A Pilot Study to Evaluate the Safety and Efficacy of the Apica Access, Stabilization and Closure (ASC™) Device

2014年6月26日 更新者:Apica Cardiovascular Limited

A Pilot Study to Evaluate the Safety and Efficacy of the Apica Access, Stabilization and Closure (ASC™) Device During and After Transcatheter Aortic Valve Implantation (TAVI) Procedures

A pilot study to evaluate the safety and efficacy of the Apica Access, Stabilization, and Closure Device for accessing and closing the left ventricular apex during and after Transcatheter Aortic Valve Implantation (TAVI) procedures. Follow-up assessment will be made post-procedure, at 30 days and 90 days as well as longer term follow-up.

調査の概要

研究の種類

介入

入学 (実際)

31

段階

  • フェーズ2
  • フェーズ 1

参加基準

研究者は、適格基準と呼ばれる特定の説明に適合する人を探します。これらの基準のいくつかの例は、人の一般的な健康状態または以前の治療です。

適格基準

就学可能な年齢

18年歳以上 (大人、高齢者)

健康ボランティアの受け入れ

いいえ

受講資格のある性別

全て

説明

Inclusion Criteria:

  • Subject age ≥ 18 years of age.
  • Subjects will be selected in accordance with the investigating centers standard operating procedures for TAVI subject selection and treatment. Subjects selected will meet all of the TAVI inclusion criteria as follows:

    • Subject has Senile degenerative aortic stenosis with echocardiography derived criteria: mean gradient > 40 mm Hg or jet velocity > 4.0 m/s or an aortic valve area (AVA) of < 0.8 cm2 (or AVA index < 0.5 cm2/m2.
    • Subject is symptomatic due to aortic valve stenosis as demonstrated by NYHA Functional Class > II.
    • Additive EuroScore > 9
    • Aortic annulus diameter > 21mm to < 27mm by TEE
    • The subject or the subject's legal representative has been informed of the nature of the study, agrees to its provisions and has provided written informed consent.
    • The subject and the treating physician agree that the subject will return for all required post-procedure follow-up visits.
    • The subject, after formal consults by a cardiologist and two cardiovascular surgeons agreed that medical factors precluding operation, based on a conclusion that the probability of death or serious, irreversible morbidity exceeded the probability of meaningful improvement. Specifically the probability of death or serious, irreversible morbidity exceeded 50%.

Exclusion Criteria:

Subjects will be selected in accordance with the investigating centers standard operating procedures for TAVI subject selection and treatment. The following TAVI exclusion criteria shall apply:

  • Evidence of an acute myocardial infarction < 1 month before the intended treatment
  • Aortic valve is a congenital unicuspid or bicuspid valve; or is non-calcified
  • Mixed aortic valve disease (aortic stenosis and aortic regurgitation with predominant aortic regurgitation > 3+)
  • Pre-existing prosthetic heart valve in an position, prosthetic ring, or severe (greater than 3+) mitral insufficiency
  • Blood dyscrasias as defined: Leukopenia, acute anemia, thrombocytopenia, history of bleeding diathesis or coagulopathy.
  • Untreated clinically significant coronary artery disease requiring revascularization
  • Hemodynamic instability requiring inotropic therapy or mechanical hemodynamic support devices
  • Need for emergency surgery for any reason
  • Hypertrophic cardiomyopathy with or without obstruction
  • Echocardiographic evidence of intracardiac mass, thrombus or vegetation
  • Active peptic ulcer or upper gastro-intestinal bleeding within the prior 3 months
  • A known hypersensitivity of contraindication to asprin, heparin, ticlopidine (Ticlid), or clopidogrel (Plavix), or sensitivity to contrast media, which cannot be adequately pre-medicated
  • Recent (within 6 months) cerebrovascular accident or transient ischemic attack
  • Renal insufficiency and/or end stage renal disease requiring chronic dialysis.
  • Life expectancy < 12 months due to non-cardiac co-morbid conditions.

The following ASC device exclusion criteria shall apply:

  • Subjects with <10mm Left ventricular wall thickness at apical access site
  • LVEF < 30%
  • Subject with previous DOR procedure
  • Subject access site has less than 2 cm squared "fat" free area under visual observation
  • Subject has known Allergy or hypersensitivity to Titanium
  • Subject requires MR Imaging post procedure
  • Subject is Pregnant

研究計画

このセクションでは、研究がどのように設計され、研究が何を測定しているかなど、研究計画の詳細を提供します。

研究はどのように設計されていますか?

デザインの詳細

  • 主な目的:処理
  • 割り当て:なし
  • 介入モデル:単一グループの割り当て
  • マスキング:なし(オープンラベル)

武器と介入

参加者グループ / アーム
介入・治療
実験的:Apica Cardiovascular ASC Device
Access, stabilisation and closure with the Apica Cardiovascular ASC Device
Access, stabilisation and closure of trans-apical approach for TAVI
他の名前:
  • Apica Cardiovascular, ASC

この研究は何を測定していますか?

主要な結果の測定

結果測定
メジャーの説明
時間枠
Access safety
時間枠:Within 2 hours from initial skin incision
Observation of no myocardial tearing on entry of the device
Within 2 hours from initial skin incision
Closure safety
時間枠:Within 2 hours from initial skin incision
Observation of no acute post-procedural bleeding or pericardial effusion.
Within 2 hours from initial skin incision

二次結果の測定

結果測定
メジャーの説明
時間枠
Investigational device performance: LV function
時間枠:24 hours, 30 days and 90 days post-procedure
% LVEF no worse than baseline as assessed by echocardiography
24 hours, 30 days and 90 days post-procedure

協力者と研究者

ここでは、この調査に関係する人々や組織を見つけることができます。

捜査官

  • 主任研究者:Thomas Walther, Prof、Kerckhoff Klinik

研究記録日

これらの日付は、ClinicalTrials.gov への研究記録と要約結果の提出の進捗状況を追跡します。研究記録と報告された結果は、国立医学図書館 (NLM) によって審査され、公開 Web サイトに掲載される前に、特定の品質管理基準を満たしていることが確認されます。

主要日程の研究

研究開始

2012年5月1日

一次修了 (実際)

2013年1月1日

研究の完了 (実際)

2013年3月1日

試験登録日

最初に提出

2012年9月25日

QC基準を満たした最初の提出物

2012年11月2日

最初の投稿 (見積もり)

2012年11月6日

学習記録の更新

投稿された最後の更新 (見積もり)

2014年6月27日

QC基準を満たした最後の更新が送信されました

2014年6月26日

最終確認日

2014年6月1日

詳しくは