viimeisin lähetetty päivitys, joka täytti QC-kriteerit
Viimeksi vahvistettu
Lisää tietoa
Tähän tutkimukseen liittyvät termit
Muita asiaankuuluvia MeSH-ehtoja
Muut tutkimustunnusnumerot
- K170405J
Yksittäisten osallistujien tietojen suunnitelma (IPD)
Aiotko jakaa yksittäisten osallistujien tietoja (IPD)?
Lääke- ja laitetiedot, tutkimusasiakirjat
Tutkii yhdysvaltalaista FDA sääntelemää lääkevalmistetta
Tutkii yhdysvaltalaista FDA sääntelemää laitetuotetta
Nämä tiedot haettiin suoraan verkkosivustolta clinicaltrials.gov ilman muutoksia. Jos sinulla on pyyntöjä muuttaa, poistaa tai päivittää tutkimustietojasi, ota yhteyttä register@clinicaltrials.gov. Heti kun muutos on otettu käyttöön osoitteessa clinicaltrials.gov, se päivitetään automaattisesti myös verkkosivustollemme .