Effects on Respiratory Patterns and Patient-ventilator Synchrony Using Pressure Support Ventilation
2016年9月10日 更新者:Chun Pan、Southeast University, China
Effects on Respiratory Patterns and Patient-ventilator Synchrony in Different Ventilator Using Pressure Support Ventilation
Pressure Support Ventilation use Expiratory triggering sensitivity(Esense) to transfer inspiration to expiration,the value of Esense is fixed.That may lead to asynchrony between humans and ventilators,making people uncomfortable and prolonging weaning time.Some ventilators have auto cycle function Based on curves of pressure on respiratory patterns,it will make the transforming more synchrony with humans.Our prospective observational study will prove the superiority of the auto cycle function.
調査の概要
詳細な説明
From August 31st 2016 to August 31st 2017, all ARDS 、COPD and postoperative patients admitted to the ICUs will be enrolled.
The demographic characteristics, diagnosis, formerly medical history, Ventilator indications, Ventilator data, other respiratory treatments, weaning outcome and 28 day mortality will be recorded
研究の種類
観察的
入学 (予想される)
45
参加基準
研究者は、適格基準と呼ばれる特定の説明に適合する人を探します。これらの基準のいくつかの例は、人の一般的な健康状態または以前の治療です。
適格基準
就学可能な年齢
18年~85年 (大人、高齢者)
健康ボランティアの受け入れ
いいえ
受講資格のある性別
全て
サンプリング方法
確率サンプル
調査対象母集団
mechanical ventilation adult people using PSV mode in ICU
説明
Inclusion Criteria:
ARDS,COPD and Postoperative patient
Exclusion Criteria:
variety of reasons can not be placed next to the bed by the nasal EAdi catheter
研究計画
このセクションでは、研究がどのように設計され、研究が何を測定しているかなど、研究計画の詳細を提供します。
研究はどのように設計されていますか?
デザインの詳細
コホートと介入
グループ/コホート |
|---|
|
E5 Esense 10%
PSV mode using E5 ventilator with Esense 10%
|
|
E5 Esense 30%
PSV mode using E5 ventilator with Esense 30%
|
|
E5 Esense 50%
PSV mode using E5 ventilator with Esense 50%
|
|
Servo-I Esense 10%
PSV mode using Servo-I ventilator with Esense 10%
|
|
Servo-I Esense 30%
PSV mode using Servo-I ventilator with Esense 30%
|
|
Servo-I Esense 50%
PSV mode using Servo-I ventilator with Esense 50%
|
|
E5 Esense autocycle
PSV mode using E5 ventilator with Esense Auto cycle
|
この研究は何を測定していますか?
主要な結果の測定
結果測定 |
時間枠 |
|---|---|
|
patient-ventilator synchrony using PSV mode between different ventilator for 180mins
時間枠:180mins after the patients involved
|
180mins after the patients involved
|
二次結果の測定
結果測定 |
時間枠 |
|---|---|
|
Patient Respiratory Patterns during Pressure Support Ventilation for 180mins
時間枠:180mins
|
180mins
|
|
Patient gas exchange during Pressure Support Ventilation for 180mins
時間枠:180mins
|
180mins
|
|
Effects on Respiratory Patterns in different Expiratory triggering sensitivity for 180mins
時間枠:180mins
|
180mins
|
|
work of triggering and respiratory in different Expiratory triggering sensitivity for 180mins
時間枠:180mins
|
180mins
|
協力者と研究者
ここでは、この調査に関係する人々や組織を見つけることができます。
研究記録日
これらの日付は、ClinicalTrials.gov への研究記録と要約結果の提出の進捗状況を追跡します。研究記録と報告された結果は、国立医学図書館 (NLM) によって審査され、公開 Web サイトに掲載される前に、特定の品質管理基準を満たしていることが確認されます。
主要日程の研究
研究開始
2016年9月1日
一次修了 (予想される)
2017年8月1日
研究の完了 (予想される)
2017年8月1日
試験登録日
最初に提出
2016年7月30日
QC基準を満たした最初の提出物
2016年8月23日
最初の投稿 (見積もり)
2016年8月29日
学習記録の更新
投稿された最後の更新 (見積もり)
2016年9月13日
QC基準を満たした最後の更新が送信されました
2016年9月10日
最終確認日
2016年9月1日
詳しくは