- ICH GCP
- Registre américain des essais cliniques
- Essai clinique NCT00080587
Atherosclerosis in the Coronary and Carotid Arteries
Atherosclerosis in the Coronary and Carotid Arteries: Correlations Between Coronary IVUS, Carotid Ultrasound, and Carotid MRI
This study will compare changes in atherosclerotic plaque in the coronary arteries (vessels on the surface of the heart that supply blood to the heart) with changes in the carotid arteries (vessels in the neck that supply blood to the brain) in patients enrolled in a Pfizer-sponsored treatment trial for coronary artery disease. Atherosclerosis is a buildup of fatty deposits (plaque) in arteries that can lead to blockage of the vessel, possibly resulting in heart attack or stroke. A major question in cardiovascular disease is how closely atherosclerotic changes in the coronary arteries correlate with changes in the carotid artery that occur with treatment. substudy of a Pfizer.
Patients enrolled in the Pfizer trial comparing the effectiveness of the drug atorvastatin with a combination of atorvastatin and CETP inhibitor (a drug to increase HDL cholesterol levels) may be eligible for this substudy.
Participants undergo magnetic resonance imaging (MRI) and ultrasound of the carotid arteries to measure the thickness of the vessels. The results are then compared with the coronary artery images obtained as part of the patient's evaluation for the Pfizer trial.
MRI
MRI scans use a powerful magnet with an advanced computer system and radio waves to produce accurate, detailed pictures of organs and tissues. During the scan the patient lies on a table in a narrow cylinder containing a magnetic field, wearing earplugs to muffle loud noises that occur with electrical switching of the magnetic fields. A medicine called gadolinium contrast may be injected into a vein during part of the scan to brighten the images. The scan takes about 30 to 90 minutes. An electrocardiogram (ECG) is done during the scan to monitor the heart's electrical activity. Patients who agree to undergo another MRI test are also imaged in a scanner that uses a stronger (3 Tesla) magnet.
Ultrasound
An echocardiogram (ultrasound of the heart) uses sound waves to image the carotid arteries. A gel is applied to the area of the neck to be imaged and a small handheld ultrasound probe is held against the neck to take the pictures.
Participants return after 2 years for a second set of tests.
Aperçu de l'étude
Statut
Les conditions
Description détaillée
Type d'étude
Inscription
Contacts et emplacements
Lieux d'étude
-
-
Maryland
-
Bethesda, Maryland, États-Unis, 20892
- National Heart, Lung and Blood Institute (NHLBI)
-
-
Critères de participation
Critère d'éligibilité
Âges éligibles pour étudier
- Enfant
- Adulte
- Adulte plus âgé
Accepte les volontaires sains
Sexes éligibles pour l'étude
La description
INCLUSION CRITERIA
Patients will be a subset of patients participating in the multicenter IVUS protocol.
Willingness to travel to the NIH to participate in the NHLBI MRI/IMT study.
EXCLUSION CRITERIA
Pacemaker
Defibrillator
Brain aneurysm clips
Implanted active medical devices (neural stimulators, cochlear implants, insulin pumps, etc.)
Severe claustrophobia
Allergy to gadolinium based contrast agents (only excludes the gadolinium portion of the test)
Plan d'étude
Comment l'étude est-elle conçue ?
Collaborateurs et enquêteurs
Publications et liens utiles
Publications générales
- Corti R, Fuster V, Fayad ZA, Worthley SG, Helft G, Smith D, Weinberger J, Wentzel J, Mizsei G, Mercuri M, Badimon JJ. Lipid lowering by simvastatin induces regression of human atherosclerotic lesions: two years' follow-up by high-resolution noninvasive magnetic resonance imaging. Circulation. 2002 Dec 3;106(23):2884-7. doi: 10.1161/01.cir.0000041255.88750.f0.
- Fayad ZA. MR imaging for the noninvasive assessment of atherothrombotic plaques. Magn Reson Imaging Clin N Am. 2003 Feb;11(1):101-13. doi: 10.1016/s1064-9689(02)00023-5.
- Wasserman BA, Smith WI, Trout HH 3rd, Cannon RO 3rd, Balaban RS, Arai AE. Carotid artery atherosclerosis: in vivo morphologic characterization with gadolinium-enhanced double-oblique MR imaging initial results. Radiology. 2002 May;223(2):566-73. doi: 10.1148/radiol.2232010659.
Dates d'enregistrement des études
Dates principales de l'étude
Début de l'étude
Achèvement de l'étude
Dates d'inscription aux études
Première soumission
Première soumission répondant aux critères de contrôle qualité
Première publication (Estimation)
Mises à jour des dossiers d'étude
Dernière mise à jour publiée (Estimation)
Dernière mise à jour soumise répondant aux critères de contrôle qualité
Dernière vérification
Plus d'information
Termes liés à cette étude
Mots clés
Termes MeSH pertinents supplémentaires
Autres numéros d'identification d'étude
- 040154
- 04-H-0154
Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .