Study of Glove Perforation during Hip Replacement Arthroplasty: Its Frequency, Location, and Timing

Li Xiao Tao, Deepak Kumar Basnet, Li Xiao Tao, Deepak Kumar Basnet

Abstract

Objective. The aim of the study was to evaluate the location, timing, and frequency of glove perforation during hip replacement arthroplasty. Methods. Gloves worn by surgical team members in 19 primary hip replacement arthroplasties were assessed. The study was of a single gloving system. All the used gloves were collected at the end of the surgery and assessed visually and by using water inflation technique. Relevant data were collected at the time of surgery. Results. A total of one hundred and ninety-one surgical gloves were evaluated. Twenty-three glove perforations were noted in nineteen of the operations. Of these perforations 14 belonged to gloves worn by surgeon and first assistant (60.1%). Glove perforation in thumb, index finger, and palm was more common. More perforation occurred in the gloves worn in nondominant hand (52%) but was insignificant. Conclusion. Glove perforation in surgeries such as total hip arthroplasty is not uncommon. In this study of single gloving system glove perforation rate was 12.04%, whereas literature reports of glove perforation rate as low as 3.3% in elective orthopedic surgeries with double gloving system. As such emphasis should be given to wear double pair of gloves wherever this practice is uncommon.

Figures

Figure 1
Figure 1
Histogram showing glove perforation by region of hand.
Figure 2
Figure 2
Pie chart illustrating percentage of glove perforation in different part of glove.

References

    1. Tanner J., Parkinson H. Double gloving to reduce surgical cross-infection. Cochrane Database of Systematic Reviews. 2006;3CD003087
    1. Rabussay D. P., Korniewicz D. M. Improving glove barrier effectiveness. AORN journal. 1997;66(6):1043–1060. doi: 10.1016/S0001-2092(06)62544-1.
    1. Charnley J. A Sterile-Air Operating Theatre Enclosure. The British Journal of Surgery. 1964;51:195–202. doi: 10.1002/bjs.1800510308.
    1. Hughes S. P. F., Anderson F. M. Infection in the operating room. Journal of Bone and Joint Surgery B. 1999;81(5):754–755. doi: 10.1302/0301-620X.81B5.10370.
    1. Lidwell O. M., Elson R. A., Lowbury E. J. L., et al. Ultraclean air and antibiotics for prevention of postoperative infection. A multicenter study of 8,052 joint replacement operations. Acta Orthopaedica Scandinavica. 1987;58(1):4–13. doi: 10.3109/17453678709146334.
    1. Fitzgerald R. H., Jr., Bechtol C. O., Eftekhar N., Nelson J. P. Reduction of deep sepsis after total hip arthroplasty. Archives of Surgery. 1979;114(7):803–804. doi: 10.1001/archsurg.1979.01370310045009.
    1. Laine T., Aarnio P. Glove perforation in orthopaedic and trauma surgery. A comparison between single, double indicator gloving and double gloving with two regular gloves. Journal of Bone and Joint Surgery B. 2004;86(6):898–900. doi: 10.1302/0301-620X.86B6.14821.
    1. Brough S. J., Hunt T. M., Barrie W. W. Surgical glove perforations. The British Journal of Surgery. 1988;75(4):p. 317. doi: 10.1002/bjs.1800750408.
    1. Berridge D. C., Galea M. H., Evans D. F., Pugh S., Hopkinson B. R., Makin G. S. Hepatitis B immunization in vascular surgeons. British Journal of Surgery. 1990;77(5):585–586. doi: 10.1002/bjs.1800770540.
    1. Brignall C. G. M. C. G. Hepatitis B vaccination: a survey of orthopaedic surgeons. Journal of Bone and Joint Surgery. British. 1991;73(supplement 1):89–90.
    1. Panlilio A. L., Foy D. R., Edwards J. R., et al. Blood contacts during surgical procedures. Journal of the American Medical Association. 1991;265(12):1533–1537. doi: 10.1001/jama.265.12.1533.
    1. Gerberding J. L., Littell C., Tarkington A., Brown A., Schecter W. P. Risk of exposure of surgical personnel to patients' blood during surgery at San Francisco General Hospital. The New England Journal of Medicine. 1990;322(25):1788–1793. doi: 10.1056/NEJM199006213222506.
    1. Matta H., Thompson A. M., Rainey J. B. Does wearing two pairs of gloves protect operating theatre staff from skin contamination? British Medical Journal. 1988;297(6648):597–598. doi: 10.1136/bmj.297.6648.597.
    1. Green S. E., Gompertz R. H. K. Glove perforation during surgery: what are the risks? Annals of the Royal College of Surgeons of England. 1992;74(5):306–308.
    1. Eckersley J. R. T., Williamson D. M. Glove punctures in an orthopaedic trauma unit. Injury. 1990;21(3):177–178. doi: 10.1016/0020-1383(90)90090-H.
    1. McLeod G. G. Needlestick injuries at operations for trauma. Are surgical gloves an effective barrier? Journal of Bone and Joint Surgery Series B. 1989;71(3):489–491.
    1. McCue S. F., Berg E. W., Saunders E. A. Efficacy of double-gloving as a barrier to microbial contamination during total joint arthroplasty. The Journal of Bone & Joint Surgery A. 1981;63(5):811–813.
    1. Palmer J. D., Rickett J. W. S. The mechanisms and risks of surgical glove perforation. Journal of Hospital Infection. 1992;22(4):279–286. doi: 10.1016/0195-6701(92)90013-C.
    1. Al-Maiyah M., Bajwa A., Finn P., et al. Glove perforation and contamination in primary total hip arthroplasty. Journal of Bone and Joint Surgery B. 2005;87(4):556–559. doi: 10.1302/0301-620X.87B4.15744.
    1. Hübner N.-O., Goerdt A.-M., Stanislawski N., et al. Bacterial migration through punctured surgical gloves under real surgical conditions. BMC Infectious Diseases. 2010;10, article 192 doi: 10.1186/1471-2334-10-192.
    1. European Communities. Commission communication in the framework of the implementation of council directive 93/42/EEC of 14 June 1993 in relation to medical devices and directive 98/79/EC of the European Parliament and of the Council of 27 October 1998 on in-vitro diagnostic medical devices. Official Journal of the European Union. 2001;44(C319/13)
    1. Maffulli N., Capasso G., Testa V. Glove perforation in elective orthopedic surgery. Acta Orthopaedica Scandinavica. 1989;60(5):565–566. doi: 10.3109/17453678909150123.
    1. Yinusa W., Li Y. H., Chow W., Ho W. Y., Leong J. C. Y. Glove punctures in orthopaedic surgery. International Orthopaedics. 2004;28(1):36–39. doi: 10.1007/s00264-003-0510-5.
    1. Dodds R. D. A., Guy P. J., Peacock A. M., Duffy S. R., Barker S. G. E., Thomas M. H. Surgical glove perforation. The British Journal of Surgery. 1988;75(10):966–968. doi: 10.1002/bjs.1800751009.
    1. Harnoss J.-C., Partecke L.-I., Heidecke C.-D., Hübner N.-O., Kramer A., Assadian O. Concentration of bacteria passing through puncture holes in surgical gloves. American Journal of Infection Control. 2010;38(2):154–158. doi: 10.1016/j.ajic.2009.06.013.
    1. Brown A. R., Taylor G. J. S., Gregg P. J. Air contamination during skin preparation and draping in joint replacement surgery. Journal of Bone and Joint Surgery—Series B. 1996;78(1):92–94.
    1. Jamal A., Wilkinson S. The mechanical and microbiological integrity of surgical gloves. ANZ Journal of Surgery. 2003;73(3):140–143. doi: 10.1046/j.1445-2197.2003.02645.x.
    1. Misteli H., Weber W. P., Reck S., et al. Surgical glove perforation and the risk of surgical site infection. Archives of Surgery. 2009;144(6):553–558. doi: 10.1001/archsurg.2009.60.
    1. Demircay E., Unay K., Bilgili M. G., Alataca G. Glove perforation in hip and knee arthroplasty. Journal of Orthopaedic Science. 2010;15(6):790–794. doi: 10.1007/s00776-010-1547-0.

Source: PubMed

3
S'abonner