Advanced Visuohaptic Surgical Planning for Trauma Surgery
2 lipca 2020 zaktualizowane przez: VA Office of Research and Development
This study proposes to develop a computer-based software tool that will allow surgeons to plan and simulate surgery for patients with jaw trauma.
Przegląd badań
Status
Zakończony
Warunki
Interwencja / Leczenie
Szczegółowy opis
The proposed tool will allow surgeons from different specialties to simulate, plan and iterate on complex procedures based on individual patient data in 3-D from a CT scan.
The software will allow surgeons to both see and feel the results of their interventions - for example, the quality of the bite or bone alignment of a reconstructed jaw following severe trauma - before the actual surgery, leading to better planning, fewer errors, shortened surgery time and improved outcomes for the patients.
The purpose of this study is the evaluation of a visuohaptic planning system for mandibular trauma surgery that is based on interactive manipulation of CT data.
Typ studiów
Obserwacyjny
Zapisy (Rzeczywisty)
3
Kontakty i lokalizacje
Ta sekcja zawiera dane kontaktowe osób prowadzących badanie oraz informacje o tym, gdzie badanie jest przeprowadzane.
Lokalizacje studiów
-
-
California
-
San Francisco, California, Stany Zjednoczone, 94121
- VA Medical Center, San Francisco
-
-
Kryteria uczestnictwa
Badacze szukają osób, które pasują do określonego opisu, zwanego kryteriami kwalifikacyjnymi. Niektóre przykłady tych kryteriów to ogólny stan zdrowia danej osoby lub wcześniejsze leczenie.
Kryteria kwalifikacji
Wiek uprawniający do nauki
18 lat i starsze (Dorosły, Starszy dorosły)
Akceptuje zdrowych ochotników
Nie
Płeć kwalifikująca się do nauki
Wszystko
Metoda próbkowania
Próbka bez prawdopodobieństwa
Badana populacja
Study population will veterans who present to the Oral/Maxillofacial Surgery Clinic at the San Francisco VA Medical Center.
The study will use pre-existing data from patients undergoing reconstructive facial surgery at the San Francisco VA with clinic indications that require preoperative CT scans and preoperative radiographs as well as model casts.
Opis
Inclusion Criteria:
- Craniofacial deformity, including post-traumatic, congenital or acquired deformity
- Patients who have already have surgery because there was a clinical indication for surgical correction
Exclusion Criteria:
- No craniofacial deformity
- No clinical indication for surgical correction
- Contraindication for surgical correction
Plan studiów
Ta sekcja zawiera szczegółowe informacje na temat planu badania, w tym sposób zaprojektowania badania i jego pomiary.
Jak projektuje się badanie?
Szczegóły projektu
Kohorty i interwencje
Grupa / Kohorta |
Interwencja / Leczenie |
|---|---|
|
Group 1
15 patients who underwent surgical repair of mandibular fractures at San Francisco VA Medical Center
|
Patients will undergo whatever needed surgical repair of maxillofacial trauma that is necessary.
Records such as CT imaging and plaster models of the jaws will be utilized in the standard way to plan and carry out the surgery.
The CT scan will also be used within the visuohaptic computational environment to develop and evaluate the user interface.
The amount of time taken to work up and plan surgery using standard surgical practice and using the computational platform will be compared.
Real surgical outcome will be compared to the simulated surgical outcome using the proposed software tool.
|
Co mierzy badanie?
Podstawowe miary wyniku
Miara wyniku |
Opis środka |
Ramy czasowe |
|---|---|---|
|
Percentage of Deviation From Actual Surgical Outcome During Virtual Repair of Mandibular Fractures, Using the Novel Visuohaptic Computational Platform That Was Developed by the Investigators
Ramy czasowe: 6 months
|
The virtual surgical outcome was compared to the actual surgical outcome.
This was accomplished by measuring distances (mm) and angles between specific mandibular anatomic points in the virtual environment and comparing it to the same distances (mm) and angles between specific mandibular anatomic points in the actual surgical outcome, as seen in a 3D rendering derived from the patient's postoperative CT scan.
The actual surgical repair was considered to be the gold standard.
