Cette page a été traduite automatiquement et l'exactitude de la traduction n'est pas garantie. Veuillez vous référer au version anglaise pour un texte source.

Immediate Loading of Implants in the Aesthetic Zone Using Three-dimensionally Printed Provisional Crowns: a 1-year Prospective Case Series Study

1 juin 2026 mis à jour par: University Medical Center Groningen

• Background There is a growing tendency to place a provisional crown immediately following implant placement. Clinical advantages are shortening of treatment duration and soft tissue guiding during healing resulting in better aesthetic outcomes. It was shown that good esthetic results can be achieved on the long term with immediate provisionalization of single-tooth implants placed in either fresh extraction sockets or after alveolar ridge preservation/reconstruction in the maxillary esthetic zone.

One recent development in three-dimensional printing is digital press stereolithography (DPS), which overcomes the challenges of printing highly-filled viscous materials. This enables the use of more durable materials than traditional three-dimensionally printed provisional crowns and allows for rapid additive production of prosthetic restorations.

Until date, no studies have been described investigating immediate loading of implants in the aesthetic zone using three-dimensional DPS-printers and their impact on patient-satisfaction.

  • Main research question The purpose of this one-year prospective case series study is to perform an assessment of patient-reported outcomes of single-tooth implants with immediate provisionalization using three-dimensionally printed provisional crowns.
  • Design (including population, confounders/outcomes) The study design is a prospective, single-arm observational study for evaluation of 30 patients with a failing tooth in the maxillary aesthetic region to be treated with an implant-supported provisional and definitive restoration by means of a provisional and definitive crown. Outcomes: registration of time/complications during the diagnostic/planning/manufacturing process, evaluation of clinical and radiographical performance and aesthetic outcome.
  • Expected results Satisfying results for patients and professionals (VAS-scores and PES/WES-scores)

Aperçu de l'étude

Statut

Pas encore de recrutement

Description détaillée

• Introduction and rationale There is a growing tendency to place a provisional crown immediately following implant placement. Clinical advantages are shortening of treatment duration and soft tissue guiding during healing resulting in better aesthetic outcomes (El Ghoul & Chidiac, 2012). It was shown that good esthetic results can be achieved on the long term with immediate provisionalization of single-tooth implants placed in either fresh extraction sockets or after alveolar ridge preservation/reconstruction in the maxillary esthetic zone (Donker et al., 2024; Meijer et al., 2025).

The popularity of immediate implant loading is related to evolving society factors, including more demanding patients and a wish for direct treatment (Huynh-Ba et al., 2018). Developments in the digital workflow in implant dentistry made treatment planning with the use of intra-oral scans and cone-beam computed tomography (CBCT) and fabrication of a provisional restoration using three-dimensional printers for additive manufacturing possible, further shortening the treatment duration. It was shown that patients prefer intra-oral scanning over analog impression taking (Schepke et al., 2015). Thus, it can be assumed that a digital workflow has advantages over an analog workflow for both the clinician and patients. One recent development in three-dimensional printing is digital press stereolithography (DPS), which overcomes the challenges of printing highly-filled viscous materials. This enables the use of more durable materials than traditional provisional crowns and allows for rapid additive production of prosthetic restorations.

Until date, no studies have been described investigating immediate loading of implants in the aesthetic zone using three-dimensional DPS-printers and their impact on patient-satisfaction.

The purpose of this one-year prospective case series study is to perform an assessment of patient-reported outcomes of single-tooth implants with immediate provisionalization using three-dimensionally printed provisional crowns, with respect to registration of time/complications during the diagnostic/planning/manufacturing process, evaluation of clinical and radiographical performance and aesthetic outcome.

Type d'étude

Observationnel

Inscription (Estimé)

30

Contacts et emplacements

Cette section fournit les coordonnées de ceux qui mènent l'étude et des informations sur le lieu où cette étude est menée.

Coordonnées de l'étude

  • Nom: Henny J A Meijer, Professor doctor
  • Numéro de téléphone: +31503616161
  • E-mail: h.j.a.meijer@umcg.nl

Lieux d'étude

    • Provincie Groningen
      • Groningen, Provincie Groningen, Pays-Bas, 9700RB
        • University Medical Center Groningen
        • Chercheur principal:
          • Henny JA Meijer, Professor doctor
        • Contact:
          • Henny J A Meijer, Professor doctor
          • Numéro de téléphone: +31503616161
          • E-mail: h.j.a.meijer@umcg.nl

Critères de participation

Les chercheurs recherchent des personnes qui correspondent à une certaine description, appelée critères d'éligibilité. Certains exemples de ces critères sont l'état de santé général d'une personne ou des traitements antérieurs.

Critère d'éligibilité

Âges éligibles pour étudier

  • Adulte
  • Adulte plus âgé

Accepte les volontaires sains

Non

Méthode d'échantillonnage

Échantillon non probabiliste

Population étudiée

Patient is missing a tooth in the maxillary esthetic region and indicated to be treated with a dental implant and restoration

La description

Inclusion Criteria:

  • The patient is 18 years or older;
  • The implant region is an incisor (central or lateral), cuspid or first bicuspid in the maxilla; the adjacent teeth are natural teeth;
  • Sufficient healthy and vital bone after alveolar ridge preservation to insert a dental implant with a minimum length of 10 mm and at least 3.5 mm in diameter with initial stability > 45 Ncm;
  • The implant site must be free from infection;
  • Adequate oral hygiene (modified plaque index and modified sulcus bleeding index ≤ 1);
  • Sufficient mesio-distal, bucco-lingual, and interocclusal space for placement of an anatomic crown;
  • The provisional crown can be designed free from occlusal contact;
  • The patient is capable of understanding and giving informed consent.

Exclusion Criteria:

  • Medical and general contraindications for the surgical procedures;
  • Presence of an active and uncontrolled periodontal disease;
  • Bruxism;
  • Smoking
  • A history of local radiotherapy to the head and neck region.

Plan d'étude

Cette section fournit des détails sur le plan d'étude, y compris la façon dont l'étude est conçue et ce que l'étude mesure.

Comment l'étude est-elle conçue ?

Détails de conception

Cohortes et interventions

Groupe / Cohorte
Printed provisional restoration
Patients with implant placement in the maxillary esthetic region and with immediate placement of a printed provisional restoration.

Que mesure l'étude ?

Principaux critères de jugement

Mesure des résultats
Description de la mesure
Délai
Change in peri-implant marginal bone level Description: Comparison between peri-implant bone level at implant placement and follow-up time point in millimeters measured on intraoral radiographs Time Frame: Through study completion, an average of 1 year
Délai: Through study completion, an average of 1 year
Comparison between peri-implant bone level at implant placement and follow-up time point in millimeters measured on intraoral radiographs
Through study completion, an average of 1 year

Mesures de résultats secondaires

Mesure des résultats
Description de la mesure
Délai
Survie de l'implant et de la restauration
Délai: Jusqu'à la fin de l'étude, en moyenne 1 an
Pourcentage d'implants et de restaurations présents au moment du suivi
Jusqu'à la fin de l'étude, en moyenne 1 an
Satisfaction des patients
Délai: 1 an
Satisfaction du patient mesurée sur une échelle visuelle analogique. Minimum = 0 (extrêmement insatisfait) ; Maximum = 100 (extrêmement satisfait).
1 an
Score de plaque
Délai: 1 an
Indice de plaque de 0 à 3. Minimum = 0 (aucune plaque visible) ; Maximum = 3 (quantité abondante de plaque visible)
1 an
Score gingival
Délai: 1 an
Santé de la muqueuse péri-implantaire décrite par l'indice gingival de 0 à 3. Minimum = 0 (muqueuse saine) ; Maximum = 3 (muqueuse très infectée).
1 an
Profondeur de poche
Délai: 1 an
Profondeur de sondage dans le sillon péri-implantaire en millimètres mesurée avec une sonde parodontale.
1 an
Bleeding score
Délai: 1 year
Bleeding in peri-implant sulcus after probing measured with a Bleeding index from 0 to 3. Minimum = 0 (no bleeding after probing); Maximum = 3 (abundance amount of bleeding after probing).
1 year

Collaborateurs et enquêteurs

C'est ici que vous trouverez les personnes et les organisations impliquées dans cette étude.

Dates d'enregistrement des études

Ces dates suivent la progression des dossiers d'étude et des soumissions de résultats sommaires à ClinicalTrials.gov. Les dossiers d'étude et les résultats rapportés sont examinés par la Bibliothèque nationale de médecine (NLM) pour s'assurer qu'ils répondent à des normes de contrôle de qualité spécifiques avant d'être publiés sur le site Web public.

Dates principales de l'étude

Début de l'étude (Estimé)

1 juillet 2026

Achèvement primaire (Estimé)

1 juillet 2027

Achèvement de l'étude (Estimé)

1 juillet 2027

Dates d'inscription aux études

Première soumission

1 juin 2026

Première soumission répondant aux critères de contrôle qualité

1 juin 2026

Première publication (Réel)

5 juin 2026

Mises à jour des dossiers d'étude

Dernière mise à jour publiée (Réel)

5 juin 2026

Dernière mise à jour soumise répondant aux critères de contrôle qualité

1 juin 2026

Dernière vérification

1 mai 2026

Plus d'information

Termes liés à cette étude

Autres numéros d'identification d'étude

  • Printed provisional crowns

Plan pour les données individuelles des participants (IPD)

Prévoyez-vous de partager les données individuelles des participants (DPI) ?

NON

Informations sur les médicaments et les dispositifs, documents d'étude

Étudie un produit pharmaceutique réglementé par la FDA américaine

Non

Étudie un produit d'appareil réglementé par la FDA américaine

Non

Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .

S'abonner