- ICH GCP
- Register voor klinische proeven in de VS.
- Klinische proef NCT03071783
Intra-operative Feed Back on Traction Force During Vacuum Extraction: Safe Vacuum Extraction Alliance (SVEA)
Intra-operative Feed Back on Traction Force During Vacuum Extraction: a Randomized Control Study of Mid and Low Metal Cup Deliveries.
The objective of the clinical investigation is to test whether intra-operative traction force feed back during vacuum extraction leads to a significant decrease in incidence of brain damage in neonates.
By randomization, half of the vacuum extraction patients will be assigned to delivery using a new intelligent handle for vacuum extractions, and half will be assigned to conventional method without traction force measurement.
Studie Overzicht
Toestand
Interventie / Behandeling
Gedetailleerde beschrijving
The most common indications for vacuum extraction are dystocia and/or fetal asphyxia. The safety of assisted vaginal delivery with vacuum extraction has been discussed since its introduction almost fifty years ago. Serious complications such as asphyxia, intracranial hemorrhage and seizures are overrepresented at vacuum extraction compared to spontaneous vaginal delivery.
Little has been done to improve the procedure since the introduction. Safety measures recommended include restricting total time and number of pulls, a full 34 week gestation, and station of the head at the spines or below. A general advice is also to avoid excessive traction force. There is no general agreement to what a safe traction force might be. With exceeding force there seems to be an increased risk for rupture of the sagittal sinus and tearing of the falx at its attachment to the tentorium. Furthermore, when the fetal head is becoming exceedingly elongated and flattened, and as the cup pops off it might cause damage to the brain and blood vessels.
During the procedure the obstetrician is under significant stress and the subjective element of the evaluation of traction force is a concern. The difficult decision of whether to continue a heavy extraction or abort the operation is made under stressful conditions and based mostly on subjective impressions.
To provide the obstetrician with more objective information, the investigators developed a new device consisting of an intelligent handle hooked to the chain of a regular metal cup.
Studietype
Inschrijving (Werkelijk)
Fase
- Niet toepasbaar
Contacten en locaties
Studie Locaties
-
-
-
Stockholm, Zweden, 14186
- Karolinska University Hospital
-
-
Deelname Criteria
Geschiktheidscriteria
Leeftijden die in aanmerking komen voor studie
- Kind
- Volwassen
- Oudere volwassene
Accepteert gezonde vrijwilligers
Geslachten die in aanmerking komen voor studie
Beschrijving
Inclusion Criteria:
- Medical or social reasons for vacuum extraction with a metal cup, gestational age ≥37+0 weeks, singleton, cephalic
Exclusion Criteria:
- Multiple pregnancy, breech presentation, gestational age <37+0
Studie plan
Hoe is de studie opgezet?
Ontwerpdetails
- Primair doel: Preventie
- Toewijzing: Gerandomiseerd
- Interventioneel model: Parallelle opdracht
- Masker: Enkel
Wapens en interventies
Deelnemersgroep / Arm |
Interventie / Behandeling |
|---|---|
|
Experimenteel: Vacuum extraction intelligent system
Measurement and intra-operative feed back of vacuum extraction data: notification signal based an algorithm calculation using traction force (peak and time force integral) and time.
|
Vacuum extraction intelligent system - this is the intervention
|
|
Geen tussenkomst: conventional
conventional handle
|
Wat meet het onderzoek?
Primaire uitkomstmaten
Uitkomstmaat |
Maatregel Beschrijving |
Tijdsspanne |
|---|---|---|
|
Composite neonatal brain damage
Tijdsspanne: From start of extraction through 28 days after delivery (or until discharge from the hospital)
|
Composite consists of: Hypoxic ischemic encephalopathy (HIE), intracranial hemorrhage (ICH), seizures, perinatal mortality and subgaleal hematoma as routinely diagnosed in patient chart
|
From start of extraction through 28 days after delivery (or until discharge from the hospital)
|
Medewerkers en onderzoekers
Sponsor
Onderzoekers
- Hoofdonderzoeker: Magnus Westgren, Professor, Karolinska Institutet
Publicaties en nuttige links
Algemene publicaties
- MALMSTROM T. The vacuum extractor, an obstetrical instrument. I. Acta Obstet Gynecol Scand Suppl. 1957;36(suppl 3):5-50. No abstract available.
- Moolgaoker AS, Ahamed SO, Payne PR. A comparison of different methods of instrumental delivery based on electronic measurements of compression and traction. Obstet Gynecol. 1979 Sep;54(3):299-309.
- Towner DR, Ciotti MC. Operative vaginal delivery: a cause of birth injury or is it? Clin Obstet Gynecol. 2007 Sep;50(3):563-81. doi: 10.1097/GRF.0b013e31811eaa39.
- Whitby EH, Griffiths PD, Rutter S, Smith MF, Sprigg A, Ohadike P, Davies NP, Rigby AS, Paley MN. Frequency and natural history of subdural haemorrhages in babies and relation to obstetric factors. Lancet. 2004 Mar 13;363(9412):846-51. doi: 10.1016/S0140-6736(04)15730-9.
- Pettersson K, Ajne J, Yousaf K, Sturm D, Westgren M, Ajne G. Traction force during vacuum extraction: a prospective observational study. BJOG. 2015 Dec;122(13):1809-16. doi: 10.1111/1471-0528.13222. Epub 2015 Jan 5.
- Romero S, Pettersson K, Yousaf K, Westgren M, Ajne G. Perinatal outcome after vacuum assisted delivery with digital feedback on traction force; a randomised controlled study. BMC Pregnancy Childbirth. 2021 Feb 26;21(1):165. doi: 10.1186/s12884-021-03604-z.
Studie record data
Bestudeer belangrijke data
Studie start
Primaire voltooiing (Werkelijk)
Studie voltooiing (Werkelijk)
Studieregistratiedata
Eerst ingediend
Eerst ingediend dat voldeed aan de QC-criteria
Eerst geplaatst (Werkelijk)
Updates van studierecords
Laatste update geplaatst (Werkelijk)
Laatste update ingediend die voldeed aan QC-criteria
Laatst geverifieerd
Meer informatie
Termen gerelateerd aan deze studie
Aanvullende relevante MeSH-voorwaarden
- Pathologische processen
- Hart-en vaatziekten
- Vaatziekten
- Cerebrovasculaire aandoeningen
- Ziekten van het centrale zenuwstelsel
- Ziekten van het zenuwstelsel
- Neurologische manifestaties
- Bloeding
- Tekenen en symptomen, ademhaling
- Hypoxie
- Hypoxie, hersenen
- Ischemie van de hersenen
- Aanvallen
- Hersenziekten
- Hypoxie-Ischemie, Hersenen
- Hematoom
Andere studie-ID-nummers
- KI-Clintec-SVEA
Plan Individuele Deelnemersgegevens (IPD)
Bent u van plan om gegevens van individuele deelnemers (IPD) te delen?
Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .