Intra- and inter-rater reliability of isometric shoulder extensor and internal rotator strength measurements performed using a hand-held dynamometer

Takenori Awatani, Ikuhiro Morikita, Junji Shinohara, Seigo Mori, Miki Nariai, Yasutaka Tatsumi, Akinori Nagata, Hiroya Koshiba, Takenori Awatani, Ikuhiro Morikita, Junji Shinohara, Seigo Mori, Miki Nariai, Yasutaka Tatsumi, Akinori Nagata, Hiroya Koshiba

Abstract

[Purpose] The purpose of the present study was to establish the intra- and inter-rater reliability of measurement of extensor strength in the maximum shoulder abducted position and internal rotator strength in the 90° abducted and the 90° external rotated position using a hand-held dynamometer. [Subjects and Methods] Twelve healthy volunteers (12 male; mean ± SD: age 19.0 ± 1.1 years) participated in the study. The examiners were two students who had nonclinical experience with a hand-held dynamometer measurement. The examiners and participants were blinded to measurement results by the recorder. Participants in the prone position were instructed to hold the contraction against the ground reaction force, and peak isometric force was recorded using the hand-held dynamometer on the floor. Reliability was determined using intraclass correlation coefficients. [Results] The intra- and inter-rater reliability data were found to be "almost perfect". [Conclusion] This study investigated intra- and inter-rater reliability and reveald high reliability. Thus, the measurement method used in the present study can evaluate muscle strength by a simple measurement technique.

Keywords: Measurement error; Prone; Shoulder abduction.

References

    1. Gola R, Urbanik C, Iwańska D, et al. : Relationship between muscle strength and front crawl swimming velocity. Hum Mov, 2014, 15: 110–115.
    1. Haycraft J, Robertson S: The effects of concurrent aerobic training and maximal strength, power and swim-specific dry-land training methods on swim performance: a review. J Aust Strength Cond, 2015, 23: 91–99.
    1. Awatani T, Mori S, Shinohara J, et al. : Same-session and between-day intra-rater reliability of hand-held dynamometer measurements of isometric shoulder extensor strength. J Phys Ther Sci, 2016, 28: 936–939.
    1. Schrama PP, Stenneberg MS, Lucas C, et al. : Intraexaminer reliability of hand-held dynamometry in the upper extremity: a systematic review. Arch Phys Med Rehabil, 2014, 95: 2444–2469.
    1. Landis JR, Koch GG: The measurement of observer agreement for categorical data. Biometrics, 1977, 33: 159–174.
    1. Bland JM, Altman DG: Statistical methods for assessing agreement between two methods of clinical measurement. Lancet, 1986, 1: 307–310.
    1. Ludbrook J: Statistical techniques for comparing measurers and methods of measurement: a critical review. Clin Exp Pharmacol Physiol, 2002, 29: 527–536.
    1. Bohannon RW, Bubela DJ, Magasi SR, et al. : Relative reliability of three objective tests of limb muscle strength. Isokinet Exerc Sci, 2011, 19: 77–81.
    1. Atkinson G, Nevill AM: Statistical methods for assessing measurement error (reliability) in variables relevant to sports medicine. Sports Med, 1998, 26: 217–238.
    1. Cools AM, De Wilde L, Van Tongel A, et al. : Measuring shoulder external and internal rotation strength and range of motion: comprehensive intra-rater and inter-rater reliability study of several testing protocols. J Shoulder Elbow Surg, 2014, 23: 1454–1461.
    1. Katoh M: Test-retest reliability of isometric shoulder muscle strength measurement with a handheld dynamometer and belt. J Phys Ther Sci, 2015, 27: 1719–1722.
    1. Bohannon RW: Reference values for extremity muscle strength obtained by hand-held dynamometry from adults aged 20 to 79 years. Arch Phys Med Rehabil, 1997, 78: 26–32.
    1. van den Beld WA, van der Sanden GA, Sengers RC, et al. : Validity and reproducibility of hand-held dynamometry in children aged 4–11 years. J Rehabil Med, 2006, 38: 57–64.
    1. Riemann BL, Davies GJ, Ludwig L, et al. : Hand-held dynamometer testing of the internal and external rotator musculature based on selected positions to establish normative data and unilateral ratios. J Shoulder Elbow Surg, 2010, 19: 1175–1183.
    1. Kolber M, Cleland J: Strength testing using hand-held dynamometry. Phys Ther Rev, 2007, 10: 99–112.
    1. Wikholm JB, Bohannon RW: Hand-held dynamometer: tester strength makes a difference. J Orthop Sports Phys Ther, 1991, 13: 191–198.
    1. Stone CA, Nolan B, Lawlor PG, et al. : Hand-held dynamometry: tester strength is paramount, even in frail populations. J Rehabil Med, 2011, 43: 808–811.

Source: PubMed

3
S'abonner