Feasibility Evaluation of an Artificial Pancreas With Glucose Prediction Trust Index

10 luglio 2018 aggiornato da: Jordan Pinsker, Sansum Diabetes Research Institute

Feasibility Evaluation of an Artificial Pancreas With an Enhanced Model Predictive Control (eMPC) Controller and a Health Monitoring System (HMS) With a Glucose Prediction Trust Index

The purpose of this pilot study is to establish that closed-loop insulin delivery with a target enchanted model predictive control (eMPC)/Health Monitoring System (HMS) algorithms with a trust index of the predicted glucose value is safe and effective, to analyze and learn to improve upon the accuracy of the predicted glucose values, and to collect efficacy data to inform a future larger study.

Panoramica dello studio

Stato

Completato

Descrizione dettagliata

This is a feasibility study of an artificial pancreas (AP) system with our previously validated target eMPC and HMS algorithms, with the addition of a trust index of the predicted glucose value integrated into the portable Artificial Pancreas System (pAPS). The system will be evaluated on up to 20 subjects, with the goal of 10 subjects completing a 48-hour closed-loop session at one clinical site (William Sansum Diabetes Center). During the session subjects will bolus for all meals and snacks and perform a 45-minute walking session.

The purpose of this pilot study is to establish that closed-loop insulin delivery with a target enchanted model predictive control (eMPC)/Health Monitoring System (HMS) algorithms with a trust index of the predicted glucose value is safe and effective, to analyze and learn to improve upon the accuracy of the predicted glucose values, and to collect efficacy data to inform a future larger study.

Tipo di studio

Interventistico

Iscrizione (Effettivo)

15

Fase

  • Non applicabile

Contatti e Sedi

Questa sezione fornisce i recapiti di coloro che conducono lo studio e informazioni su dove viene condotto lo studio.

Luoghi di studio

    • California
      • Santa Barbara, California, Stati Uniti, 93105
        • William Sansum Diabetes Center

Criteri di partecipazione

I ricercatori cercano persone che corrispondano a una certa descrizione, chiamata criteri di ammissibilità. Alcuni esempi di questi criteri sono le condizioni generali di salute di una persona o trattamenti precedenti.

Criteri di ammissibilità

Età idonea allo studio

Da 18 anni a 75 anni (Adulto, Adulto più anziano)

Accetta volontari sani

No

Sessi ammissibili allo studio

Tutto

Descrizione

Inclusion Criteria:

  • Age ≥ 18 and ≤ 75 years at the time of screening.
  • Clinical diagnosis of type 1 diabetes for at least one year.
  • Has been using an insulin pump for at least 6 months at the time of screening.
  • HbA1c < 10%, as performed by point of care or central laboratory testing. A1c will be assessed at the screening visit, or if already completed within 2 months of the screening visit, the prior lab value may be used in lieu of repeating this assessment.
  • Serum creatinine of < 2.0 mg/dL. Serum creatinine will be assessed at the screening visit, or if already completed within 2 months of the screening visit, the prior lab value may be used in lieu of repeating this assessment.
  • Bolus for all meals and snacks that contain ≥ 5 grams of carbohydrate.
  • Willing to perform at least 7 fingerstick blood glucose tests a day.
  • Willing to refrain from taking acetaminophen products for the duration of the clinical trial. If acetaminophen is taken, subject is to avoid making any insulin dosing decisions based on CGM for at least 12 hours.
  • Willing to abide by the study protocol and use study-provided devices, including the Omnipod, Dexcom CGM, glucometer, ketone meter and pAPS tablet.

Exclusion Criteria:

  • Pregnancy
  • One or more episodes of hypoglycemia requiring an emergency room visit or hospitalization in the past 6 months.
  • One or more episodes of hyperglycemia requiring an emergency room visit or hospitalization in the past 6 months.
  • Known unstable cardiac disease or untreated cardiac disease, as revealed by history or physical examination.
  • Dermatological conditions that would preclude wearing a CGM sensor or Pod.
  • One or more seizures in the past year.
  • Screening A1c ≥ 10% or serum creatinine ≥ 2.0 mg/dL.
  • Any condition that could interfere with participating in the trial, based on investigator judgment.
  • Concurrent use of any non-insulin glucose-lowering agent (including GLP-1 agonists, Symlin, DPP-4 inhibitors, SGLT-2 inhibitors, biguanides, sulfonylureas and naturaceuticals), defined as using any of these medications within 30 days of the screening visit or during the study.
  • Participation in another pharmaceutical or device trial at the time of enrollment or during the study.

Piano di studio

Questa sezione fornisce i dettagli del piano di studio, compreso il modo in cui lo studio è progettato e ciò che lo studio sta misurando.

Come è strutturato lo studio?

Dettagli di progettazione

  • Scopo principale: Trattamento
  • Assegnazione: N / A
  • Modello interventistico: Assegnazione di gruppo singolo
  • Mascheramento: Nessuno (etichetta aperta)

Armi e interventi

Gruppo di partecipanti / Arm
Intervento / Trattamento
Sperimentale: Artificial Pancreas
The artificial pancreas device will employ its enhanced Model Predictive Control (MPC) algorithm with a target glucose level of 110 mg/dL with a trust index for MPC-predicted glucose values, weighing future glucose predictions and only acting on predictions with higher weight in the trust index. The Health Monitoring System algorithm uses the same CGM data as the MPC control algorithm but utilizes a separate algorithm for trending and predictions of future glucose values. Using a redundant and independent algorithm is an important safety feature of the overall AP device.
Artificial Pancreas Device

Cosa sta misurando lo studio?

Misure di risultato primarie

Misura del risultato
Misura Descrizione
Lasso di tempo
Percent time within the target glucose range of 70-180 mg/dl overall as assessed by continuous glucose monitoring (CGM).
Lasso di tempo: 48 hours
The primary endpoint for this pilot study will be time within the target glucose range of 70-180 mg/dl overall as assessed by continuous glucose monitoring (CGM), during closed-loop use, determining if the combination of eMPC and the assessment of trust index can provide safe and effective glucose control.
48 hours

Misure di risultato secondarie

Misura del risultato
Misura Descrizione
Lasso di tempo
Assessment of the trust index predictions vs. standard eMPC glucose predictions.
Lasso di tempo: 48 hours
During closed-loop use, assessment of the trust index predictions vs. standard eMPC glucose predictions (frequency of moving away from nominal weights of predicted glucose).
48 hours
Frequency of hypoglycemia during closed-loop use.
Lasso di tempo: 48 hours
Frequency of hypoglycemia during closed-loop use, defined as percent time glucose is below predefined thresholds of 70 mg/dl, 60 mg/dl and 50 mg/dL.
48 hours
Frequency of hyperglycemia during closed-loop use.
Lasso di tempo: 48 hours
Frequency of hyperglycemia during closed-loop use, defined as percent time glucose is above predefined thresholds of 180 mg/dl, 250 mg/dl, and 300 mg/dL.
48 hours
Percent time within the target glucose range of 70-140 mg/dl during closed-loop use.
Lasso di tempo: 48 hours
Percent time within the target glucose range of 70-140 mg/dl overall as assessed by continuous glucose monitoring (CGM), during closed-loop use.
48 hours
Percent time glucose is within range 70-150 mg/dl postprandial within 5 hours following meals, during closed-loop use.
Lasso di tempo: 48 hours
Percent time glucose is within range 70-150 mg/dl postprandial within 5 hours following meals, during closed-loop use.
48 hours
Standard Deviation and Coefficient of Variation of glucose values
Lasso di tempo: 48 hours
To measure glycemic variability, the standard deviation and coefficient of variation of glucose values (as measured by continuous glucose monitoring) will be determined during the 48 hours of closed-loop use.
48 hours
Markers of hypo- and hyperglycemia
Lasso di tempo: 48 hours
Markers of hypo- and hyperglycemia, to include LBGI (Low blood glucose index) and HBGI (High blood glucose index), during closed-loop use.
48 hours
Insulin Doses Given
Lasso di tempo: 48 hours
Change in total daily doses and post prandial insulin doses given during the 48 hours of closed-loop use.
48 hours
Number of treatments given for hypoglycemia (defined as carbohydrates given for treatment of a documented or suspected low blood sugar), during the 48 hours of closed-loop use.
Lasso di tempo: 48 hours
Treatments for hypoglycemia given during the 48 hours of closed-loop use. Hypoglycemia treatments may be given in response to alerts from the HMS, if blood glucose < 70 mg/dL, or at the request of the subject or investigator.
48 hours
Number of alerts given by the HMS to prevent hypoglycemia
Lasso di tempo: 48 hours
Number of alerts given by the HMS to prevent hypoglycemia during closed-loop use.
48 hours
Failure analysis of the devices/connectivity issues that may occur (# disconnects and device restarts).
Lasso di tempo: 48 hours
Failure analysis of the devices/connectivity issues that may occur during closed-loop use. This includes number of CGM communication losses with 3 or more missed points, and number of times the entire system required a restart.
48 hours

Collaboratori e investigatori

Qui è dove troverai le persone e le organizzazioni coinvolte in questo studio.

Collaboratori

Investigatori

  • Investigatore principale: Eyal Dassau, PhD, Harvard John A. Paulson School of Engineering and Applied Sciences, Harvard University
  • Investigatore principale: Francis J Doyle III, PhD, Harvard John A. Paulson School of Engineering and Applied Sciences, Harvard University
  • Investigatore principale: Alejandro Leguna, PhD, Harvard John A. Paulson School of Engineering and Applied Sciences, Harvard University

Pubblicazioni e link utili

La persona responsabile dell'inserimento delle informazioni sullo studio fornisce volontariamente queste pubblicazioni. Questi possono riguardare qualsiasi cosa relativa allo studio.

Studiare le date dei record

Queste date tengono traccia dell'avanzamento della registrazione dello studio e dell'invio dei risultati di sintesi a ClinicalTrials.gov. I record degli studi e i risultati riportati vengono esaminati dalla National Library of Medicine (NLM) per assicurarsi che soddisfino specifici standard di controllo della qualità prima di essere pubblicati sul sito Web pubblico.

Studia le date principali

Inizio studio (Effettivo)

20 marzo 2017

Completamento primario (Effettivo)

20 dicembre 2017

Completamento dello studio (Effettivo)

20 dicembre 2017

Date di iscrizione allo studio

Primo inviato

15 marzo 2017

Primo inviato che soddisfa i criteri di controllo qualità

20 marzo 2017

Primo Inserito (Effettivo)

27 marzo 2017

Aggiornamenti dei record di studio

Ultimo aggiornamento pubblicato (Effettivo)

12 luglio 2018

Ultimo aggiornamento inviato che soddisfa i criteri QC

10 luglio 2018

Ultimo verificato

1 luglio 2018

Maggiori informazioni

Termini relativi a questo studio

Piano per i dati dei singoli partecipanti (IPD)

Hai intenzione di condividere i dati dei singoli partecipanti (IPD)?

NO

Informazioni su farmaci e dispositivi, documenti di studio

Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti

No

Studia un dispositivo regolamentato dalla FDA degli Stati Uniti

Sì

Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .

Sottoscrivi