- ICH GCP
- Register voor klinische proeven in de VS.
- Klinische proef NCT01056302
Advanced Visuohaptic Surgical Planning for Trauma Surgery
2 juli 2020 bijgewerkt door: VA Office of Research and Development
This study proposes to develop a computer-based software tool that will allow surgeons to plan and simulate surgery for patients with jaw trauma.
Studie Overzicht
Toestand
Voltooid
Conditie
Interventie / Behandeling
Gedetailleerde beschrijving
The proposed tool will allow surgeons from different specialties to simulate, plan and iterate on complex procedures based on individual patient data in 3-D from a CT scan.
The software will allow surgeons to both see and feel the results of their interventions - for example, the quality of the bite or bone alignment of a reconstructed jaw following severe trauma - before the actual surgery, leading to better planning, fewer errors, shortened surgery time and improved outcomes for the patients.
The purpose of this study is the evaluation of a visuohaptic planning system for mandibular trauma surgery that is based on interactive manipulation of CT data.
Studietype
Observationeel
Inschrijving (Werkelijk)
3
Contacten en locaties
In dit gedeelte vindt u de contactgegevens van degenen die het onderzoek uitvoeren en informatie over waar dit onderzoek wordt uitgevoerd.
Studie Locaties
-
-
California
-
San Francisco, California, Verenigde Staten, 94121
- VA Medical Center, San Francisco
-
-
Deelname Criteria
Onderzoekers zoeken naar mensen die aan een bepaalde beschrijving voldoen, de zogenaamde geschiktheidscriteria. Enkele voorbeelden van deze criteria zijn iemands algemene gezondheidstoestand of eerdere behandelingen.
Geschiktheidscriteria
Leeftijden die in aanmerking komen voor studie
18 jaar en ouder (Volwassen, Oudere volwassene)
Accepteert gezonde vrijwilligers
Nee
Geslachten die in aanmerking komen voor studie
Allemaal
Bemonsteringsmethode
Niet-waarschijnlijkheidssteekproef
Studie Bevolking
Study population will veterans who present to the Oral/Maxillofacial Surgery Clinic at the San Francisco VA Medical Center.
The study will use pre-existing data from patients undergoing reconstructive facial surgery at the San Francisco VA with clinic indications that require preoperative CT scans and preoperative radiographs as well as model casts.
Beschrijving
Inclusion Criteria:
- Craniofacial deformity, including post-traumatic, congenital or acquired deformity
- Patients who have already have surgery because there was a clinical indication for surgical correction
Exclusion Criteria:
- No craniofacial deformity
- No clinical indication for surgical correction
- Contraindication for surgical correction
Studie plan
Dit gedeelte bevat details van het studieplan, inclusief hoe de studie is opgezet en wat de studie meet.
Hoe is de studie opgezet?
Ontwerpdetails
Cohorten en interventies
Groep / Cohort |
Interventie / Behandeling |
|---|---|
|
Group 1
15 patients who underwent surgical repair of mandibular fractures at San Francisco VA Medical Center
|
Patients will undergo whatever needed surgical repair of maxillofacial trauma that is necessary.
Records such as CT imaging and plaster models of the jaws will be utilized in the standard way to plan and carry out the surgery.
The CT scan will also be used within the visuohaptic computational environment to develop and evaluate the user interface.
The amount of time taken to work up and plan surgery using standard surgical practice and using the computational platform will be compared.
Real surgical outcome will be compared to the simulated surgical outcome using the proposed software tool.
|
Wat meet het onderzoek?
Primaire uitkomstmaten
Uitkomstmaat |
Maatregel Beschrijving |
Tijdsspanne |
|---|---|---|
|
Percentage of Deviation From Actual Surgical Outcome During Virtual Repair of Mandibular Fractures, Using the Novel Visuohaptic Computational Platform That Was Developed by the Investigators
Tijdsspanne: 6 months
|
The virtual surgical outcome was compared to the actual surgical outcome.
This was accomplished by measuring distances (mm) and angles between specific mandibular anatomic points in the virtual environment and comparing it to the same distances (mm) and angles between specific mandibular anatomic points in the actual surgical outcome, as seen in a 3D rendering derived from the patient's postoperative CT scan.
