Эта страница была переведена автоматически, точность перевода не гарантируется. Пожалуйста, обратитесь к английской версии для исходного текста.

Comparative Evaluation of the McGrath Videolaryngoscope and the Direct Laryngoscopy for Tracheal Intubation in the Prehospital Setting (AMAC)

14 июня 2021 г. обновлено: Assistance Publique - Hôpitaux de Paris

In the prehospital setting, the risk of difficult intubation and life-threatening complications is increased under particular conditions due to the environment or the frequent instability of patients.

To limit this risk procedures and devices to ease and secure tracheal intubation must be developped and integrated.

As the prevalence of complications increase with the number of attempts of intubation, one strategy is to facilitate the intubation technic itself.

Direct laryngoscopy with Macintosh blades is the standard device commonly used in first place for tracheal intubation.

Other devices are available and used, mostly for difficult intubation, included videolaryngoscopy. This device has been used and studied for years now. Allowing a better view and glottic visualisation, videolaryngoscopy could increase the first-pass success rate.

Among all videolaryngoscopes, the McGrath videolaryngoscope is the most similar device to the standard Macintosh laryngoscope. It is light, compact, with a screen directly linked to the handle, easy to use and offering excellent view. Its usability and efficacy make it a device of choice for the prehospital setting and worth further clinical trials to define its place in the airway strategy.

Hypothesis: In the prehospital setting, the use of McGrath videolaryngoscope as the primary device for tracheal intubation could facilitate tracheal intubation and decrease the number of attempts of intubation and complications.

The objective of our study is to determine if the use of McGrath videolaryngoscope increase the rate of successful first-pass intubation in the prehospital setting compared to direct view Macintosh laryngoscopy.

The primary outcome is the rate of successful intubation at the first attempt. One attempt is defined as an advancement of the tube towards the glottis during a laryngoscopy ; every new try even during the same laryngoscopy is considered as a new attempt.

Successful intubation is confirmed by the visualisation of 6 waves of EtCO2.

Обзор исследования

Тип исследования

Интервенционный

Регистрация (Ожидаемый)

150

Фаза

  • Фаза 3

Контакты и местонахождение

В этом разделе приведены контактные данные лиц, проводящих исследование, и информация о том, где проводится это исследование.

Контакты исследования

  • Имя: Baudoin Clémence
  • Номер телефона: +331 49 95 61 61
  • Электронная почта: clemence.baudoin@aphp.fr

Учебное резервное копирование контактов

Критерии участия

Исследователи ищут людей, которые соответствуют определенному описанию, называемому критериям приемлемости. Некоторыми примерами этих критериев являются общее состояние здоровья человека или предшествующее лечение.

Критерии приемлемости

Возраст, подходящий для обучения

18 лет и старше (Взрослый, Пожилой взрослый)

Принимает здоровых добровольцев

Нет

Полы, имеющие право на обучение

Все

Описание

Inclusion Criteria:

  • Age more than 18
  • Indication of orotracheal intubation
  • Operators trained to the use of the McGrath

Exclusion Criteria:

  • Pregnancy
  • No insurance
  • Major patient under guardianship or curatorship

Учебный план

В этом разделе представлена ​​подробная информация о плане исследования, в том числе о том, как планируется исследование и что оно измеряет.

Как устроено исследование?

Детали дизайна

  • Основная цель: Другой
  • Распределение: Рандомизированный
  • Интервенционная модель: Параллельное назначение
  • Маскировка: Нет (открытая этикетка)

Оружие и интервенции

Группа участников / Армия
Вмешательство/лечение
Другой: Videolaryngoscopy group
Tracheal intubation will be performed using Videolaryngoscope in first intention and will be performed using standard pre-hospital intubation procedures : preoxygenation before intubation, maintenance of oxygenation throughout procedure, standard sedation technique (using rapid sequence intubation (RSI)), correct position confirmation using a capnogram and conditioning (hemodynamic monitoring, respirator settings, securing). If the first attempt at intubation is unsuccessful, further management will be left to the discretion of the clinician according to the procedures and algorithm of usual standard care
Другой: Direct laryngoscopy group
Tracheal intubation will be performed using Direct laryngoscopy with Macintosh blades in first intention. and will be performed using standard pre-hospital intubation procedures : preoxygenation before intubation, maintenance of oxygenation throughout procedure, standard sedation technique (using rapid sequence intubation (RSI)), correct position confirmation using a capnogram and conditioning (hemodynamic monitoring, respirator settings, securing). If the first attempt at intubation is unsuccessful, further management will be left to the discretion of the clinician according to the procedures and algorithm of usual standard care

Что измеряет исследование?

