Comparing Pleth Variability Index (PVI) Measurements at Different Sensing Locations
24 mars 2021 mis à jour par: University of California, Irvine
Comparing PVI Measurements at Different Sensing Locations
The purpose of this study is to assess the suitability of the ear and forehead as a better site for measure of fluid responsiveness.
Aperçu de l'étude
Statut
Complété
Les conditions
Description détaillée
The aim of this study is to compare Pleth Variability Index (PVI) measurements at different sensor locations in respect to signal quality, sensor fit to site location and fluid responsiveness.
PVI will be measured at 3 different sensor sites: the fingers, ear lobes and forehead.
The ability to predict fluid responsiveness will be analyzed using cardiac output as the reference value.
Type d'étude
Observationnel
Inscription (Réel)
35
Contacts et emplacements
Cette section fournit les coordonnées de ceux qui mènent l'étude et des informations sur le lieu où cette étude est menée.
Lieux d'étude
-
-
California
-
Orange, California, États-Unis, 92868
- University of California, Irvine Medical Center
-
-
Critères de participation
Les chercheurs recherchent des personnes qui correspondent à une certaine description, appelée critères d'éligibilité. Certains exemples de ces critères sont l'état de santé général d'une personne ou des traitements antérieurs.
Critère d'éligibilité
Âges éligibles pour étudier
18 ans et plus (Adulte, Adulte plus âgé)
Accepte les volontaires sains
Non
Sexes éligibles pour l'étude
Tout
Méthode d'échantillonnage
Échantillon non probabiliste
Population étudiée
The study population will be patients who undergo any form of surgery, where he/she is mechanically ventilated, preferably cases that require arterial line placement, use of cardiac output measurement, and where fluid administration will occur perioperatively.
La description
Inclusion Criteria:
- 18 years of age or older
- Undergo any type of surgeries under general anesthesia in UCI Medical Center
- Mechanically ventilated during surgery
- Arterial line placement is preferred but not required
- Agree to sign the consent and HIPAA forms
Exclusion Criteria:
- Less than 18 years of age
- Pregnant women
- Refused to sign the consent and HIPAA forms
- Receive vasoactive medication prior to surgery
- Has these conditions: hypotension, hypothyroidism, moderate or poorly controlled hypertension, chronic poorly-controlled diabetes, heart failure patients, and patients with active airway flow obstruction, left ventricular dysfunction, intra-cardiac shunts, right ventricular dysfunction, atrial fibrillation, arrhythmias
- patients with surgeries at or around site of sensor placement
- Subject has skin abnormalities affecting the digits such as psoriasis, eczema, angioma, scar tissue, burn, fungal infection, substantial skin breakdown, nail polish or acrylic nails that would prevent monitoring of SpO2 levels during the study
Plan d'étude
Cette section fournit des détails sur le plan d'étude, y compris la façon dont l'étude est conçue et ce que l'étude mesure.
Comment l'étude est-elle conçue ?
Détails de conception
Que mesure l'étude ?
Principaux critères de jugement
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
PVI measurement of fluid responsiveness
Délai: Intra-operative
|
The primary outcome is to test the ability of PVI recorded at the finger and at the ear to predict fluid responsiveness.
|
Intra-operative
|
Collaborateurs et enquêteurs
C'est ici que vous trouverez les personnes et les organisations impliquées dans cette étude.
Parrainer
Collaborateurs
Les enquêteurs
- Chercheur principal: Maxime Cannesson, PhD, UC Irvine
Publications et liens utiles
La personne responsable de la saisie des informations sur l'étude fournit volontairement ces publications. Il peut s'agir de tout ce qui concerne l'étude.
Publications générales
- Cannesson M, Delannoy B, Morand A, Rosamel P, Attof Y, Bastien O, Lehot JJ. Does the Pleth variability index indicate the respiratory-induced variation in the plethysmogram and arterial pressure waveforms? Anesth Analg. 2008 Apr;106(4):1189-94, table of contents. doi: 10.1213/ane.0b013e318167ab1f.
- Cannesson M, Desebbe O, Rosamel P, Delannoy B, Robin J, Bastien O, Lehot JJ. Pleth variability index to monitor the respiratory variations in the pulse oximeter plethysmographic waveform amplitude and predict fluid responsiveness in the operating theatre. Br J Anaesth. 2008 Aug;101(2):200-6. doi: 10.1093/bja/aen133. Epub 2008 Jun 2.
- Shelley KH, Jablonka DH, Awad AA, Stout RG, Rezkanna H, Silverman DG. What is the best site for measuring the effect of ventilation on the pulse oximeter waveform? Anesth Analg. 2006 Aug;103(2):372-7, table of contents. doi: 10.1213/01.ane.0000222477.67637.17.
- Cannesson M, Besnard C, Durand PG, Bohe J, Jacques D. Relation between respiratory variations in pulse oximetry plethysmographic waveform amplitude and arterial pulse pressure in ventilated patients. Crit Care. 2005 Oct 5;9(5):R562-8. doi: 10.1186/cc3799. Epub 2005 Aug 23.
- Feissel M, Teboul JL, Merlani P, Badie J, Faller JP, Bendjelid K. Plethysmographic dynamic indices predict fluid responsiveness in septic ventilated patients. Intensive Care Med. 2007 Jun;33(6):993-9. doi: 10.1007/s00134-007-0602-6. Epub 2007 Mar 29.
- Cannesson M, Attof Y, Rosamel P, Desebbe O, Joseph P, Metton O, Bastien O, Lehot JJ. Respiratory variations in pulse oximetry plethysmographic waveform amplitude to predict fluid responsiveness in the operating room. Anesthesiology. 2007 Jun;106(6):1105-11. doi: 10.1097/01.anes.0000267593.72744.20.
- Hood JA, Wilson RJ. Pleth variability index to predict fluid responsiveness in colorectal surgery. Anesth Analg. 2011 Nov;113(5):1058-63. doi: 10.1213/ANE.0b013e31822c10cd. Epub 2011 Sep 30.
Dates d'enregistrement des études
Ces dates suivent la progression des dossiers d'étude et des soumissions de résultats sommaires à ClinicalTrials.gov. Les dossiers d'étude et les résultats rapportés sont examinés par la Bibliothèque nationale de médecine (NLM) pour s'assurer qu'ils répondent à des normes de contrôle de qualité spécifiques avant d'être publiés sur le site Web public.
Dates principales de l'étude
Début de l'étude
1 avril 2014
Achèvement primaire (Réel)
1 juillet 2017
Achèvement de l'étude (Réel)
1 juillet 2017
Dates d'inscription aux études
Première soumission
24 avril 2014
Première soumission répondant aux critères de contrôle qualité
25 avril 2014
Première publication (Estimation)
28 avril 2014
Mises à jour des dossiers d'étude
Dernière mise à jour publiée (Réel)
29 mars 2021
Dernière mise à jour soumise répondant aux critères de contrôle qualité
24 mars 2021
Dernière vérification
1 mars 2021
Plus d'information
Termes liés à cette étude
Mots clés
Autres numéros d'identification d'étude
- UCIANES05
Plan pour les données individuelles des participants (IPD)
Prévoyez-vous de partager les données individuelles des participants (DPI) ?
INDÉCIS
Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .