Perfusion index as a predictor of hypotension following spinal anaesthesia in lower segment caesarean section

Devika Rani Duggappa, Mps Lokesh, Aanchal Dixit, Rinita Paul, R S Raghavendra Rao, P Prabha, Devika Rani Duggappa, Mps Lokesh, Aanchal Dixit, Rinita Paul, R S Raghavendra Rao, P Prabha

Abstract

Background and aims: Perfusion index (PI) is a new parameter tried for predicting hypotension during spinal anaesthesia for the lower segment caesarean section (LSCS). This study aimed at investigating the correlation between baseline perfusion index and incidence of hypotension following SAB in LSCS.

Methods: In this prospective observational study, 126 parturients were divided into two groups on the basis of baseline PI. Group I included parturients with PI of ≤3.5 and Group II, parturients with PI values >3.5. Spinal anaesthesia was performed with 10 mg of injection bupivacaine 0.5% (hyperbaric) at L3-L4 or L2-L3 interspace. Hypotension was defined as mean arterial pressure <65 mmHg. Statistical analysis was performed using Chi-square test, independent sample t-test and Mann-Whitney U-test. Regression analysis with Spearman's rank correlation coefficient was done to assess the correlation between baseline PI and hypotension. Receiver operating characteristic (ROC) curve was plotted for PI and occurrence of hypotension.

Results: The incidence of hypotension in Group I was 10.5% compared to 71.42% in Group II (P < 0.001). There was significant correlation between baseline PI >3.5 and number of episodes of hypotension (rs0.416, P < 0.001) and total dose of ephedrine (rs0.567, P < 0.001). The sensitivity and specificity of baseline PI of 3.5 to predict hypotension was 69.84% and 89.29%, respectively. The area under the ROC curve for PI to predict hypotension was 0.848.

Conclusion: Baseline perfusion index >3.5 is associated with a higher incidence of hypotension following spinal anesthesia in elective LSCS.

Keywords: Hypotension; perfusion index; pregnancy; spinal anaesthesia.

Conflict of interest statement

There are no conflicts of interest.

Figures

Figure 1
Figure 1
CONSORT Flow Diagram
Figure 2
Figure 2
Comparison of systolic blood pressure, diastolic blood pressure and mean arterial pressure between the two groups intraoperatively. Systolic, diastolic and mean arterial pressure values presented as mean ± standard deviation. Statistical analysis done using independent t-test P > 0.05
Figure 3
Figure 3
ROC curve depicting baseline PI against incidence of hypotension

References

    1. Hanss R, Bein B, Ledowski T, Lehmkuhl M, Ohnesorge H, Scherkl W, et al. Heart rate variability predicts severe hypotension after spinal anesthesia for elective cesarean delivery. Anesthesiology. 2005;102:1086–93.
    1. Gaiser R. Physiological changes of pregnancy. In: Chestnut DH, editor. Chestnut's Obstetric Anaesthesia: Principles and Practice. 5th ed. Philadelphia: Mosby Elsevier Publishing; 2014. pp. 15–38.
    1. Hales JR, Stephens FR, Fawcett AA, Daniel K, Sheahan J, Westerman RA, et al. Observations on a new non-invasive monitor of skin blood flow. Clin Exp Pharmacol Physiol. 1989;16:403–15.
    1. Mowafi HA, Ismail SA, Shafi MA, Al-Ghamdi AA. The efficacy of perfusion index as an indicator for intravascular injection of epinephrine-containing epidural test dose in propofol-anesthetized adults. Anesth Analg. 2009;108:549–53.
    1. Ginosar Y, Weiniger CF, Meroz Y, Kurz V, Bdolah-Abram T, Babchenko A, et al. Pulse oximeter perfusion index as an early indicator of sympathectomy after epidural anesthesia. Acta Anaesthesiol Scand. 2009;53:1018–26.
    1. Lima AP, Beelen P, Bakker J. Use of a peripheral perfusion index derived from the pulse oximetry signal as a noninvasive indicator of perfusion. Crit Care Med. 2002;30:1210–3.
    1. Toyama S, Kakumoto M, Morioka M, Matsuoka K, Omatsu H, Tagaito Y, et al. Perfusion index derived from a pulse oximeter can predict the incidence of hypotension during spinal anaesthesia for caesarean delivery. Br J Anaesth. 2013;111:235–41.
    1. Park GE, Hauch MA, Curlin F, Datta S, Bader AM. The effects of varying volumes of crystalloid administration before cesarean delivery on maternal hemodynamics and colloid osmotic pressure. Anesth Analg. 1996;83:299–303.
    1. Ajne G, Ahlborg G, Wolff K, Nisell H. Contribution of endogenous endothelin-1 to basal vascular tone during normal pregnancy and preeclampsia. Am J Obstet Gynecol. 2005;193:234–40.
    1. Barwin BN, Roddie IC. Venous distensibility during pregnancy determined by graded venous congestion. Am J Obstet Gynecol. 1976;125:921–3.
    1. Sakai K, Imaizumi T, Maeda H, Nagata H, Tsukimori K, Takeshita A, et al. Venous distensibility during pregnancy. Comparisons between normal pregnancy and preeclampsia. Hypertension. 1994;24:461–6.
    1. Bowyer L, Brown MA, Jones M. Forearm blood flow in pre-eclampsia. BJOG. 2003;110:383–91.
    1. Clapp JF, 3rd, Capeless E. Cardiovascular function before, during, and after the first and subsequent pregnancies. Am J Cardiol. 1997;80:1469–73.
    1. Yokose M, Mihara T, Sugawara Y, Goto T. The predictive ability of non-invasive haemodynamic parameters for hypotension during caesarean section: A prospective observational study. Anaesthesia. 2015;70:555–62.

Source: PubMed

3
S'abonner