Intra-operative Feed Back on Traction Force During Vacuum Extraction: Safe Vacuum Extraction Alliance (SVEA)
Intra-operative Feed Back on Traction Force During Vacuum Extraction: a Randomized Control Study of Mid and Low Metal Cup Deliveries.
The objective of the clinical investigation is to test whether intra-operative traction force feed back during vacuum extraction leads to a significant decrease in incidence of brain damage in neonates.
By randomization, half of the vacuum extraction patients will be assigned to delivery using a new intelligent handle for vacuum extractions, and half will be assigned to conventional method without traction force measurement.
Aperçu de l'étude
Statut
Intervention / Traitement
Description détaillée
The most common indications for vacuum extraction are dystocia and/or fetal asphyxia. The safety of assisted vaginal delivery with vacuum extraction has been discussed since its introduction almost fifty years ago. Serious complications such as asphyxia, intracranial hemorrhage and seizures are overrepresented at vacuum extraction compared to spontaneous vaginal delivery.
Little has been done to improve the procedure since the introduction. Safety measures recommended include restricting total time and number of pulls, a full 34 week gestation, and station of the head at the spines or below. A general advice is also to avoid excessive traction force. There is no general agreement to what a safe traction force might be. With exceeding force there seems to be an increased risk for rupture of the sagittal sinus and tearing of the falx at its attachment to the tentorium. Furthermore, when the fetal head is becoming exceedingly elongated and flattened, and as the cup pops off it might cause damage to the brain and blood vessels.
During the procedure the obstetrician is under significant stress and the subjective element of the evaluation of traction force is a concern. The difficult decision of whether to continue a heavy extraction or abort the operation is made under stressful conditions and based mostly on subjective impressions.
To provide the obstetrician with more objective information, the investigators developed a new device consisting of an intelligent handle hooked to the chain of a regular metal cup.
Type d'étude
Inscription (Réel)
Phase
- N'est pas applicable
Contacts et emplacements
Lieux d'étude
-
-
-
Stockholm, Suède, 14186
- Karolinska University Hospital
-
-
Critères de participation
Critère d'éligibilité
Âges éligibles pour étudier
- Enfant
- Adulte
- Adulte plus âgé
Accepte les volontaires sains
Sexes éligibles pour l'étude
La description
Inclusion Criteria:
- Medical or social reasons for vacuum extraction with a metal cup, gestational age ≥37+0 weeks, singleton, cephalic
Exclusion Criteria:
- Multiple pregnancy, breech presentation, gestational age <37+0
Plan d'étude
Comment l'étude est-elle conçue ?
Détails de conception
- Objectif principal: La prévention
- Répartition: Randomisé
- Modèle interventionnel: Affectation parallèle
- Masquage: Seul
Armes et Interventions
Groupe de participants / Bras |
Intervention / Traitement |
---|---|
Expérimental: Vacuum extraction intelligent system
Measurement and intra-operative feed back of vacuum extraction data: notification signal based an algorithm calculation using traction force (peak and time force integral) and time.
|
Vacuum extraction intelligent system - this is the intervention
|
Aucune intervention: conventional
conventional handle
|
Que mesure l'étude ?
Principaux critères de jugement
Mesure des résultats |
Description de la mesure |
Délai |
---|---|---|
Composite neonatal brain damage
Délai: From start of extraction through 28 days after delivery (or until discharge from the hospital)
|
Composite consists of: Hypoxic ischemic encephalopathy (HIE), intracranial hemorrhage (ICH), seizures, perinatal mortality and subgaleal hematoma as routinely diagnosed in patient chart
|
From start of extraction through 28 days after delivery (or until discharge from the hospital)
|
Collaborateurs et enquêteurs
Parrainer
Les enquêteurs
- Chercheur principal: Magnus Westgren, Professor, Karolinska Institutet
Publications et liens utiles
Publications générales
- MALMSTROM T. The vacuum extractor, an obstetrical instrument. I. Acta Obstet Gynecol Scand Suppl. 1957;36(suppl 3):5-50. No abstract available.
- Moolgaoker AS, Ahamed SO, Payne PR. A comparison of different methods of instrumental delivery based on electronic measurements of compression and traction. Obstet Gynecol. 1979 Sep;54(3):299-309.
- Towner DR, Ciotti MC. Operative vaginal delivery: a cause of birth injury or is it? Clin Obstet Gynecol. 2007 Sep;50(3):563-81. doi: 10.1097/GRF.0b013e31811eaa39.
- Whitby EH, Griffiths PD, Rutter S, Smith MF, Sprigg A, Ohadike P, Davies NP, Rigby AS, Paley MN. Frequency and natural history of subdural haemorrhages in babies and relation to obstetric factors. Lancet. 2004 Mar 13;363(9412):846-51. doi: 10.1016/S0140-6736(04)15730-9.
- Pettersson K, Ajne J, Yousaf K, Sturm D, Westgren M, Ajne G. Traction force during vacuum extraction: a prospective observational study. BJOG. 2015 Dec;122(13):1809-16. doi: 10.1111/1471-0528.13222. Epub 2015 Jan 5.
- Romero S, Pettersson K, Yousaf K, Westgren M, Ajne G. Perinatal outcome after vacuum assisted delivery with digital feedback on traction force; a randomised controlled study. BMC Pregnancy Childbirth. 2021 Feb 26;21(1):165. doi: 10.1186/s12884-021-03604-z.
Dates d'enregistrement des études
Dates principales de l'étude
Début de l'étude
Achèvement primaire (Réel)
Achèvement de l'étude (Réel)
Dates d'inscription aux études
Première soumission
Première soumission répondant aux critères de contrôle qualité
Première publication (Réel)
Mises à jour des dossiers d'étude
Dernière mise à jour publiée (Réel)
Dernière mise à jour soumise répondant aux critères de contrôle qualité
Dernière vérification
Plus d'information
Termes liés à cette étude
Termes MeSH pertinents supplémentaires
- Processus pathologiques
- Maladies cardiovasculaires
- Maladies vasculaires
- Troubles cérébrovasculaires
- Maladies du système nerveux central
- Maladies du système nerveux
- Manifestations neurologiques
- Hémorragie
- Signes et symptômes respiratoires
- Hypoxie
- Hypoxie, Cerveau
- Ischémie cérébrale
- Saisies
- Maladies du cerveau
- Hypoxie-ischémie, cerveau
- Hématome
Autres numéros d'identification d'étude
- KI-Clintec-SVEA
Plan pour les données individuelles des participants (IPD)
Prévoyez-vous de partager les données individuelles des participants (DPI) ?
Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .