Optical Coherence TomOgraphy Assessment of the Drug-Eluting Stent (OCTOBER)

2009年11月12日 更新者:Chinese PLA General Hospital

Optical Coherence TomOgraphy Assessment of the Excel Drug-Eluting Stent With BiodegradablE polymeR vs. the Cypher Drug-Eluting Stent With Permanent Polymer

BACKGROUND Treatment of coronary atherosclerotic disease has been significantly advanced by interventional cardiology, and the advent of coronary arterial stents. In comparison to angioplasty alone, stents have reduced the incidence of angiographic as well as clinical restenosis, the recurrence of angina, the need for coronary arterial bypass graft (CABG) surgery, repeat revascularization and the occurrence of major adverse cardiac events (MACE).However the long-term success of this therapy has been limited by the occurrence of in-stent restenosis. Despite the effectiveness of intracoronary stents in maintaining a larger luminal diameter, as compared to angioplasty alone, in-stent restenosis occurs within 6 to 9 months after stent placement in 15% to 35% of patients. While stents can reduce restenosis by blocking vascular recoil and remodeling, mechanical intervention alone has been incapable of treating this biological problem of neointimal hyperplasia, particularly in the subset of patients with diabetes, long lesions or small vessel disease.Drug-eluting stents (DES) were developed as a viable method for focused delivery of anti-restenosis compounds to target lesions for the reduction of restenosis. Of the DES available and with the results of up to six (6) years clinical follow-up, the sirolimus-eluting stent (SES) has become the current gold standard for stent implantation. With the advent of using DES to treat complex lesions such as longer lesions requiring the use of multiple stents and the use in bifurcation lesions, the risk of stent thrombosis has increase.Late stent thrombosis has also been reported following DES implantation.Long term treatment with dual anti-platelet therapy following stent implantation has become the solution used to counteract the risk of stent thrombosis, this solution does not come without it's own risks and is an expensive therapy. Another specific problem of DES is delayed endothelization, and this may be and attributing factor in prolonging the period of thrombotic risk as shown by pathological findings at autopsy following SES implantation. These examinations have shown that even after 16 months, neointimal healing is still incomplete with approximately 20% of stent struts being found uncovered. Questions have arose that the problems of late thrombosis and delayed endothelization of stent struts with DES could be the result of the permanent polymer that is used as the bonding agent for the anti-restenosis compounds to the stents.Intravascular Ultrasound (IVUS) along with angiography has been the techniques used to gain data on DES to this point. Angiography is a 2 dimensional tool that gives a view of the vessel and IVUS gives a more 3 dimensional view of the vessel. IVUS does have its limitations, as stent struts are reflectors of sonic waves, shadowing around and behind the struts occurs. IVUS is also limited in detecting malapposition of the struts to the vessel wall especially if the area between the vessel wall and the strut in very small.

RATIONALE Optical Coherence Tomography (OCT) is an optical analogue of IVUS that uses an infrared light source and measures the backscatter of the light. With this technique a higher level of resolution compared with IVUS has been reported.OCT has been reported as being able to visualize and detect atherosclerotic plaques and assess more accurately strut malapposition and the presence or thickness of neointimal hyperplasia as compared to IVUS. With the question of delayed endothelization due to the permanent polymer being a probable risk for late stent thrombosis, it is felt that OCT post stent implantation may give a more accurate assessment of stent strut endothelial coverage.

This study is designed to compare the intimal hyperplasia following implantation of the Excel DES with a biodegradable polymer vs. the Cypher DES with a permanent polymer using OCT.

調査の概要

状態

わからない

研究の種類

観察的

入学 (予想される)

1

参加基準

研究者は、適格基準と呼ばれる特定の説明に適合する人を探します。これらの基準のいくつかの例は、人の一般的な健康状態または以前の治療です。

適格基準

就学可能な年齢

18年~75年 (大人、高齢者)

健康ボランティアの受け入れ

いいえ

受講資格のある性別

全て

サンプリング方法

確率サンプル

調査対象母集団

This study intends to enroll up to 100 patients from a single center in China. Patients will be randomized in a 1:1 fashion, Excel DES:Cypher DES.

説明

Inclusion Criteria:

  • Age between 30 and 75 years.
  • Binary stenosis of > 70% in a de novo lesion in native coronary artery.
  • Reference lumen diameter proximal to the target lesion is 2.5 mm and < 4.0 mm.
  • Reference lesion length of < 30 mm.
  • The target lesioin can be covered with a makimum of two overlapping stents at a single lesion.
  • Written informed consent has been signed.

Exclusion Criteria:

  • Pregnant or breast feeding woman.
  • Intolerance to aspirin, clopidogrel (Plavix®), ticlopidine(Ticlid®), heparin, bivalirudin, stainless steel, contrast agent(that cannot be adequately premedicated), parylene, poly-lacticacid (PLA), or Biolimus A9 (or its analogues).
  • Lesion located in a protected or unprotected Left Main Coronary Artery.
  • STEMI within 72 hours prior to index procedure.
  • The patient has had another drug-eluting stent (DES) implanted within 12 months prior to the index procedure.
  • CCS Class III patients or the patient has a LVEF of < 40%.
  • Diffuse lesions of > 40 mm in length.
  • Renal impairment, with a serum creatinine of > 2.0 mg/dl.
  • Complicated anatomy such as Chronic Total Occlusion (CTO),Bifurcation Lesions (with side branch of > 2.5 mm) or Triple Vessel Disease (TVD).
  • Lesion cannot be pre-dilated successfully.
  • History of gastritis and/or bleeding history which will limit the usual dual anti-platelet regime.
  • Patient has a co-morbid condition(s) that could limit his/her ability to participate in the study, comply with follow-up requirements and impact the scientific integrity of the study.

研究計画

このセクションでは、研究がどのように設計され、研究が何を測定しているかなど、研究計画の詳細を提供します。

研究はどのように設計されていますか?

デザインの詳細

この研究は何を測定していますか?

主要な結果の測定

結果測定
時間枠
To quantitate the presence of neointimal stent strut coverage at 6 month via Optical Coherence Tomography follow-up.
時間枠:6 month
6 month

二次結果の測定

結果測定
時間枠
1.Stent strut apposition at 6 month follow-up. 2. Neointimal thickness at 6 month follow-up. 3. late loss at 6 months 4. Major Adverse Cardiac Events
時間枠:12 month
12 month

協力者と研究者

ここでは、この調査に関係する人々や組織を見つけることができます。

研究記録日

これらの日付は、ClinicalTrials.gov への研究記録と要約結果の提出の進捗状況を追跡します。研究記録と報告された結果は、国立医学図書館 (NLM) によって審査され、公開 Web サイトに掲載される前に、特定の品質管理基準を満たしていることが確認されます。

主要日程の研究

研究開始

2009年11月1日

一次修了 (予想される)

2010年10月1日

研究の完了 (予想される)

2010年10月1日

試験登録日

最初に提出

2009年11月12日

QC基準を満たした最初の提出物

2009年11月12日

最初の投稿 (見積もり)

2009年11月13日

学習記録の更新

投稿された最後の更新 (見積もり)

2009年11月13日

QC基準を満たした最後の更新が送信されました

2009年11月12日

最終確認日

2009年11月1日

詳しくは

この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。

3
購読する