Skin antisepsis with chlorhexidine-alcohol versus povidone iodine-alcohol, combined or not with use of a bundle of new devices, for prevention of short-term peripheral venous catheter-related infectious complications and catheter failure: an open-label, single-centre, randomised, four-parallel group, two-by-two factorial trial: CLEAN 3 protocol study

Jérémy Guenezan, Bertrand Drugeon, Rodérick O'Neill, Diane Caillaud, Clément Sénamaud, Catherine Pouzet, Sabrina Seguin, Denis Frasca, Olivier Mimoz, Jérémy Guenezan, Bertrand Drugeon, Rodérick O'Neill, Diane Caillaud, Clément Sénamaud, Catherine Pouzet, Sabrina Seguin, Denis Frasca, Olivier Mimoz

Abstract

Introduction: Short peripheral intravenous catheters (PVCs) are the most frequently used invasive medical devices in hospitals. Unfortunately, PVCs often fail before the end of treatment due to the occurrence of mechanical, vascular or infectious complications, which prolongs hospitalisation and increases healthcare costs and mortality.Prevention of these complications is mainly based on the respect of hygiene rules and the use of biocompatible catheters. In critically ill patients, 2% chlorhexidine-alcohol is superior to 5% povidone iodine-alcohol for skin preparation before central venous and arterial catheters; whether this finding can be extended to PVC inserted in the wards remains speculative. Similarly, the use of new technologies such as catheters designed to minimise blood exposure, zero-reflux needleless connectors, disinfecting caps and flushing PVCs before and after each medication administration to maintain catheter patency are of theoretical interest to prevent PVC failure, but little scientific data support their routine use.

Methods and analysis: The CLEAN 3 study is an open-label, single-centre, randomised, two-by-two factorial trial. One thousand patients visiting our emergency department and requiring hospital admission in the wards will be randomised to one of four strategies according to skin preparation and devices used. The two primary endpoints will be (1) the incidence of infectious complications related to the catheters (colonisation, local infection or bloodstream infection) and (2) the time between catheter insertion and catheter failure defined as any premature removal of PVC before end of treatment, other than for routine replacement.

Ethics and dissemination: This protocol has been approved by an independent ethics committee and will be carried out according to the principles of the Declaration of Helsinki and the Good Clinical Practice guidelines. The results of this study will be disseminated through presentation at scientific conferences and publication in peer-reviewed journals.

Trial registration number: EudraCT 2018-A02535-50; NCT03757143.

Keywords: antiseptics; healthcare-associated infection; medical devices; prevention.

Conflict of interest statement

Competing interests: OM received grant support and honoraria for giving lectures from Becton Dickinson.

© Author(s) (or their employer(s)) 2019. Re-use permitted under CC BY-NC. No commercial re-use. See rights and permissions. Published by BMJ.

Figures

Figure 1
Figure 1
Study flowchart. CHG, chlorhexidine; IPA, isopropanol; PVC, peripheral intravenous catheters; PVI, povidone iodine.

References

    1. Keogh S, Flynn J, Marsh N, et al. . Varied flushing frequency and volume to prevent peripheral intravenous catheter failure: a pilot, factorial randomised controlled trial in adult medical-surgical hospital patients. Trials 2016;17:348 10.1186/s13063-016-1470-6
    1. Hadaway L. Short peripheral intravenous catheters and infections. J Infus Nurs 2012;35:230–40. 10.1097/NAN.0b013e31825af099
    1. Maki DG, Kluger DM, Crnich CJ. The risk of bloodstream infection in adults with different intravascular devices: a systematic review of 200 published prospective studies. Mayo Clin Proc 2006;81:1159–71. 10.4065/81.9.1159
    1. Mermel LA. Short-term peripheral venous catheter-related bloodstream infections: a systematic review. Clin Infect Dis 2017;65:1757–62. 10.1093/cid/cix562
    1. Tuffaha HW, Rickard CM, Webster J, et al. . Cost-effectiveness analysis of clinically indicated versus routine replacement of peripheral intravenous catheters. Appl Health Econ Health Policy 2014;12:51–8. 10.1007/s40258-013-0077-2
    1. Maki DG. Risk Factors for Infusion-related Phlebitis with small peripheral venous catheters. Ann Intern Med 1991;114:845–54. 10.7326/0003-4819-114-10-845
    1. Mimoz O, Lucet J-C, Kerforne T, et al. . Skin antisepsis with chlorhexidine–alcohol versus povidone iodine–alcohol, with and without skin scrubbing, for prevention of intravascular-catheter-related infection (CLEAN): an open-label, multicentre, randomised, controlled, two-by-two factorial trial. The Lancet 2015;386:2069–77. 10.1016/S0140-6736(15)00244-5
    1. Mimoz O, Chopra V, Timsit JF. What’s new in catheter-related infection: skin cleansing and skin antisepsis. Intensive Care Med 2016;42:1784–6. 10.1007/s00134-016-4244-4
    1. Mimoz O, Chopra V, Widmer A. What’s new in skin antisepsis for short-term intravascular catheters: new data to address old problems? Intensive Care Med 2016;42:2043–5. 10.1007/s00134-016-4490-5
    1. Frasca D, Dahyot-Fizelier C, Mimoz O. Prevention of central venous catheter-related infection in the intensive care unit. Crit Care 2010;14:212 10.1186/cc8853
    1. Timsit JF, Rupp M, Bouza E, et al. . A state of the art review on optimal practices to prevent, recognize, and manage complications associated with intravascular devices in the critically ill. Intensive Care Med 2018;44:742–59. 10.1007/s00134-018-5212-y
    1. Tabak YP, Jarvis WR, Sun X, et al. . Meta-analysis on central line-associated bloodstream infections associated with a needleless intravenous connector with a new engineering design. Am J Infect Control 2014;42:1278–84. 10.1016/j.ajic.2014.08.018
    1. Clavier T, Ferguen M, Gouin P, et al. . needle-free connector on the incidence of central venous catheter-related infections in surgical intensive care unit. Aust Crit Care 2018. (Published Apr 2018). 10.1016/j.aucc.2018.03.003
    1. Société Française d’Hygiène Hospitalière. Antisepsie de la peau saine avant un geste invasif chez l’adulte : recommandations pour la pratique clinique.. 2016. .
    1. Brun-Buisson C, Abrouk F, Legrand P, et al. . Diagnosis of central venous catheter-related sepsis. Critical level of quantitative tip cultures. Arch Intern Med 1987;147:873–7.
    1. McAlister FA, Straus SE, Sackett DL, et al. . Analysis and reporting of factorial trials: a systematic review. JAMA 2003;289:2545–53. 10.1001/jama.289.19.2545
    1. Schulz KF, Altman DG, Moher D, et al. . CONSORT 2010 statement: updated guidelines for reporting parallel group randomised trials. BMJ 2010;340:c332 10.1136/bmj.c332
    1. Mimoz O, Villeminey S, Ragot S, et al. . Chlorhexidine-based antiseptic solution vs alcohol-based povidone-iodine for central venous catheter care. Arch Intern Med 2007;167:2066 10.1001/archinte.167.19.2066
    1. Rijnders BJ, Van Wijngaerden E, Peetermans WE. Catheter-tip colonization as a surrogate end point in clinical studies on catheter-related bloodstream infection: how strong is the evidence? Clin Infect Dis 2002;35:1053–8. 10.1086/342905

Source: PubMed

3
S'abonner