Exploration of the Appropriate Combination of Positive End Expiratory Pressure and Tidal Volume Using the Intratidal Compliance Volume Profile in Children
Exploration of the Appropriate Combination of Positive End Expiratory Pressure and Tidal Volume Using the Intratidal Compliance-volume Profile in Children
In children under 6 years of age undergoing regular surgery during general anesthesia, the intratidal compliance profile is evaluated when different tidal volumes are applied at different positive end expiratory pressures.
Then determine the most appropriate combination of positive end-tidal pressure and tidal volume.
調査の概要
研究の種類
入学 (実際)
段階
- 適用できない
連絡先と場所
研究場所
-
-
-
Seoul、大韓民国、110-744
- Seoul National University Hospital
-
-
参加基準
適格基準
就学可能な年齢
健康ボランティアの受け入れ
受講資格のある性別
説明
Inclusion Criteria:
- Children undergoing surgery > 1 hour under general anesthesia
- Children ≤ 6 years
- American society of anesthesiology physical status I, II
Exclusion Criteria:
- Previous lung surgery
- Bronchopulmonary dysplasia, respiratory distress syndrome
- Other interstitial lung disease
- Laparoscopic surgery
- Thoracic surgery, abdominal surgery
研究計画
研究はどのように設計されていますか?
デザインの詳細
- 主な目的:他の
- 割り当て:なし
- 介入モデル:単一グループの割り当て
- マスキング:なし(オープンラベル)
武器と介入
参加者グループ / アーム |
介入・治療 |
|---|---|
|
実験的:Evaluation of intratidal compliance
When the patient is in the supine position 10 minutes after induction of anesthesia, the following 4 mechanical ventilator settings are applied to the patients in order.
|
When the patient is in the supine position 10 minutes after induction of anesthesia, the following 4 mechanical ventilator settings are applied to the patients in order. Positive end-expiratory pressure 8 cmH2O, tidal volume 8 ml/kg Positive end-expiratory pressure 10 cmH2O, tidal volume 5 ml/kg Positive end-expiratory pressure 10 cmH2O, tidal volume 8 ml/kg Positive end-expiratory pressure 12 cmH2O, tidal volume 5 ml/kg |
この研究は何を測定していますか?
主要な結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Intratidal compliance profiles in each ventilator settings
時間枠:During general anesthesia (up to about 50 min-1 hr after induction of anesthesia)
|
The investigators will determine Intratidal compliance profile using the changes in compliance over time --> I, merely increasing compliance profile; IH, increasing turning into horizontal compliance profile; D, merely decreasing compliance profile; HD, horizontal turning into decreasing compliance profile; IHD, increasing turning into horizontal and further turning into decreasing compliance profile If compliance profile is I, the PEEP is low. On the other hand, compliance profile is D, PEEP level is considered to be high. |
During general anesthesia (up to about 50 min-1 hr after induction of anesthesia)
|
二次結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Respiratory compliance
時間枠:During general anesthesia (up to about 50 min-1 hr after induction of anesthesia)
|
ml cmH2O-1
|
During general anesthesia (up to about 50 min-1 hr after induction of anesthesia)
|
|
Driving pressure
時間枠:During general anesthesia (up to about 50 min-1 hr after induction of anesthesia)
|
cmH2O
|
During general anesthesia (up to about 50 min-1 hr after induction of anesthesia)
|
|
Blood pressure
時間枠:During general anesthesia (up to about 50 min-1 hr after induction of anesthesia)
|
mmHg
|
During general anesthesia (up to about 50 min-1 hr after induction of anesthesia)
|
協力者と研究者
出版物と役立つリンク
研究記録日
主要日程の研究
研究開始 (実際)
一次修了 (実際)
研究の完了 (実際)
試験登録日
最初に提出
QC基準を満たした最初の提出物
最初の投稿 (実際)
学習記録の更新
投稿された最後の更新 (実際)
QC基準を満たした最後の更新が送信されました
最終確認日
詳しくは
本研究に関する用語
その他の研究ID番号
- H2009-175-1162
個々の参加者データ (IPD) の計画
個々の参加者データ (IPD) を共有する予定はありますか?
医薬品およびデバイス情報、研究文書
米国FDA規制医薬品の研究
米国FDA規制機器製品の研究
この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。