- ICH GCP
- Registro degli studi clinici negli Stati Uniti
- Sperimentazione clinica NCT05251506
The Evaluation of Laser Lancing Devices in Adult Type 2 Diabetes Patients
The Evaluation of Laser Lancing Devices in Constructing Self-management Systems for Chronic Diseases in Adult Diabetes Patients
Self monitoring of blood glucose level is crucial in diabetes management, but currently available methods, lancet, have shown low compliance of self monitoring of blood glucose because of pain, keratinization of finger tip, secondary infection. The purpose of this study is evaluating laser lancing device which cause much less pain than lancet to increase compliance of blood sugar checking, and to establish self monitoring system for patients of chronic diseases.
The investigators recruit total of 80 type 2 diabetes patients who visit Korea University Medical center Guro and Ansan hospital. HbA1c level of subject is more than 6.5% and less than 8.5%, and their age is above 20 years and under 80 years. Subjects are randomly distributed in group A or B. Group A subjects use laser device to check blood glucose for 2 months, then take a month for wash out period. After wash out period, participants use lancet for following 2 months. Group B perform the process vice versa. The investigators evaluate the number of blood glucose measurement, HbA1c, diabetes distress scale, average pain score, average satisfaction score from each group.
Panoramica dello studio
Stato
Condizioni
Intervento / Trattamento
Descrizione dettagliata
Self monitoring of blood glucose level is crucial in diabetes management, so it is important to increase compliance of blood glucose checking. Lancet which is currently available methods have shown low compliance of self monitoring of blood glucose, since it causes pain, keratinization of finger tip, secondary infection. The purpose of this study is evaluating laser lancing device which cause much less pain than lancet to increase compliance of blood sugar checking, and to establish self monitoring system for patients of chronic diseases.
The investigators recruit total of 80 subjects who visit Korea University Medical center Guro and Ansan hospital. Study subject are type 2 diabetes whose glycated hemoglobin level is more than 6.5% and less than 8.5%, and whose age is more than 20 years and under 80 years. Subjects are randomly distributed in group A or B. Group A subjects use laser device to check blood glucose for 2 months, then take a month for wash out period. After wash out period, participants use lancet for following 2 months. Group B subjects use lancet first, then have a month for wash out period, after then, switch to laser device afterwards. During washout period, participants use usual glucose checking method which subjects had used. The investigators evaluate the number of blood glucose measurement, glycated hemoglobin, diabetes distress scale, average pain score, average satisfaction score from each group. Also the investigators compare blood glucose, liver function test, lipid level between values from one hand measured by lancet, and values from the other hand measured by laser lancing device.
Tipo di studio
Iscrizione (Anticipato)
Fase
- Non applicabile
Contatti e Sedi
Contatto studio
- Nome: Min Jeong Park
- Numero di telefono: +82-10-7271-3805
- Email: minjeong87@gmail.com
Backup dei contatti dello studio
- Nome: Hye Jin Yoo
- Numero di telefono: +82-10-8951-9451
- Email: deisy21@naver.com
Luoghi di studio
-
-
-
Seoul, Corea, Repubblica di, 08308
- Reclutamento
- Korea University Medical Center
-
Contatto:
- Min Jeong Park, M.D.
- Numero di telefono: +82-10-7271-3805
- Email: minjeong87@gmail.com
-
Contatto:
- Hye Jin Yoo, M.D. Ph.D
- Numero di telefono: +82-10-8951-9451
- Email: deisy21@naver.com
-
-
Criteri di partecipazione
Criteri di ammissibilità
Età idonea allo studio
Accetta volontari sani
Sessi ammissibili allo studio
Descrizione
Inclusion Criteria:
- Type 2 diabetes patients who visit Korea University medical center, Guro hospital, Ansan hospital
- Patients with Hba1c more than 6.5% and less than 8.5%
- Adults who are able to measure blood glucose level by themselves
- Adults who are able to lance their same finger from both hands
- Adults who comprehend risk of participating in the clinical research, who are able to communicate each other, who are able to follow rules of clinical research
- Subjects who decide to participate in the clinical research voluntarily and sign in the consent format after being informed purposes, methods, expectations of the clinical research
Exclusion Criteria:
- Subject whose age is younger than 19 or older than 80
- students of research institutes
- Pregnant and lactating women
- Subjects who are not able to make decision
- Subjects who are in emergency or being hospitalized
- Subjects who cannot lance sane finger from both hands
- Subjects who are infected by HIV in hospital records
- Subjects who have thrombocytopenia, coagulation disorder or haemophilia
- Subjects who are incompatible for clinical research as researcher evaluated
Piano di studio
Come è strutturato lo studio?
Dettagli di progettazione
- Scopo principale: Trattamento
- Assegnazione: Randomizzato
- Modello interventistico: Assegnazione incrociata
- Mascheramento: Separare
Armi e interventi
Gruppo di partecipanti / Arm |
Intervento / Trattamento |
|---|---|
|
Sperimentale: laser lancing device (LMT-1000) first user
Subjects measure blood glucose using laser lancing device (LMT-1000) for first 2 months, then take a month for wash out period, after that do using lancet for following 2 months.
|
Subjects measure blood glucose level using laser lancing device (LMT-1000) and lancet for 2 months each.
|
|
Comparatore attivo: lancet first user
Subjects measure blood glucose using lancet for first 2 months, , then take a month for wash out period, after that do using laser lancing device (LMT-1000) for following 2 months.
|
Subjects measure blood glucose level using laser lancing device (LMT-1000) and lancet for 2 months each.
|
Cosa sta misurando lo studio?
Misure di risultato primarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
average number of checking blood glucose per week
Lasso di tempo: two months after using the device
|
Study subject is going to be surveyed about 'average number of checking blood glucose per week' at 2 month after using lancet device, and 2 month after using laser lancing device (LMT-1000)
|
two months after using the device
|
|
glycated hemoglobin level
Lasso di tempo: two months after using the device
|
Study subject is going to be checked glycated hemoglobin level at 2 month after using lancet device, and 2 month after using laser lancing device (LMT-1000).
Data will be shown in percent (%).
|
two months after using the device
|
Misure di risultato secondarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
average satisfaction score
Lasso di tempo: two months after using the device
|
Study subject is going to be surveyed about 'average satisfaction score' at 2 month after using lancet device, and 2 month after using laser lancing device (LMT-1000)
|
two months after using the device
|
|
average pain scale
Lasso di tempo: two months after using the device
|
Study subject is going to be surveyed about 'average pain scale' at 2 month after using lancet device, and 2 month after using laser lancing device (LMT-1000)
|
two months after using the device
|
|
Diabetes Distress Scale
Lasso di tempo: two months after using the device
|
Study subject is going to be surveyed about 'Diabetes Distress Scale' at 2 month after using lancet device, and 2 month after using laser lancing device (LMT-1000)
|
two months after using the device
|
|
Diabetes Fear of Self-injecting
Lasso di tempo: two months after using the device
|
Study subject is going to be surveyed about 'Diabetes Fear of Self injecting' at 2 month after using lancet device, and 2 month after using laser lancing device (LMT-1000)
|
two months after using the device
|
|
success rate of measurement of blood glucose by laser lancing device
Lasso di tempo: two months after using the device
|
Study subject is going to be surveyed about 'success rate of measurement of blood glucose by laser lancing device' at 2 month after using lancet device, and 2 month after using laser lancing device (LMT-1000)
|
two months after using the device
|
Collaboratori e investigatori
Sponsor
Collaboratori
Studiare le date dei record
Studia le date principali
Inizio studio (Effettivo)
Completamento primario (Anticipato)
Completamento dello studio (Anticipato)
Date di iscrizione allo studio
Primo inviato
Primo inviato che soddisfa i criteri di controllo qualità
Primo Inserito (Effettivo)
Aggiornamenti dei record di studio
Ultimo aggiornamento pubblicato (Effettivo)
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo verificato
Maggiori informazioni
Termini relativi a questo studio
Termini MeSH pertinenti aggiuntivi
Altri numeri di identificazione dello studio
- K2021-1520-002
Piano per i dati dei singoli partecipanti (IPD)
Hai intenzione di condividere i dati dei singoli partecipanti (IPD)?
Informazioni su farmaci e dispositivi, documenti di studio
Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti
Studia un dispositivo regolamentato dalla FDA degli Stati Uniti
Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .