Carbon dioxide insufflation in routine colonoscopy is safe and more comfortable: results of a randomized controlled double-blinded trial

M Geyer, U Guller, C Beglinger, M Geyer, U Guller, C Beglinger

Abstract

Many patients experience pain and discomfort after colonoscopy. Carbon dioxide (CO(2)) can reduce periprocedural pain although air insufflation remained the standard procedure. The objective of this double-blinded, randomized controlled trial was to evaluate whether CO(2) insufflation does decrease pain and bloating during and after colonoscopy compared to room air. Methods. 219 consecutive patients undergoing colonoscopy were randomized to either CO(2) or air insufflation. Propofol was used in all patients for sedation. Transcutaneous CO(2) was continuously measured with a capnograph as a safety parameter. Pain, bloating, and overall satisfaction were assessed at regular intervals before and after the procedure. Results(data are mean ±SD). 110 patients were randomized to CO(2) and 109 to room air. The baseline characteristics were similar in both groups. The mean propofol dose was not different between the treatments, as were the time to reach the ileum and the withdrawal time. pCO(2) at the end of the procedure was 35.2 ± 4.3 mmHg (CO(2) group) versus 35.6 ± 6.0 mmHg in the room air group (P > .05). No relevant complication occurred in either group. There was significantly less bloating for the CO(2) group during the postprocedural recovery period (P < .001) and over the 24-hour period (P < .001). Also, patients with CO(2) insufflation experienced significantly less pain (P = .014). Finally, a higher overall satisfaction (P = .04 ) was found in the CO(2) group. Conclusions. This trial provides compelling evidence that CO(2) insufflation significantly reduces bloating and pain after routine colonoscopy in propofol-sedated patients. The procedure is safe with no significant differences in CO(2) between the two groups.

Figures

Figure 1
Figure 1
Bloating over time depicted as visual analogue scale scores.
Figure 2
Figure 2
Pain over time depicted as visual analogue scale scores.
Figure 3
Figure 3
Transcutaneously measured CO2 values in CO2 and room air group.

References

    1. Janssens F, Deviere J, Eisendrath P, Dumonceau JM. Carbon dioxide for gut distension during digestive endoscopy: technique and practice survey. World Journal of Gastroenterology. 2009;15(12):1475–1479.
    1. Becker GL. prevention of gas explosions in the large bowel during electrosurgery. Surgery, Gynecology &amp; Obstetrics. 1953;97(4):463–467.
    1. Grant DS, Bartram CI. A preliminary study of the possible benefits of using carbon dioxide insufflation during double-contrast barium enema. British Journal of Radiology. 1986;59(698):190–191.
    1. Hussein AMJ. Carbon dioxide insufflation for more comfortable colonoscopy. Gastrointestinal Endoscopy. 1984;30(2):68–70.
    1. Coblentz CL, Frost RA, Molinaro V. Pain after barium enema: effect of CO2 and air on double-contrast study. Radiology. 1985;157(1):35–36.
    1. Sumanac K, Zealley I, Fox BM. Minimizing postcolonoscopy abdominal pain by using CO2 insufflation: a prospective, randomized, double blind, controlled trial evaluating a new commercially available CO2 delivery system. Gastrointestinal Endoscopy. 2002;56(2):190–194.
    1. Bretthauer M, Thiis-Evensen E, Huppertz-Hauss G. NORCCAP (Norwegian colorectal cancer prevention): a randomised trial to assess the safety and efficacy of carbon dioxide versus air insufflation in colonoscopy. Gut. 2002;50(5):604–607.
    1. Church J, Delaney C. Randomized, controlled trial of carbon dioxide insufflation during colonoscopy. Diseases of the Colon and Rectum. 2003;46(3):322–326.
    1. Riss S, Akan B, Mikola B, et al. CO2 insufflation during colonoscopy decreases post-interventional pain in deeply sedated patients: a randomized controlled trial. Wiener Klinische Wochenschrift. 2009;121(13–14):464–468.
    1. Yamano HO, Yoshikawa K, Kimura T, et al. Carbon dioxide insufflation for colonoscopy: evaluation of gas volume, abdominal pain, examination time and transcutaneous partial CO2 pressure. Journal of Gastroenterology. 2010;45(12):1235–1240.
    1. Dellon ES, Hawk JS, Grimm IS, Shaheen NJ. The use of carbon dioxide for insufflation during GI endoscopy: a systematic review. Gastrointestinal Endoscopy. 2009;69(4):843–849.
    1. Hoff G, Bretthauer M, Huppertz-Hauss G, et al. The Norwegian Gatronet project: continous quality improvement of colonoscopy in 14 Norwegian centers. Scandinavian Journal of Gastroenterology. 2006;41(4):481–487.
    1. Ko CW, Riffle S, Shapiro JA, et al. Incidence of minor complications and time lost from normal activities after screening or surveillance colonoscopy. Gastrointestinal Endoscopy. 2007;65(4):648–656.
    1. Heuss LT, Schnieper P, Drewe J, Pflimlin E, Beglinger C. Risk stratification and safe administration of propofol by registered nurses supervised by the gastroenterologist: a prospective observational study of more than 2000 cases. Gastrointestinal Endoscopy. 2003;57(6):664–671.
    1. Wong JCH, Yau KK, Wong DCT, Chung CC, Li MKW. Towards painless colonoscopy: a randomized controlled trial on carbon dioxide-insufflating colonoscopy. Australian and New Zealand Journal of Surgery. 2008;78(10):871–874.
    1. Stevenson GW, Wilson JA, Wilkinson J, Norman G, Goodacre RL. Pain following colonoscopy: elimination with carbon dioxide. Gastrointestinal Endoscopy. 1992;38(5):564–567.
    1. Bretthauer M, Seip B, Aasen S. Carbon dioxide insufflation for more comfortable ERCP: a randomized, controlled, double-blind trial. Endoscopy. 2007;39(1):58–64.
    1. Saito Y, Uraoka T, Matsuda T, et al. A pilot study to assess the safety and efficacy of carbon dioxide insufflation during colorectal endoscopic submucosal dissection with the patient under conscious sedation. Gastrointestinal Endoscopy. 2007;65(3):537–542.
    1. Domagk D, Bretthauer M, Lenz P. Carbon dioxide insufflation improves intubation depth in double-balloon enteroscopy: a randomized, controlled, double-blind trial. Endoscopy. 2007;39(12):1064–1067.
    1. Bretthauer M, Thiis-Evensen E, Hoff G. A randomized controlled trial to assess the safety and efficacy of carbon dioxide insufflation in colonoscopy. Gut. 2002;50(5):604–607.
    1. Bretthauer M, Lynge AB, Thiis-Evensen E, Hoff G. Carbon dioxide insufflation in colonoscopy: safe and effective in sedated patients. Endoscopy. 2005;37(8):706–709.
    1. Cullingford GL, Coffey JF, Carr-Locke DL. Irritable bowel syndrome: can the patient’s response to colonoscopy help with diagnosis? Digestion. 1992;52(3–4):209–213.
    1. Petrini JL, Egan JV, Hahn WV. Unsedated colonoscopy: patient characteristics and satisfaction in a community-based endoscopy unit. Gastrointestinal Endoscopy. 2009;69(3):567–572.

Source: PubMed

3
S'abonner