A deviation of more than 10% between the virtual surgical repair and the actual surgical repair was considered to be above threshold (inaccurate virtual fracture repair).
|
6 months
|
Miary wyników drugorzędnych
Miara wyniku |
Opis środka |
Ramy czasowe |
|---|---|---|
|
Development and Evaluation of Automation Features for the Visuohaptic Virtual Surgery Planning Environment
Ramy czasowe: 3 years
|
The addition of automation features for the visuohaptic virtual surgical planning environment was envisioned to make it possible to predict the number, type, size, and position of reconstruction hardware (bone plates and screws) that would best fit the virtually repaired mandibular fractures.
The goal was to compare the hardware configuration selected and used in the actual surgical repair for the 3 participating patients with what the software predicted.
Unfortunately, the software development proved to be difficult to add this automated feature.
|
3 years
|
|
Implementation and Test of the Telemedicine Prototype
Ramy czasowe: 3 years
|
Measurement of the accuracy of the virtual surgical repair generated by the surgeon operating the software when a remote surgeon digitally sends a CT scan of a patient with an acute mandibular fracture(s).
The telemedicine interface would require an automated method to segment the CT scan into the fractured components.
The operator would manipulate the bone fractures, select the hardware type and size for "best fit", and generate a report back to the remote surgeon.
|
3 years
|
Współpracownicy i badacze
Tutaj znajdziesz osoby i organizacje zaangażowane w to badanie.
Współpracownicy
Śledczy
- Główny śledczy: Rebeka Silva, DMD, VA Medical Center, San Francisco
Publikacje i pomocne linki
Osoba odpowiedzialna za wprowadzenie informacji o badaniu dobrowolnie udostępnia te publikacje. Mogą one dotyczyć wszystkiego, co jest związane z badaniem.
Publikacje ogólne
- Schvartzman SC, Silva R, Salisbury K, Gaudilliere D, Girod S. Computer-aided trauma simulation system with haptic feedback is easy and fast for oral-maxillofacial surgeons to learn and use. J Oral Maxillofac Surg. 2014 Oct;72(10):1984-93. doi: 10.1016/j.joms.2014.05.007. Epub 2014 May 24.
- Forsslund J, Chan S, Selesnick J, Salisbury K, Silva RG, Blevins NH. The effect of haptic degrees of freedom on task performance in virtual surgical environments. Stud Health Technol Inform. 2013;184:129-35.
- Girod S, Schvartzman SC, Gaudilliere D, Salisbury K, Silva R. Haptic feedback improves surgeons' user experience and fracture reduction in facial trauma simulation. J Rehabil Res Dev. 2016;53(5):561-570. doi: 10.1682/JRRD.2015.03.0043.
Daty zapisu na studia
Daty te śledzą postęp w przesyłaniu rekordów badań i podsumowań wyników do ClinicalTrials.gov. Zapisy badań i zgłoszone wyniki są przeglądane przez National Library of Medicine (NLM), aby upewnić się, że spełniają określone standardy kontroli jakości, zanim zostaną opublikowane na publicznej stronie internetowej.
Główne daty studiów
Rozpoczęcie studiów
1 listopada 2011
Zakończenie podstawowe (Rzeczywisty)
1 grudnia 2014
Ukończenie studiów (Rzeczywisty)
1 lutego 2016
Daty rejestracji na studia
Pierwszy przesłany
22 stycznia 2010
Pierwszy przesłany, który spełnia kryteria kontroli jakości
22 stycznia 2010
Pierwszy wysłany (Oszacować)
26 stycznia 2010
Aktualizacje rekordów badań
Ostatnia wysłana aktualizacja (Rzeczywisty)
7 lipca 2020
Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości
2 lipca 2020
Ostatnia weryfikacja
1 czerwca 2020
Więcej informacji
Terminy związane z tym badaniem
Słowa kluczowe
Dodatkowe istotne warunki MeSH
Inne numery identyfikacyjne badania
- F7124-R
Plan dla danych uczestnika indywidualnego (IPD)
Planujesz udostępniać dane poszczególnych uczestników (IPD)?
NIE
Te informacje zostały pobrane bezpośrednio ze strony internetowej clinicaltrials.gov bez żadnych zmian. Jeśli chcesz zmienić, usunąć lub zaktualizować dane swojego badania, skontaktuj się z register@clinicaltrials.gov. Gdy tylko zmiana zostanie wprowadzona na stronie clinicaltrials.gov, zostanie ona automatycznie zaktualizowana również na naszej stronie internetowej .