Cette page a été traduite automatiquement et l'exactitude de la traduction n'est pas garantie. Veuillez vous référer au version anglaise pour un texte source.

Advanced Visuohaptic Surgical Planning for Trauma Surgery

2 juillet 2020 mis à jour par: VA Office of Research and Development
This study proposes to develop a computer-based software tool that will allow surgeons to plan and simulate surgery for patients with jaw trauma.

Aperçu de l'étude

Statut

Complété

Description détaillée

The proposed tool will allow surgeons from different specialties to simulate, plan and iterate on complex procedures based on individual patient data in 3-D from a CT scan. The software will allow surgeons to both see and feel the results of their interventions - for example, the quality of the bite or bone alignment of a reconstructed jaw following severe trauma - before the actual surgery, leading to better planning, fewer errors, shortened surgery time and improved outcomes for the patients. The purpose of this study is the evaluation of a visuohaptic planning system for mandibular trauma surgery that is based on interactive manipulation of CT data.

Type d'étude

Observationnel

Inscription (Réel)

3

Contacts et emplacements

Cette section fournit les coordonnées de ceux qui mènent l'étude et des informations sur le lieu où cette étude est menée.

Lieux d'étude

    • California
      • San Francisco, California, États-Unis, 94121
        • VA Medical Center, San Francisco

Critères de participation

Les chercheurs recherchent des personnes qui correspondent à une certaine description, appelée critères d'éligibilité. Certains exemples de ces critères sont l'état de santé général d'une personne ou des traitements antérieurs.

Critère d'éligibilité

Âges éligibles pour étudier

18 ans et plus (Adulte, Adulte plus âgé)

Accepte les volontaires sains

Non

Sexes éligibles pour l'étude

Tout

Méthode d'échantillonnage

Échantillon non probabiliste

Population étudiée

Study population will veterans who present to the Oral/Maxillofacial Surgery Clinic at the San Francisco VA Medical Center. The study will use pre-existing data from patients undergoing reconstructive facial surgery at the San Francisco VA with clinic indications that require preoperative CT scans and preoperative radiographs as well as model casts.

La description

Inclusion Criteria:

  • Craniofacial deformity, including post-traumatic, congenital or acquired deformity
  • Patients who have already have surgery because there was a clinical indication for surgical correction

Exclusion Criteria:

  • No craniofacial deformity
  • No clinical indication for surgical correction
  • Contraindication for surgical correction

Plan d'étude

Cette section fournit des détails sur le plan d'étude, y compris la façon dont l'étude est conçue et ce que l'étude mesure.

Comment l'étude est-elle conçue ?

Détails de conception

Cohortes et interventions

Groupe / Cohorte
Intervention / Traitement
Group 1
15 patients who underwent surgical repair of mandibular fractures at San Francisco VA Medical Center
Patients will undergo whatever needed surgical repair of maxillofacial trauma that is necessary. Records such as CT imaging and plaster models of the jaws will be utilized in the standard way to plan and carry out the surgery. The CT scan will also be used within the visuohaptic computational environment to develop and evaluate the user interface. The amount of time taken to work up and plan surgery using standard surgical practice and using the computational platform will be compared. Real surgical outcome will be compared to the simulated surgical outcome using the proposed software tool.

Que mesure l'étude ?

Principaux critères de jugement

Mesure des résultats
Description de la mesure
Délai
Percentage of Deviation From Actual Surgical Outcome During Virtual Repair of Mandibular Fractures, Using the Novel Visuohaptic Computational Platform That Was Developed by the Investigators
Délai: 6 months
The virtual surgical outcome was compared to the actual surgical outcome. This was accomplished by measuring distances (mm) and angles between specific mandibular anatomic points in the virtual environment and comparing it to the same distances (mm) and angles between specific mandibular anatomic points in the actual surgical outcome, as seen in a 3D rendering derived from the patient's postoperative CT scan. The actual surgical repair was considered to be the gold standard. A deviation of more than 10% between the virtual surgical repair and the actual surgical repair was considered to be above threshold (inaccurate virtual fracture repair).
6 months

Mesures de résultats secondaires

Mesure des résultats
Description de la mesure
Délai
Development and Evaluation of Automation Features for the Visuohaptic Virtual Surgery Planning Environment
Délai: 3 years
The addition of automation features for the visuohaptic virtual surgical planning environment was envisioned to make it possible to predict the number, type, size, and position of reconstruction hardware (bone plates and screws) that would best fit the virtually repaired mandibular fractures. The goal was to compare the hardware configuration selected and used in the actual surgical repair for the 3 participating patients with what the software predicted. Unfortunately, the software development proved to be difficult to add this automated feature.
3 years
Implementation and Test of the Telemedicine Prototype
Délai: 3 years
Measurement of the accuracy of the virtual surgical repair generated by the surgeon operating the software when a remote surgeon digitally sends a CT scan of a patient with an acute mandibular fracture(s). The telemedicine interface would require an automated method to segment the CT scan into the fractured components. The operator would manipulate the bone fractures, select the hardware type and size for "best fit", and generate a report back to the remote surgeon.
3 years

Collaborateurs et enquêteurs

C'est ici que vous trouverez les personnes et les organisations impliquées dans cette étude.

Collaborateurs

Les enquêteurs

  • Chercheur principal: Rebeka Silva, DMD, VA Medical Center, San Francisco

Publications et liens utiles

La personne responsable de la saisie des informations sur l'étude fournit volontairement ces publications. Il peut s'agir de tout ce qui concerne l'étude.

Dates d'enregistrement des études

Ces dates suivent la progression des dossiers d'étude et des soumissions de résultats sommaires à ClinicalTrials.gov. Les dossiers d'étude et les résultats rapportés sont examinés par la Bibliothèque nationale de médecine (NLM) pour s'assurer qu'ils répondent à des normes de contrôle de qualité spécifiques avant d'être publiés sur le site Web public.

Dates principales de l'étude

Début de l'étude

1 novembre 2011

Achèvement primaire (Réel)

1 décembre 2014

Achèvement de l'étude (Réel)

1 février 2016

Dates d'inscription aux études

Première soumission

22 janvier 2010

Première soumission répondant aux critères de contrôle qualité

22 janvier 2010

Première publication (Estimation)

26 janvier 2010

Mises à jour des dossiers d'étude

Dernière mise à jour publiée (Réel)

7 juillet 2020

Dernière mise à jour soumise répondant aux critères de contrôle qualité

2 juillet 2020

Dernière vérification

1 juin 2020

Plus d'information

Termes liés à cette étude

Plan pour les données individuelles des participants (IPD)

Prévoyez-vous de partager les données individuelles des participants (DPI) ?

NON

Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .

S'abonner