Post-market Clinical Follow-up Study With Magnetic Resonance Imaging Conditional Guide Wire (MRWIREPMCF)
Aperçu de l'étude
Statut
Les conditions
Intervention / Traitement
Description détaillée
This is post-market clinical follow-up study on 25 consecutive patients in two centers to evaluate the safety of a guide wire conditional for use in magnetic resonance imaging and the acceptability of identified risks in the clinical evaluation and to detect emerging risks on the basis of factorial evidence.
The guidewire is used to access the patients central circulatory system and in particular for the introduction and exact placement of a pressure catheter to measure the pressure gradient over the aortic arch. The procedure will be done in patients with a clinical indication for cardiac magnetic resonance and conventional catheterisation.Patients need to have a body weight over 40 kg and the introduction of a 5 French catheter should be possible. The primary endpoint is the measurement of procedural success, defined as successful insertion, steerability and visibility in MRI, in the absence of device related adverse events such as damage to vessel wall. In addition structural integrity of the instruments is to be assessed.
Type d'étude
Inscription (Réel)
Phase
- N'est pas applicable
Contacts et emplacements
Lieux d'étude
-
-
-
Leipzig, Allemagne, 04289
- Herzzentrum Leipzig
-
-
Bavaria
-
Munich, Bavaria, Allemagne, 80636
- Deutsches Herzzentrum München
-
-
-
-
-
London, Royaume-Uni, WC1N 1EH
- Royal Free Hospital- Great Ormond Street Hospital
-
-
Critères de participation
Critère d'éligibilité
Âges éligibles pour étudier
- Enfant
- Adulte
- Adulte plus âgé
Accepte les volontaires sains
Sexes éligibles pour l'étude
La description
Inclusion Criteria:
- patients with clinical indication for cardiac magnetic resonance and conventional diagnostic catheterisation
- patients with body weight of > 40 kg in which the introduction of an introducer of > 5 French is possible.
- subject provided written informed consent using the approved consent form or in case of a minor the subject provided written assent and its legal guardian provided written informed consent.
Exclusion Criteria:
- major surgery in the last 42 days
- history of irreversible bleeding disorder
- contraindication to cardiac magnetic resonance
- Contraindications to guidewire procedures, such as evidence of active infection
- women of child-bearing potential who cannot provide a negative pregnancy test
- chronic total occlusion.
Plan d'étude
Comment l'étude est-elle conçue ?
Détails de conception
- Objectif principal: Diagnostique
- Répartition: N / A
- Modèle interventionnel: Affectation à un seul groupe
- Masquage: Aucun (étiquette ouverte)
Armes et Interventions
Groupe de participants / Bras |
Intervention / Traitement |
|---|---|
|
Autre: pressure gradient measurement
Diagnostic procedure to measure pressure gradient in series of patients.
Focus is on safety and absence of adverse events
|
A guidewire is used to introduce and position a pressure catheter under magnetic resonance guidance to conduct flow and pressure measurement in the aortic arch to evaluate vascular resistance.
Autres noms:
|
Que mesure l'étude ?
Principaux critères de jugement
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
Procedural success
Délai: Up to 30 days after procedure
|
procedural success means that insertion, steerability and visibility of the guide wire in the MR guided intervention was successfully reached, in the absence of adverse events up to 30 days after procedure
|
Up to 30 days after procedure
|
Collaborateurs et enquêteurs
Parrainer
Collaborateurs
Les enquêteurs
- Chercheur principal: Peter Ewert, Prof, MD, German Heart Center
Publications et liens utiles
Publications générales
- Kos S, Huegli R, Hofmann E, Quick HH, Kuehl H, Aker S, Kaiser GM, Borm PJ, Jacob AL, Bilecen D. First magnetic resonance imaging-guided aortic stenting and cava filter placement using a polyetheretherketone-based magnetic resonance imaging-compatible guidewire in swine: proof of concept. Cardiovasc Intervent Radiol. 2009 May;32(3):514-21. doi: 10.1007/s00270-008-9483-5. Epub 2008 Dec 30.
- Kos S, Huegli R, Hofmann E, Quick HH, Kuehl H, Aker S, Kaiser GM, Borm PJ, Jacob AL, Bilecen D. MR-compatible polyetheretherketone-based guide wire assisting MR-guided stenting of iliac and supraaortic arteries in swine: feasibility study. Minim Invasive Ther Allied Technol. 2009;18(3):181-8. doi: 10.1080/13645700902921971.
- Kos S, Huegli R, Hofmann E, Quick HH, Kuehl H, Aker S, Kaiser GM, Borm PJ, Jacob AL, Bilecen D. Feasibility of real-time magnetic resonance-guided angioplasty and stenting of renal arteries in vitro and in Swine, using a new polyetheretherketone-based magnetic resonance-compatible guidewire. Invest Radiol. 2009 Apr;44(4):234-41. doi: 10.1097/RLI.0b013e31819b00f1.
Dates d'enregistrement des études
Dates principales de l'étude
Début de l'étude
Achèvement primaire (Réel)
Achèvement de l'étude (Réel)
Dates d'inscription aux études
Première soumission
Première soumission répondant aux critères de contrôle qualité
Première publication (Estimation)
Mises à jour des dossiers d'étude
Dernière mise à jour publiée (Réel)
Dernière mise à jour soumise répondant aux critères de contrôle qualité
Dernière vérification
Plus d'information
Termes liés à cette étude
Mots clés
Termes MeSH pertinents supplémentaires
Autres numéros d'identification d'étude
- N4IPMCF2015
Plan pour les données individuelles des participants (IPD)
Prévoyez-vous de partager les données individuelles des participants (DPI) ?
Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .