Clinical pain evaluation with intraoral vibration device during local anesthetic injections

Amin Nasehi, Savita Bhardwaj, Abhay-Taranath Kamath, Srikanth Gadicherla, Kalyana-Chakravarty Pentapati, Amin Nasehi, Savita Bhardwaj, Abhay-Taranath Kamath, Srikanth Gadicherla, Kalyana-Chakravarty Pentapati

Abstract

Objectives: To evaluate the clinical pain during local anesthetic injection using such intra-oral device.

Study design: A comparative split-mouth clinical study to evaluate clinical pain was conducted among the subjects who required bilateral local anesthetic intra-oral injections.

Results: A total of 99 subjects participated in the study out of which 39 were female. A total of 256 local anesthetic injections were administered to all the subjects with at least one pair of similar local anesthetic injections. Comparison of mean VAS score for anticipated pain in without vibration group was significantly higher in all types of nerve blocks when compared to that of with vibration. Similarly, the comparison of mean VAS score for actual pain in without vibration group was significantly higher in all types of nerve blocks when compared to that of with vibration. No significant difference in the mean VAS score was seen between anticipated and actual pain in without vibration group with respect to inferior alveolar (p=0.673), infra-orbital (p=0.175) and palatal (p=0.343) local anesthetic injections. The mean VAS score was significantly lower for actual pain when compared to anticipated pain in vibration group with respect to inferior alveolar (p<0.001) and infra-orbital (p=0.002) local anesthetic injections.

Conclusions: There was significant reduction in the pain encountered during local anesthetic injection with the use of intra-oral vibration device. Key words:Pain, vibration, visual analogue scale, local anesthesia.

Figures

Figure 1
Figure 1
Vibration device (DentalVibe) used in the study.
Figure 2
Figure 2
Intra-oral placement of vibration device (DentalVibe).

References

    1. International Association for the Study of Pain. Sub-committee on taxonomy. Pain terms: a list with definitions and notes on usage. Pain. 1979;6:249–252.
    1. Locker D, Grushka M. Prevalence of oral and facial pain and discomfort: preliminary results of a mail survey. Community Dent Oral Epidemiol. 1987;15:169–172.
    1. Chen BK, Eichenfield LF. Pediatric anesthesia in dermatologic surgery: when hand-holding is not enough. Dermatol Surg. 2001;27:1010–8.
    1. Brogan GX Jr, Giarrusso E, Hollander JE, Cassara G, Maranga MC, Thode HC. Comparison of plain, warmed, and buffered lidocaine for anesthesia of traumatic wounds. Ann Emerg Med. 1995;26:121–5.
    1. Maloney JM, Bezzant JL, Stephen RL, Petelenz TJ. Iontophoretic administration of lidocaine anesthesia in office practice. An appraisal. J Dermatol Surg Oncol. 1992;18:937–40.
    1. Swinehart JM. The ice-saline-Xylocaine technique. A simple method for minimizing pain in obtaining local anesthesia. J Dermatol Surg Oncol. 1992;18:28–30.
    1. Watanabe T, Koshiba K, Okuda H. Comparison of the pain perception induced by intra oral penetration by a new fine needle and a 30-gauge needle. J Jpn Dent Soc Anesthesiol. 1995;23:19–30.
    1. Smith KC, Comite SL, Balasubramanian S, Carver A, Liu JF. Vibration anesthesia: a noninvasive method of reducing discomfort prior to dermatologic procedures. Dermatol Online J. 2004;15:10–1.
    1. Nanitsos E, Vartuli R, Forte A, Dennison PJ, Peck CC. The effect of vibration on pain during local anaesthesia injections. Aust Dent J. 2009;54:94–100.
    1. Melzack R, Wall PD. Pain mechanisms: a new theory. Science. 1965;150:971–9.
    1. Dickenson AH. Gate control theory of pain stands the test of time. Br J Anaesth. 2002;88:755–7.
    1. Hutchins HS Jr, Young FA, Lackland DT, Fishburne CP. The effectiveness of topical anesthesia and vibration in alleviating the pain of oral injections. Anesth Prog. 1997;44:87–9.
    1. Saijo M, Ito E, Ichinohe T, Kaneko Y. Lack of pain reduction by a vibrating local anesthetic attachment: a pilot study. Anesth Prog. 2005;52:62–4.
    1. Bonjar S. Syringe micro vibrator (SMV) a new device being introduced in dentistry to alleviate pain and anxiety of intraoral injections, and a comparative study with a similar device. Ann Surgical Innovation Res. 2011;5:1.

Source: PubMed

3
S'abonner