Biodegradable Airway Stent Post Lung Transplant
Evaluation of Treatment With Biodegradable Airway Stent for Post Lung Transplant Airway Complication
Introduction and rationale
Benign airway stenosis or malacia is a frequent complication of lung transplantation occurring in 4-24% of patients, most often occurring two to nine months post-transplant. Initial therapeutic approach consists of conservative endobronchial treatment with recurrent balloon dilatation, radial incision, and electro cautery. For severe case of recurrent stenosis or malacia, airway stent placement can be considered. Different types of airway stent exist, for instance self-extendable metallic stent (SEMS), silicone stent and biodegradable airway stent. Conventional airway stents (SEMS, silicone) are associated with complications as granulation tissue and recurrent infections and can be difficult to remove. Newly developed biodegrabale stents are made of polydioxanone and disintegrate after a period of time are thought to have less side effects, and has been standard of care for the last few years. A sub selection of patients have been treated with conventional stent before treated with biodegradable stent.
Research question
- To assess the efficacy and efficiency of biodegradable airway stent.
- Compare occurrence of adverse events such as infection, dislocation, in stent granulation and difficulty of removal to conventional metallic or silicone stents.
- Asses if biodegradable stent lead to improvement of lung function.
- Assessment of the life span of biodegradable stents.
調査の概要
詳細な説明
- Background Recurrent airway stenosis or malacia can be treated with airway stents. Conventional airway stents, for instance self-extendable metallic stent (SEMS) and silicone stent are associated with adverse events as recurrent infection or granulation tissue and can be difficult to remove because of in stent-granulation. Therefore they are used with restraint for benign airway problems. Biodegradable stents are made of polydioxanone and disintegrate after a period of time. They are thought to be well tolerated and associated with less adverse events compared to traditional airway stent and have been used as standard care for multiple years.
Main research question
- To assess the efficacy and efficiency of biodegradable airway stent
- Compare occurrence of adverse events such as infection, dislocation, in stent granulation and difficulty of removal to conventional metallic or silicone stents.
- Asses if biodegradable stent lead to improvement of lung function.
- Assessment of the life span of biodegradable stents.
- Design (including population, confounders/outcomes) Retrospective cohort study of patients with airway stenosis or malacia treated with biodegradable airway stent from 2019 in the UMCG and Amsterdam UMC.
Expected results
- Less adverse events, hospital admittance and need for bronchoscopic interventions compared to patients treated with conventional stents. No complications associated with removal of stents.
- Life span around 4 months
研究の種類
入学 (実際)
段階
- 適用できない
連絡先と場所
研究場所
-
-
-
Amsterdam、オランダ
- AMC
-
Groningen、オランダ
- UMCG
-
-
参加基準
適格基準
就学可能な年齢
健康ボランティアの受け入れ
受講資格のある性別
説明
Inclusion Criteria:
- Patients who underwent a lung transplantation and developed airway stenosis or malacia with airway stent requirement
Exclusion Criteria:
- No
研究計画
研究はどのように設計されていますか?
デザインの詳細
- 主な目的:処理
- 割り当て:なし
- 介入モデル:単一グループの割り当て
- マスキング:なし(オープンラベル)
武器と介入
参加者グループ / アーム |
介入・治療 |
|---|---|
|
実験的:Biodegradable stent treatment group
|
Bronchoscopic placement of biodegradable stent in patients with airway complications after lung transplant
|
この研究は何を測定していますか?
主要な結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Adverse events
時間枠:4 months after placement
|
Adverse events associated with airway stents
|
4 months after placement
|
二次結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Change in FEV1
時間枠:1 week post placement
|
Change in FEV1 measured by spirometry pre and post stent placement
|
1 week post placement
|
|
Change in FVC
時間枠:1 week post placement
|
Change in FVC measured by spirometry pre and post stent placement
|
1 week post placement
|
|
Time to need for new stent placement
時間枠:6 months after placement
|
Endurance and life span of biodegradable stent measured by time to need for new stent placement
|
6 months after placement
|
協力者と研究者
捜査官
- 主任研究者:Dirk-Jan Slebos, MD, PhD、UMCG
研究記録日
主要日程の研究
研究開始 (実際)
一次修了 (実際)
研究の完了 (実際)
試験登録日
最初に提出
QC基準を満たした最初の提出物
最初の投稿 (実際)
学習記録の更新
投稿された最後の更新 (実際)
QC基準を満たした最後の更新が送信されました
最終確認日
詳しくは
本研究に関する用語
その他の研究ID番号
- 20220075
個々の参加者データ (IPD) の計画
個々の参加者データ (IPD) を共有する予定はありますか?
医薬品およびデバイス情報、研究文書
米国FDA規制医薬品の研究
米国FDA規制機器製品の研究
この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。