Cette page a été traduite automatiquement et l'exactitude de la traduction n'est pas garantie. Veuillez vous référer au version anglaise pour un texte source.

CRM and Fusion Beats: Effects of Progressive Fusion on Intra-left Ventricular Mechanical Function

31 août 2011 mis à jour par: Essentia Health

This study is looking at cardiac rhythm management (CRM) and fusion beats in patients who have a pacemaker or implantable cardioverter-defibrillator (ICD), to determine if there is a correlation between the time between the contraction of the upper chambers of the heart (atrium) and the lower chambers of the heart, (ventricle) and heart function.

Some studies of people with pacemakers have been done to determine if shortening the time of contraction between the atrium and ventricle could benefit the function of the left ventricle. These studies have shown that there is no benefit in heart function.There have been other studies which have shown that chronic pacing of the right ventricle, especially with the lead placed at the tip of the right ventricle, can lead to a decrease in the function of the left ventricle and congestive heart failure. In some patients long term pacing of the right ventricle has also been associated with a reduction in the ability of the left ventricle to pump blood. This is know as a reduced left ventricular ejection fraction, which can be documented by an echocardiogram.

This study proposes to evaluate the acute effects of progressive paced fusion beats on the left ventricle to answer the question whether there is an delay between the atrium and ventricle that is "too long" or "too short".

Aperçu de l'étude

Statut

Complété

Les conditions

Type d'étude

Observationnel

Inscription (Réel)

25

Contacts et emplacements

Cette section fournit les coordonnées de ceux qui mènent l'étude et des informations sur le lieu où cette étude est menée.

Lieux d'étude

    • Minnesota
      • Duluth, Minnesota, États-Unis, 55805
        • Essentia Health

Critères de participation

Les chercheurs recherchent des personnes qui correspondent à une certaine description, appelée critères d'éligibilité. Certains exemples de ces critères sont l'état de santé général d'une personne ou des traitements antérieurs.

Critère d'éligibilité

Âges éligibles pour étudier

18 ans et plus (Adulte, Adulte plus âgé)

Accepte les volontaires sains

Non

Sexes éligibles pour l'étude

Tout

Méthode d'échantillonnage

Échantillon non probabiliste

Population étudiée

Pacemaker clinic or inpatient EP at St. Marys' Medical Center Duluth MN

La description

Inclusion Criteria:

  • Dual chamber pacemaker or ICD device
  • Left Ventrical Ejection Fraction (LVEF) 40% or less
  • Sinus Rhythm with intact atrioventricular conduction with a PR interval greater than 200 msec QRS less than 120 msec
  • Pacing right ventricle lead in the right ventricular apex (RVA), system implanted within 6 weeks or chronically implanted system with histograms showing 20% or less right ventricle pacing

Exclusion Criteria:

  • LVEF greater than 40%,
  • Any rhythm other than sinus rhythm
  • Second degree or higher atrioventricular block
  • Native Heart Rate less than 40 beats per minute or greater than 90 beats per minute
  • Left ventricle or Chronic Sinus lead in non-RVA location
  • Chronically implanted system with greater than 20% right ventricle pacing

Plan d'étude

Cette section fournit des détails sur le plan d'étude, y compris la façon dont l'étude est conçue et ce que l'étude mesure.

Comment l'étude est-elle conçue ?

Détails de conception

Cohortes et interventions

Groupe / Cohorte
Observation
30 Patients with dualchamber pacemakers or implantable cardioverter-defibrillators (ICDs)

Que mesure l'étude ?

Principaux critères de jugement

Mesure des résultats
Acute effect of mechanical dyssynchrony measured by septal to lateral wall delay using tissue doppler imaging between baseline non-fused atrioventricular conduction and varying degrees of paced and native atrioventricular conduction.

Mesures de résultats secondaires

Mesure des résultats
Stroke volume as measured by time velocity integral across the aorta valve between baseline non-fused atrioventricular conduction, and varying degrees of paced and native atrioventricular conduction.

Collaborateurs et enquêteurs

C'est ici que vous trouverez les personnes et les organisations impliquées dans cette étude.

Parrainer

Publications et liens utiles

La personne responsable de la saisie des informations sur l'étude fournit volontairement ces publications. Il peut s'agir de tout ce qui concerne l'étude.

Publications générales

Dates d'enregistrement des études

Ces dates suivent la progression des dossiers d'étude et des soumissions de résultats sommaires à ClinicalTrials.gov. Les dossiers d'étude et les résultats rapportés sont examinés par la Bibliothèque nationale de médecine (NLM) pour s'assurer qu'ils répondent à des normes de contrôle de qualité spécifiques avant d'être publiés sur le site Web public.

Dates principales de l'étude

Début de l'étude

1 janvier 2008

Achèvement primaire (Réel)

1 mai 2010

Achèvement de l'étude (Réel)

1 septembre 2010

Dates d'inscription aux études

Première soumission

25 janvier 2008

Première soumission répondant aux critères de contrôle qualité

6 février 2008

Première publication (Estimation)

8 février 2008

Mises à jour des dossiers d'étude

Dernière mise à jour publiée (Estimation)

2 septembre 2011

Dernière mise à jour soumise répondant aux critères de contrôle qualité

31 août 2011

Dernière vérification

1 août 2011

Plus d'information

Termes liés à cette étude

Termes MeSH pertinents supplémentaires

Autres numéros d'identification d'étude

  • 12-07-02

Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .