- ICH GCP
- US Clinical Trials Registry
- Klinisk utprøving NCT03071783
Intra-operative Feed Back on Traction Force During Vacuum Extraction: Safe Vacuum Extraction Alliance (SVEA)
Intra-operative Feed Back on Traction Force During Vacuum Extraction: a Randomized Control Study of Mid and Low Metal Cup Deliveries.
The objective of the clinical investigation is to test whether intra-operative traction force feed back during vacuum extraction leads to a significant decrease in incidence of brain damage in neonates.
By randomization, half of the vacuum extraction patients will be assigned to delivery using a new intelligent handle for vacuum extractions, and half will be assigned to conventional method without traction force measurement.
Studieoversikt
Status
Intervensjon / Behandling
Detaljert beskrivelse
The most common indications for vacuum extraction are dystocia and/or fetal asphyxia. The safety of assisted vaginal delivery with vacuum extraction has been discussed since its introduction almost fifty years ago. Serious complications such as asphyxia, intracranial hemorrhage and seizures are overrepresented at vacuum extraction compared to spontaneous vaginal delivery.
Little has been done to improve the procedure since the introduction. Safety measures recommended include restricting total time and number of pulls, a full 34 week gestation, and station of the head at the spines or below. A general advice is also to avoid excessive traction force. There is no general agreement to what a safe traction force might be. With exceeding force there seems to be an increased risk for rupture of the sagittal sinus and tearing of the falx at its attachment to the tentorium. Furthermore, when the fetal head is becoming exceedingly elongated and flattened, and as the cup pops off it might cause damage to the brain and blood vessels.
During the procedure the obstetrician is under significant stress and the subjective element of the evaluation of traction force is a concern. The difficult decision of whether to continue a heavy extraction or abort the operation is made under stressful conditions and based mostly on subjective impressions.
To provide the obstetrician with more objective information, the investigators developed a new device consisting of an intelligent handle hooked to the chain of a regular metal cup.
Studietype
Registrering (Faktiske)
Fase
- Ikke aktuelt
Kontakter og plasseringer
Studiesteder
-
-
-
Stockholm, Sverige, 14186
- Karolinska University Hospital
-
-
Deltakelseskriterier
Kvalifikasjonskriterier
Alder som er kvalifisert for studier
- Barn
- Voksen
- Eldre voksen
Tar imot friske frivillige
Kjønn som er kvalifisert for studier
Beskrivelse
Inclusion Criteria:
- Medical or social reasons for vacuum extraction with a metal cup, gestational age ≥37+0 weeks, singleton, cephalic
Exclusion Criteria:
- Multiple pregnancy, breech presentation, gestational age <37+0
Studieplan
Hvordan er studiet utformet?
Designdetaljer
- Primært formål: Forebygging
- Tildeling: Randomisert
- Intervensjonsmodell: Parallell tildeling
- Masking: Enkelt
Våpen og intervensjoner
Deltakergruppe / Arm |
Intervensjon / Behandling |
---|---|
Eksperimentell: Vacuum extraction intelligent system
Measurement and intra-operative feed back of vacuum extraction data: notification signal based an algorithm calculation using traction force (peak and time force integral) and time.
|
Vacuum extraction intelligent system - this is the intervention
|
Ingen inngripen: conventional
conventional handle
|
Hva måler studien?
Primære resultatmål
Resultatmål |
Tiltaksbeskrivelse |
Tidsramme |
---|---|---|
Composite neonatal brain damage
Tidsramme: From start of extraction through 28 days after delivery (or until discharge from the hospital)
|
Composite consists of: Hypoxic ischemic encephalopathy (HIE), intracranial hemorrhage (ICH), seizures, perinatal mortality and subgaleal hematoma as routinely diagnosed in patient chart
|
From start of extraction through 28 days after delivery (or until discharge from the hospital)
|
Samarbeidspartnere og etterforskere
Sponsor
Etterforskere
- Hovedetterforsker: Magnus Westgren, Professor, Karolinska Institutet
Publikasjoner og nyttige lenker
Generelle publikasjoner
- MALMSTROM T. The vacuum extractor, an obstetrical instrument. I. Acta Obstet Gynecol Scand Suppl. 1957;36(suppl 3):5-50. No abstract available.
- Moolgaoker AS, Ahamed SO, Payne PR. A comparison of different methods of instrumental delivery based on electronic measurements of compression and traction. Obstet Gynecol. 1979 Sep;54(3):299-309.
- Towner DR, Ciotti MC. Operative vaginal delivery: a cause of birth injury or is it? Clin Obstet Gynecol. 2007 Sep;50(3):563-81. doi: 10.1097/GRF.0b013e31811eaa39.
- Whitby EH, Griffiths PD, Rutter S, Smith MF, Sprigg A, Ohadike P, Davies NP, Rigby AS, Paley MN. Frequency and natural history of subdural haemorrhages in babies and relation to obstetric factors. Lancet. 2004 Mar 13;363(9412):846-51. doi: 10.1016/S0140-6736(04)15730-9.
- Pettersson K, Ajne J, Yousaf K, Sturm D, Westgren M, Ajne G. Traction force during vacuum extraction: a prospective observational study. BJOG. 2015 Dec;122(13):1809-16. doi: 10.1111/1471-0528.13222. Epub 2015 Jan 5.
- Romero S, Pettersson K, Yousaf K, Westgren M, Ajne G. Perinatal outcome after vacuum assisted delivery with digital feedback on traction force; a randomised controlled study. BMC Pregnancy Childbirth. 2021 Feb 26;21(1):165. doi: 10.1186/s12884-021-03604-z.
Studierekorddatoer
Studer hoveddatoer
Studiestart
Primær fullføring (Faktiske)
Studiet fullført (Faktiske)
Datoer for studieregistrering
Først innsendt
Først innsendt som oppfylte QC-kriteriene
Først lagt ut (Faktiske)
Oppdateringer av studieposter
Sist oppdatering lagt ut (Faktiske)
Siste oppdatering sendt inn som oppfylte QC-kriteriene
Sist bekreftet
Mer informasjon
Begreper knyttet til denne studien
Ytterligere relevante MeSH-vilkår
- Patologiske prosesser
- Kardiovaskulære sykdommer
- Vaskulære sykdommer
- Cerebrovaskulære lidelser
- Sykdommer i sentralnervesystemet
- Sykdommer i nervesystemet
- Nevrologiske manifestasjoner
- Blødning
- Tegn og symptomer, luftveier
- Hypoksi
- Hypoksi, hjerne
- Hjerneiskemi
- Anfall
- Hjernesykdommer
- Hypoksi-iskemi, hjerne
- Hematom
Andre studie-ID-numre
- KI-Clintec-SVEA
Plan for individuelle deltakerdata (IPD)
Planlegger du å dele individuelle deltakerdata (IPD)?
Denne informasjonen ble hentet direkte fra nettstedet clinicaltrials.gov uten noen endringer. Hvis du har noen forespørsler om å endre, fjerne eller oppdatere studiedetaljene dine, vennligst kontakt register@clinicaltrials.gov. Så snart en endring er implementert på clinicaltrials.gov, vil denne også bli oppdatert automatisk på nettstedet vårt. .
Kliniske studier på Vacuum extraction intelligent system
-
University of TennesseeFullført
-
SOMAVAC Medical SolutionsUniversity of TennesseeUkjentHematom postoperativt | Seroma som prosedyrekomplikasjonForente stater
-
Sun Yat-sen UniversityUkjent
-
NovaSignal Corp.National Institute of Neurological Disorders and Stroke (NINDS); National...AvsluttetSlag | Akutt iskemisk hjerneslagForente stater
-
University College of Medical Sciences, IndiaNorwegian University of Science and Technology; Indraprastha Institute...FullførtAngst | Fobier | AkrofobiIndia
-
Sun Yat-sen UniversityRekrutteringØyesykdommer | NødsituasjonerKina
-
RenJi HospitalChanghai Hospital; Peking University People's Hospital; Shanghai Zhongshan... og andre samarbeidspartnereRekruttering
-
Sun Yat-sen UniversityFullførtKunstig intelligens | OftalmopatiKina
-
Abramson Cancer Center of the University of PennsylvaniaFullført
-
Shanghai Minimally Invasive Surgery CenterUkjent