- ICH GCP
- USA klinikai vizsgálatok nyilvántartása
- Klinikai vizsgálat NCT02738658
Comparison of the Vasomotor Function and Myocardial Flow in Patients Treated With Bioresorbable and Metallic Stents at 1 Year (BVS-Flow)
Comparison of the Vasomotor Function and Myocardial Flow in Patients Treated
Background: A total of 25-50% of patients with stable coronary atherosclerosis treated with metallic stent implantation remain with effort angina despite optimal medical treatment and absence of stent restenosis at 1 year. The most plausible cause of persistent effort angina after stent implantation is microcirculatory dysfunction. Coronary circulation matches the myocardial blood supply and oxygen consumption. Metallic stent implantation has been related with endothelial dysfunction and impaired coronary blood flow reserve (relation between coronary blood flow at rest and maximal hyperemia) of the treated vessel at 1 year.
Bioresorbable Vascular Scaffold (BVS) has been shown to improve the endothelial function and to improve the angina symptoms at 1 year. However, the coronary blood flow of BVS has never been tested.
Main objective: To determine differences in the blood average peak velocity at maximal hyperemia with adenosine infusion between patients treated with bioresorbable and metallic coronary stents at 1 year after stent implantation.
Methodology: A total of 70 patients are 1:1 randomized to everolimus-eluting metallic stent (EES) versus everolimus-eluting BVS implantation in patients with stable coronary disease. At 1 year, patients undergo to invasive coronary angiography prior cessation of vasomotor drugs. A pressure/Doppler wire is advanced distally to the "treated segment" and the endothelial (acetylcholine) and non-endothelial (adenosine and nitroglycerine) vasomotor function is assessed with quantitative coronary angiography and pressure and Doppler measurements. Angina test questionnaires are obtained at different time-points of the study.
Expected results: A difference between patients treated with BVS and EES of 12.0 cm/sc in the maximal average peak velocity (APV) under maximal hyperemia (with adenosine administration) is expected, as assessed by Doppler measurements, at 1 year after stent implantation. The study is powered to assess superiority in terms of maximal APV favoring patients treated with BVS.
A tanulmány áttekintése
Állapot
Körülmények
Beavatkozás / kezelés
Tanulmány típusa
Beiratkozás (Tényleges)
Fázis
- 4. fázis
Kapcsolatok és helyek
Tanulmányi helyek
-
-
-
Barcelona, Spanyolország, 08003
- Hospital Del Mar
-
Barcelona, Spanyolország, 08036
- Hospital Clinic
-
-
Barcelona
-
L´Hospitalet de Llobregat, Barcelona, Spanyolország, 08173
- Hospital Universitari de Bellvitge
-
-
Részvételi kritériumok
Jogosultsági kritériumok
Tanulmányozható életkorok
Egészséges önkénteseket fogad
Tanulmányozható nemek
Leírás
Inclusion Criteria:
- Patients with stable angina or silent angina with myocardial ischemia detected by non-invasive tests or patients with acute coronary syndromes with no increase of > 5 times the upper value of normality of cardiac biomarkers (troponin).
- Patients with coronary artery disease with angiographic stenosis >
Tanulási terv
Hogyan készül a tanulmány?
Tervezési részletek
- Elsődleges cél: Egyéb
- Kiosztás: Véletlenszerűsített
- Beavatkozó modell: Párhuzamos hozzárendelés
- Maszkolás: Egyetlen
Fegyverek és beavatkozások
Résztvevő csoport / kar |
Beavatkozás / kezelés |
|---|---|
|
Kísérleti: Bioresorbable vascular scaffold (BVS)
Patients with stable coronary angina with coronary artery disease suitable to be treated with a bioresorbable vascular scaffold.
|
Más nevek:
|
|
Aktív összehasonlító: Everolimus-eluting stent (EES)
Patients with stable coronary angina with coronary artery disease suitable to be treated with a Everolimus-eluting stent .
|
Mit mér a tanulmány?
Elsődleges eredményintézkedések
Eredménymérő |
Időkeret |
|---|---|
|
Difference in the average peak velocity at maximal hyperemia between bioresorbable vascular scaffolds and everolimus-eluting stents as assessed by doppler wire measurement.
Időkeret: 1-year after stent implantation
|
1-year after stent implantation
|
Másodlagos eredményintézkedések
Eredménymérő |
Időkeret |
|---|---|
|
Difference in endothelial dysfunction with acetyl-choline infusion between bioresorbable vascular scaffolds and everolimus-eluting stents as assessed by quantitative coronary angiography (4% of lumen reduction)
Időkeret: 1-year after stent implantation
|
1-year after stent implantation
|
Egyéb eredményintézkedések
Eredménymérő |
Időkeret |
|---|---|
|
Difference in fractional flow reserve at maximal hyperemia between the two treatment groups as assessed by pressure-wire measurement
Időkeret: 1-year after stent implantation
|
1-year after stent implantation
|
Együttműködők és nyomozók
Együttműködők
Tanulmányi rekorddátumok
Tanulmány főbb dátumok
Tanulmány kezdete (Tényleges)
Elsődleges befejezés (Tényleges)
A tanulmány befejezése (Tényleges)
Tanulmányi regisztráció dátumai
Először benyújtva
Először nyújtották be, amely megfelel a minőségbiztosítási kritériumoknak
Első közzététel (Becslés)
Tanulmányi rekordok frissítései
Utolsó frissítés közzétéve (Tényleges)
Az utolsó frissítés elküldve, amely megfelel a minőségbiztosítási kritériumoknak
Utolsó ellenőrzés
Több információ
A tanulmányhoz kapcsolódó kifejezések
További vonatkozó MeSH feltételek
Egyéb vizsgálati azonosító számok
- 20151810
Ezt az információt közvetlenül a clinicaltrials.gov webhelyről szereztük be, változtatás nélkül. Ha bármilyen kérése van vizsgálati adatainak módosítására, eltávolítására vagy frissítésére, kérjük, írjon a következő címre: register@clinicaltrials.gov. Amint a változás bevezetésre kerül a clinicaltrials.gov oldalon, ez a webhelyünkön is automatikusan frissül. .