The actual surgical repair was considered to be the gold standard.
A deviation of more than 10% between the virtual surgical repair and the actual surgical repair was considered to be above threshold (inaccurate virtual fracture repair).
|
6 months
|
Secundaire uitkomstmaten
Uitkomstmaat |
Maatregel Beschrijving |
Tijdsspanne |
|---|---|---|
|
Development and Evaluation of Automation Features for the Visuohaptic Virtual Surgery Planning Environment
Tijdsspanne: 3 years
|
The addition of automation features for the visuohaptic virtual surgical planning environment was envisioned to make it possible to predict the number, type, size, and position of reconstruction hardware (bone plates and screws) that would best fit the virtually repaired mandibular fractures.
The goal was to compare the hardware configuration selected and used in the actual surgical repair for the 3 participating patients with what the software predicted.
Unfortunately, the software development proved to be difficult to add this automated feature.
|
3 years
|
|
Implementation and Test of the Telemedicine Prototype
Tijdsspanne: 3 years
|
Measurement of the accuracy of the virtual surgical repair generated by the surgeon operating the software when a remote surgeon digitally sends a CT scan of a patient with an acute mandibular fracture(s).
The telemedicine interface would require an automated method to segment the CT scan into the fractured components.
The operator would manipulate the bone fractures, select the hardware type and size for "best fit", and generate a report back to the remote surgeon.
|
3 years
|
Medewerkers en onderzoekers
Hier vindt u mensen en organisaties die betrokken zijn bij dit onderzoek.
Medewerkers
Onderzoekers
- Hoofdonderzoeker: Rebeka Silva, DMD, VA Medical Center, San Francisco
Publicaties en nuttige links
De persoon die verantwoordelijk is voor het invoeren van informatie over het onderzoek stelt deze publicaties vrijwillig ter beschikking. Dit kan gaan over alles wat met het onderzoek te maken heeft.
Algemene publicaties
- Schvartzman SC, Silva R, Salisbury K, Gaudilliere D, Girod S. Computer-aided trauma simulation system with haptic feedback is easy and fast for oral-maxillofacial surgeons to learn and use. J Oral Maxillofac Surg. 2014 Oct;72(10):1984-93. doi: 10.1016/j.joms.2014.05.007. Epub 2014 May 24.
- Forsslund J, Chan S, Selesnick J, Salisbury K, Silva RG, Blevins NH. The effect of haptic degrees of freedom on task performance in virtual surgical environments. Stud Health Technol Inform. 2013;184:129-35.
- Girod S, Schvartzman SC, Gaudilliere D, Salisbury K, Silva R. Haptic feedback improves surgeons' user experience and fracture reduction in facial trauma simulation. J Rehabil Res Dev. 2016;53(5):561-570. doi: 10.1682/JRRD.2015.03.0043.
Studie record data
Deze datums volgen de voortgang van het onderzoeksdossier en de samenvatting van de ingediende resultaten bij ClinicalTrials.gov. Studieverslagen en gerapporteerde resultaten worden beoordeeld door de National Library of Medicine (NLM) om er zeker van te zijn dat ze voldoen aan specifieke kwaliteitscontrolenormen voordat ze op de openbare website worden geplaatst.
Bestudeer belangrijke data
Studie start
1 november 2011
Primaire voltooiing (Werkelijk)
1 december 2014
Studie voltooiing (Werkelijk)
1 februari 2016
Studieregistratiedata
Eerst ingediend
22 januari 2010
Eerst ingediend dat voldeed aan de QC-criteria
22 januari 2010
Eerst geplaatst (Schatting)
26 januari 2010
Updates van studierecords
Laatste update geplaatst (Werkelijk)
7 juli 2020
Laatste update ingediend die voldeed aan QC-criteria
2 juli 2020
Laatst geverifieerd
1 juni 2020
Meer informatie
Termen gerelateerd aan deze studie
Trefwoorden
Aanvullende relevante MeSH-voorwaarden
Andere studie-ID-nummers
- F7124-R
Plan Individuele Deelnemersgegevens (IPD)
Bent u van plan om gegevens van individuele deelnemers (IPD) te delen?
NEE
Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .