Effect of topical anaesthetics on interstitial colloid osmotic pressure in human subcutaneous tissue sampled by wick technique

Hans Jørgen Timm Guthe, Torbjørn Nedrebø, Olav Tenstad, Helge Wiig, Ansgar Berg, Hans Jørgen Timm Guthe, Torbjørn Nedrebø, Olav Tenstad, Helge Wiig, Ansgar Berg

Abstract

Objectives: To measure colloid osmotic pressure in interstitial fluid (COP(i)) from human subcutaneous tissue with the modified wick technique in order to determine influence of topical application of anaesthetics, dry vs. wet wick and implantation time on COP(i).

Material and methods: In 50 healthy volunteers interstitial fluid (IF) was collected by subcutaneous implantation of multi-filamentous nylon wicks. Study subjects were allocated to two groups; one for comparing COP(i) obtained from dry and saline soaked wicks, and one for comparing COP(i) from unanaesthetized skin, and skin after application of a eutectic mixture of local anaesthetic (EMLA®, Astra Zeneca) cream. IF was sampled from the skin of the shoulders, and implantation time was 30, 60, 75, 90 and 120 min. Colloid osmotic pressure was measured with a colloid osmometer. Pain assessment during the procedure was compared for EMLA cream and no topical anaesthesia using a visual analogue scale (VAS) in a subgroup of 10 subjects.

Results: There were no significant differences between COP(i) obtained from dry compared to wet wicks, except that the values after 75 and 90 min. were somewhat higher for the dry wicks. Topical anaesthesia with EMLA cream did not affect COP(i) values. COP(i) decreased from 30 to 75 min. of implantation (23.2 ± 4.4 mmHg to 19.6 ± 2.9 mmHg, p = 0.008) and subsequently tended to increase until 120 min. EMLA cream resulted in significant lower VAS score for the procedure.

Conclusion: COP(i) from subcutaneous tissue was easily obtained and fluid harvesting was well tolerated when topical anaesthetic was used. The difference in COP(i) assessed by dry and wet wicks between 75 min. and 90 min. of implantation was in accordance with previous reports. The use of topical analgesia did not influence COP(i) and topical analgesia may make the wick technique more acceptable for subjects who dislike technical procedures, including children.

Trial registration: ClinicalTrials.gov NCT01044979.

Conflict of interest statement

Competing Interests: The authors have declared that no competing interests exist.

Figures

Figure 1. Colloid osmotic pressure and implantation…
Figure 1. Colloid osmotic pressure and implantation time.
Colloid osmotic pressure in interstitial fluid collected from wicks after various times of implantation. Significant difference (p) and between dry wicks from 30 to 75 min. with ().
Figure 2. Topical anaesthesia and colloid osmotic…
Figure 2. Topical anaesthesia and colloid osmotic pressure.
Colloid osmotic pressure in interstitial fluid collected from wet wicks inserted without (•) or after topical anaesthesia with EMLA (▴) plotted against duration of insertion. Mean COPi was 21.0 mmHg in the group without and 20.6 mmHg in the group with EMLA. No significant differences were found between the groups.
Figure 3. Distribution of macromolecules in interstitial…
Figure 3. Distribution of macromolecules in interstitial fluid.
High resolution size exclusion chromatography of plasma (black line) and interstitial fluid derived from: A; dry (red line) or wet (blue line) wicks, B; wet wicks with (red line) or without (blue line) topical anaesthetics. Wicks were collected after 60 min. of implantation. Ordinate: Absorption units at UV 210 normalized to the highest peak (HSA). Retention time for human serum albumin (HSA), IgG and alpha 2 macroglobulin (α2M) standards indicated. A small haemoglobin peak between 11 and 12 min. retention was usually seen in interstitial fluid.

References

    1. Starling EH. On the Absorption of Fluids from the Connective Tissue Spaces. J Physiol (Lond) 1896;19:312–326.
    1. Fadnes HO, Reed RK, Aukland K. Mechanisms regulating interstitial fluid volume. Lymphology. 1978;11:165–169.
    1. Aukland K, Fadnes HO. Protein concentration of interstitial fluid collected from rat skin by a wick method. Acta Physiol Scand. 1973;88:350–358.
    1. Fadnes H, Aukland K. Protein concentration and colloid osmotic pressure of interstitial fluid collected by the wick technicue: Analysis and evaluation of the method. Microvascular Research. 1977;14:11–25.
    1. Wiig H, Heir S, Aukland K. Colloid osmotic pressure of interstitial fluid in rat subcutis and skeletal muscle: comparison of various wick sampling techniques. Acta Physiol Scand. 1988;133:167–175.
    1. Kramer GC, Sibley L, Aukland K, Renkin EM. Wick sampling of interstitial fluid in rat skin: further analysis and modifications of the method. Microvascular Research. 1986;32:39–49.
    1. Heltne JK, Husby P, Koller ME, Lund T. Sampling of interstitial fluid and measurement of colloid osmotic pressure (COPi) in pigs: evaluation of the wick method. Lab Anim. 1998;32:439–445.
    1. Tollan A, Oian P, Fadnes HO, Maltau JM. Evidence for altered transcapillary fluid balance in women with the premenstrual syndrome. Acta Obstet Gynecol Scand. 1993;72:238–242.
    1. Noddeland H, Riisnes SM, Fadnes HO. Interstitial fluid colloid osmotic and hydrostatic pressures in subcutaneous tissue of patients with nephrotic syndrome. Scand J Clin Lab Invest. 1982;42:139–146.
    1. Khiabani HZ, Anvar MD, Kroese AJ, Stranden E. Transcapillary forces and the development of oedema in the lower limb of patients with chronic critical limb ischaemia (CLI). Eur J Vasc Endovasc Surg. 2000;19:598–604.
    1. Noddeland H. Colloid osmotic pressure of human subcutaneous interstitial fluid sampled by nylon wicks: evaluation of the method. Scand J Clin Lab Invest. 1982;42:123–130.
    1. Noddeland H. Influence of body posture on transcapillary pressures in human subcutaneous tissue. Scand J Clin Lab Invest. 1982;42:131–138.
    1. European Union. Ethical considerations for clinical trials on medicinal products conducted with the paediatric population. Eur J Health Law. 2008;15:223–250.
    1. Aukland K, Johnsen HM. A colloid osmometer for small fluid samples. Acta Physiol Scand. 1974;90:485–490.
    1. Wiig H, Halleland EG, Fjaertoft M, Aukland K. Measurement of colloid osmotic pressure in submicrolitre samples. Acta Physiol Scand. 1988;132:445–452.
    1. Oian P, Maltau JM, Noddeland H, Fadnes HO. Transcapillary fluid balance in pre-eclampsia. Br J Obstet Gynaecol. 1986;93:235–239.
    1. Oian P, Maltau JM, Noddeland H, Fadnes HO. Oedema-preventing mechanisms in subcutaneous tissue of normal pregnant women. Br J Obstet Gynaecol. 1985;92:1113–1119.
    1. Stranden E, Myhre HO. Transcapillary forces in patients with lower limb ischemia. Scand J Clin Lab Invest. 1983;43:233–239.
    1. Noddeland H, Omvik P, Lund-Johansen P, Ofstad J, Aukland K. Interstitial colloid osmotic and hydrostatic pressures in human subcutaneous tissue during early stages of heart failure. Clin Physiol. 1984;4:283–297.
    1. Koomans HA, Kortlandt W, Geers AB, Dorhout Mees EJ. Lowered protein content of tissue fluid in patients with the nephrotic syndrome: observations during disease and recovery. Nephron. 1985;40:391–395.
    1. Haaverstad R, Romslo I, Larsen S, Myhre HO. Protein concentration of subcutaneous interstitial fluid in the human leg. A comparison between the wick technique and the blister suction technique. Int J Microcirc Clin Exp. 1996;16:111–117.
    1. Semb KA, Aamdal S, Oian P. Capillary protein leak syndrome appears to explain fluid retention in cancer patients who receive docetaxel treatment. J Clin Oncol. 1998;16:3426–3432.
    1. Heradstveit BE, Guttormsen AB, Langorgen J, Hammersborg SM, Wentzel-Larsen T, et al. Capillary leakage in post-cardiac arrest survivors during therapeutic hypothermia - a prospective, randomised study. Scand J Trauma Resusc Emerg Med. 2010;18:29.
    1. Bates DO, Levick JR, Mortimer PS. Starling pressures in the human arm and their alteration in postmastectomy oedema. J Physiol. 1994;477(Pt 2):355–363.
    1. Bates DO, Levick JR, Mortimer PS. Change in macromolecular composition of interstitial fluid from swollen arms after breast cancer treatment, and its implications. Clin Sci (Lond) 1993;85:737–746.
    1. Aukland K, Reed RK. Interstitial-lymphatic mechanisms in the control of extracellular fluid volume. Physiol Rev. 1993;73:1–78.
    1. Poulsen HL. Subcutaneous interstitial fluid albumin concentration in long-term diabetes mellitus. Scand J Clin Lab Invest. 1973;32:167–173.
    1. Nilsson A, Boman I, Wallin B, Rotstein A. The EMLA patch–a new type of local anaesthetic application for dermal analgesia in children. Anaesthesia. 1994;49:70–72.
    1. Shaikh FM, Naqvi SA, Grace PA. The influence of a eutectic mixture of lidocaine and prilocaine on minor surgical procedures: a randomized controlled double-blind trial. Dermatol Surg. 2009;35:948–951.
    1. Riendeau LA, Bennett D, Black-Noller G, Fan L, Scavone JM. Evaluation of the analgesic efficacy of EMLA cream in volunteers with differing skin pigmentation undergoing venipuncture. Reg Anesth Pain Med. 1999;24:165–169.
    1. Abad F, Diaz-Gomez NM, Domenech E, Gonzalez D, Robayna M, et al. Oral sucrose compares favourably with lidocaine-prilocaine cream for pain relief during venepuncture in neonates. Acta Paediatr. 2001;90:160–165.
    1. Willatts DG, Reynolds F. Comparison of the vasoactivity of amide and ester local anaesthetics. An intradermal study. Br J Anaesth. 1985;57:1006–1011.
    1. Bjerring P, Andersen PH, Arendt-Nielsen L. Vascular response of human skin after analgesia with EMLA cream. Br J Anaesth. 1989;63:655–660.
    1. Ashley EM, Quick DG, El-Behesey B, Bromley LM. A comparison of the vasodilatation produced by two topical anaesthetics. Anaesthesia. 1999;54:466–469.
    1. AstraZeneca. Emla Cream product information. 2005. Available: . Accessed 2012 Jan 11.

Source: PubMed

3
S'abonner