Comparison of the Vasomotor Function and Myocardial Flow in Patients Treated With Bioresorbable and Metallic Stents at 1 Year (BVS-Flow)
Comparison of the Vasomotor Function and Myocardial Flow in Patients Treated
Background: A total of 25-50% of patients with stable coronary atherosclerosis treated with metallic stent implantation remain with effort angina despite optimal medical treatment and absence of stent restenosis at 1 year. The most plausible cause of persistent effort angina after stent implantation is microcirculatory dysfunction. Coronary circulation matches the myocardial blood supply and oxygen consumption. Metallic stent implantation has been related with endothelial dysfunction and impaired coronary blood flow reserve (relation between coronary blood flow at rest and maximal hyperemia) of the treated vessel at 1 year.
Bioresorbable Vascular Scaffold (BVS) has been shown to improve the endothelial function and to improve the angina symptoms at 1 year. However, the coronary blood flow of BVS has never been tested.
Main objective: To determine differences in the blood average peak velocity at maximal hyperemia with adenosine infusion between patients treated with bioresorbable and metallic coronary stents at 1 year after stent implantation.
Methodology: A total of 70 patients are 1:1 randomized to everolimus-eluting metallic stent (EES) versus everolimus-eluting BVS implantation in patients with stable coronary disease. At 1 year, patients undergo to invasive coronary angiography prior cessation of vasomotor drugs. A pressure/Doppler wire is advanced distally to the "treated segment" and the endothelial (acetylcholine) and non-endothelial (adenosine and nitroglycerine) vasomotor function is assessed with quantitative coronary angiography and pressure and Doppler measurements. Angina test questionnaires are obtained at different time-points of the study.
Expected results: A difference between patients treated with BVS and EES of 12.0 cm/sc in the maximal average peak velocity (APV) under maximal hyperemia (with adenosine administration) is expected, as assessed by Doppler measurements, at 1 year after stent implantation. The study is powered to assess superiority in terms of maximal APV favoring patients treated with BVS.
調査の概要
研究の種類
入学 (実際)
段階
- フェーズ 4
連絡先と場所
研究場所
-
-
-
Barcelona、スペイン、08003
- Hospital Del Mar
-
Barcelona、スペイン、08036
- Hospital Clinic
-
-
Barcelona
-
L´Hospitalet de Llobregat、Barcelona、スペイン、08173
- Hospital Universitari de Bellvitge
-
-
参加基準
適格基準
就学可能な年齢
健康ボランティアの受け入れ
受講資格のある性別
説明
Inclusion Criteria:
- Patients with stable angina or silent angina with myocardial ischemia detected by non-invasive tests or patients with acute coronary syndromes with no increase of > 5 times the upper value of normality of cardiac biomarkers (troponin).
- Patients with coronary artery disease with angiographic stenosis >
研究計画
研究はどのように設計されていますか?
デザインの詳細
- 主な目的:他の
- 割り当て:ランダム化
- 介入モデル:並列代入
- マスキング:独身
武器と介入
参加者グループ / アーム |
介入・治療 |
|---|---|
|
実験的:Bioresorbable vascular scaffold (BVS)
Patients with stable coronary angina with coronary artery disease suitable to be treated with a bioresorbable vascular scaffold.
|
他の名前:
|
|
アクティブコンパレータ:Everolimus-eluting stent (EES)
Patients with stable coronary angina with coronary artery disease suitable to be treated with a Everolimus-eluting stent .
|
この研究は何を測定していますか?
主要な結果の測定
結果測定 |
時間枠 |
|---|---|
|
Difference in the average peak velocity at maximal hyperemia between bioresorbable vascular scaffolds and everolimus-eluting stents as assessed by doppler wire measurement.
時間枠:1-year after stent implantation
|
1-year after stent implantation
|
二次結果の測定
結果測定 |
時間枠 |
|---|---|
|
Difference in endothelial dysfunction with acetyl-choline infusion between bioresorbable vascular scaffolds and everolimus-eluting stents as assessed by quantitative coronary angiography (4% of lumen reduction)
時間枠:1-year after stent implantation
|
1-year after stent implantation
|
その他の成果指標
結果測定 |
時間枠 |
|---|---|
|
Difference in fractional flow reserve at maximal hyperemia between the two treatment groups as assessed by pressure-wire measurement
時間枠:1-year after stent implantation
|
1-year after stent implantation
|
協力者と研究者
研究記録日
主要日程の研究
研究開始 (実際)
一次修了 (実際)
研究の完了 (実際)
試験登録日
最初に提出
QC基準を満たした最初の提出物
最初の投稿 (見積もり)
学習記録の更新
投稿された最後の更新 (実際)
QC基準を満たした最後の更新が送信されました
最終確認日
詳しくは
この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。