Первичные показатели результатов

Мера результата
Мера Описание
Временное ограничение
Rate of successful intubation at the first attempt
Временное ограничение: up to 10 minutes post inclusion
One attempt is defined as an advancement of the tube towards the glottis during a laryngoscopy ; every new try even during the same laryngoscopy is considered as a new attempt.Successful intubation is confirmed by the visualisation of 6 waves of EtCO2.
up to 10 minutes post inclusion

Вторичные показатели результатов

Мера результата
Мера Описание
Временное ограничение
Number of attempts needed for successful intubation
Временное ограничение: up to 10 minutes post inclusion
up to 10 minutes post inclusion
Time to intubate
Временное ограничение: up to 10 minutes post inclusion
Time to intubate will be defined by the time between the insertion of the device in the mouth and the visualisation of the first waves of EtCO2
up to 10 minutes post inclusion
Reason of failure of the first-pass success
Временное ограничение: up to 10 minutes post inclusion

Reasons of failure will be defined as following :

  • Bad glottic visualization
  • Difficult progression of the tube towards the glottis despite a good visualisation
  • Presence of secretions
  • Presence of foreign body
  • Presence of fogging on the McGrath
  • Device failure
  • Other
up to 10 minutes post inclusion
Proportion of decision of switch in case of failure
Временное ограничение: up to 10 minutes post inclusion
up to 10 minutes post inclusion
Proportion of difficult intubations
Временное ограничение: up to 10 minutes post inclusion
Difficult intubation will be evaluated by the intubation difficulty score (score IDS or difficulty of intubation under laryngoscopy score ). It goes from 0 to infinity. zero indicating an easy intubation and infinity being an impossible intubation
up to 10 minutes post inclusion
Glottic view
Временное ограничение: up to 10 minutes post inclusion
Glottic view will be evaluated with Cormack and Lehane grade and POGO score. POGO score goes from 0 (Visualization of the language base) to 100% (total visualization of the glottis). Cormack and Lehane grade goes from I to IV. A higher Cormack and Lehane grade is worth : I indicate total visualization of the glottis and IV indicate Visualization of the language base
up to 10 minutes post inclusion
Proportion of cases who need for tools to optimize
Временное ограничение: up to 10 minutes post inclusion
up to 10 minutes post inclusion
Proportion of cases needed crossovers to other rescue techniques
Временное ограничение: up to 10 minutes post inclusion
up to 10 minutes post inclusion
Number of complications per and post-intubation
Временное ограничение: up to 10 minutes post inclusion
up to 10 minutes post inclusion
Type of complications per and post-intubation
Временное ограничение: up to 10 minutes post inclusion
up to 10 minutes post inclusion
Number of deaths
Временное ограничение: up to 10 minutes post inclusion
up to 10 minutes post inclusion

Соавторы и исследователи

Здесь вы найдете людей и организации, участвующие в этом исследовании.

Даты записи исследования

Эти даты отслеживают ход отправки отчетов об исследованиях и сводных результатов на сайт ClinicalTrials.gov. Записи исследований и сообщаемые результаты проверяются Национальной медицинской библиотекой (NLM), чтобы убедиться, что они соответствуют определенным стандартам контроля качества, прежде чем публиковать их на общедоступном веб-сайте.

Изучение основных дат

Начало исследования (Ожидаемый)

15 июня 2021 г.

Первичное завершение (Ожидаемый)

15 декабря 2021 г.

Завершение исследования (Ожидаемый)

15 декабря 2021 г.

Даты регистрации исследования

Первый отправленный

7 июня 2021 г.

Впервые представлено, что соответствует критериям контроля качества

14 июня 2021 г.

Первый опубликованный (Действительный)

18 июня 2021 г.

Обновления учебных записей

Последнее опубликованное обновление (Действительный)

18 июня 2021 г.

Последнее отправленное обновление, отвечающее критериям контроля качества

14 июня 2021 г.

Последняя проверка

1 мая 2021 г.

Дополнительная информация

Термины, связанные с этим исследованием

Другие идентификационные номера исследования

  • K170405J

Планирование данных отдельных участников (IPD)

Планируете делиться данными об отдельных участниках (IPD)?

НЕ РЕШЕНО

Информация о лекарствах и устройствах, исследовательские документы

Изучает лекарственный продукт, регулируемый FDA США.

Нет

Изучает продукт устройства, регулируемый Управлением по санитарному надзору за качеством пищевых продуктов и медикаментов США.

Нет

Эта информация была получена непосредственно с веб-сайта clinicaltrials.gov без каких-либо изменений. Если у вас есть запросы на изменение, удаление или обновление сведений об исследовании, обращайтесь по адресу register@clinicaltrials.gov. Как только изменение будет реализовано на clinicaltrials.gov, оно будет автоматически обновлено и на нашем веб-сайте. .

Подписаться