- ICH GCP
- US-Register für klinische Studien
- Klinische Studie NCT05334199
Biodegradable Airway Stent Post Lung Transplant
Evaluation of Treatment With Biodegradable Airway Stent for Post Lung Transplant Airway Complication
Introduction and rationale
Benign airway stenosis or malacia is a frequent complication of lung transplantation occurring in 4-24% of patients, most often occurring two to nine months post-transplant. Initial therapeutic approach consists of conservative endobronchial treatment with recurrent balloon dilatation, radial incision, and electro cautery. For severe case of recurrent stenosis or malacia, airway stent placement can be considered. Different types of airway stent exist, for instance self-extendable metallic stent (SEMS), silicone stent and biodegradable airway stent. Conventional airway stents (SEMS, silicone) are associated with complications as granulation tissue and recurrent infections and can be difficult to remove. Newly developed biodegrabale stents are made of polydioxanone and disintegrate after a period of time are thought to have less side effects, and has been standard of care for the last few years. A sub selection of patients have been treated with conventional stent before treated with biodegradable stent.
Research question
- To assess the efficacy and efficiency of biodegradable airway stent.
- Compare occurrence of adverse events such as infection, dislocation, in stent granulation and difficulty of removal to conventional metallic or silicone stents.
- Asses if biodegradable stent lead to improvement of lung function.
- Assessment of the life span of biodegradable stents.
Studienübersicht
Status
Bedingungen
Intervention / Behandlung
Detaillierte Beschreibung
- Background Recurrent airway stenosis or malacia can be treated with airway stents. Conventional airway stents, for instance self-extendable metallic stent (SEMS) and silicone stent are associated with adverse events as recurrent infection or granulation tissue and can be difficult to remove because of in stent-granulation. Therefore they are used with restraint for benign airway problems. Biodegradable stents are made of polydioxanone and disintegrate after a period of time. They are thought to be well tolerated and associated with less adverse events compared to traditional airway stent and have been used as standard care for multiple years.
Main research question
- To assess the efficacy and efficiency of biodegradable airway stent
- Compare occurrence of adverse events such as infection, dislocation, in stent granulation and difficulty of removal to conventional metallic or silicone stents.
- Asses if biodegradable stent lead to improvement of lung function.
- Assessment of the life span of biodegradable stents.
- Design (including population, confounders/outcomes) Retrospective cohort study of patients with airway stenosis or malacia treated with biodegradable airway stent from 2019 in the UMCG and Amsterdam UMC.
Expected results
- Less adverse events, hospital admittance and need for bronchoscopic interventions compared to patients treated with conventional stents. No complications associated with removal of stents.
- Life span around 4 months
Studientyp
Einschreibung (Tatsächlich)
Phase
- Unzutreffend
Kontakte und Standorte
Studienorte
-
-
-
Amsterdam, Niederlande
- AMC
-
Groningen, Niederlande
- UMCG
-
-
Teilnahmekriterien
Zulassungskriterien
Studienberechtigtes Alter
Akzeptiert gesunde Freiwillige
Studienberechtigte Geschlechter
Beschreibung
Inclusion Criteria:
- Patients who underwent a lung transplantation and developed airway stenosis or malacia with airway stent requirement
Exclusion Criteria:
- No
Studienplan
Wie ist die Studie aufgebaut?
Designdetails
- Hauptzweck: Behandlung
- Zuteilung: N / A
- Interventionsmodell: Einzelgruppenzuweisung
- Maskierung: Keine (Offenes Etikett)
Waffen und Interventionen
Teilnehmergruppe / Arm |
Intervention / Behandlung |
|---|---|
|
Experimental: Biodegradable stent treatment group
|
Bronchoscopic placement of biodegradable stent in patients with airway complications after lung transplant
|
Was misst die Studie?
Primäre Ergebnismessungen
Ergebnis Maßnahme |
Maßnahmenbeschreibung |
Zeitfenster |
|---|---|---|
|
Adverse events
Zeitfenster: 4 months after placement
|
Adverse events associated with airway stents
|
4 months after placement
|
Sekundäre Ergebnismessungen
Ergebnis Maßnahme |
Maßnahmenbeschreibung |
Zeitfenster |
|---|---|---|
|
Change in FEV1
Zeitfenster: 1 week post placement
|
Change in FEV1 measured by spirometry pre and post stent placement
|
1 week post placement
|
|
Change in FVC
Zeitfenster: 1 week post placement
|
Change in FVC measured by spirometry pre and post stent placement
|
1 week post placement
|
|
Time to need for new stent placement
Zeitfenster: 6 months after placement
|
Endurance and life span of biodegradable stent measured by time to need for new stent placement
|
6 months after placement
|
Mitarbeiter und Ermittler
Mitarbeiter
Ermittler
- Hauptermittler: Dirk-Jan Slebos, MD, PhD, UMCG
Studienaufzeichnungsdaten
Haupttermine studieren
Studienbeginn (Tatsächlich)
Primärer Abschluss (Tatsächlich)
Studienabschluss (Tatsächlich)
Studienanmeldedaten
Zuerst eingereicht
Zuerst eingereicht, das die QC-Kriterien erfüllt hat
Zuerst gepostet (Tatsächlich)
Studienaufzeichnungsaktualisierungen
Letztes Update gepostet (Tatsächlich)
Letztes eingereichtes Update, das die QC-Kriterien erfüllt
Zuletzt verifiziert
Mehr Informationen
Begriffe im Zusammenhang mit dieser Studie
Andere Studien-ID-Nummern
- 20220075
Plan für individuelle Teilnehmerdaten (IPD)
Planen Sie, individuelle Teilnehmerdaten (IPD) zu teilen?
Arzneimittel- und Geräteinformationen, Studienunterlagen
Studiert ein von der US-amerikanischen FDA reguliertes Arzneimittelprodukt
Studiert ein von der US-amerikanischen FDA reguliertes Geräteprodukt
Diese Informationen wurden ohne Änderungen direkt von der Website clinicaltrials.gov abgerufen. Wenn Sie Ihre Studiendaten ändern, entfernen oder aktualisieren möchten, wenden Sie sich bitte an register@clinicaltrials.gov. Sobald eine Änderung auf clinicaltrials.gov implementiert wird, wird diese automatisch auch auf unserer Website aktualisiert .
Klinische Studien zur Biodegradable stent
-
Zhujiang HospitalBeijing Tiantan Hospital; Guangdong Provincial People's Hospital; First Affiliated... und andere MitarbeiterAbgeschlossenBehandlungsergebnis durch Stent-gestützte EmbolisationChina
-
Chang Gung Memorial HospitalNoch keine RekrutierungKoronare HerzkrankheitTaiwan
-
UMC UtrechtUnbekanntAkutes Koronar-Syndrom | Stabile Angina pectorisNiederlande, Luxemburg
-
Shanghai Jiao Tong University School of MedicineUnbekanntIntrakranielle AneurysmenChina
-
St. Petersburg State Pavlov Medical UniversityAbgeschlossen
-
Associations for Establishment of Evidence in InterventionsAbgeschlossenKoronare HerzkrankheitJapan
-
Yonsei UniversityRekrutierungAkutes Koronar-SyndromKorea, Republik von
-
Biotronik, Inc.AbgeschlossenPeriphere Gefäßerkrankung | Periphere arterielle VerschlusskrankheitKanada, Vereinigte Staaten
-
M.D. Anderson Cancer CenterNational Cancer Institute (NCI)BeendetBösartige Kopf-Hals-NeubildungVereinigte Staaten
-
Cordis CorporationAbgeschlossenArterielle VerschlusskrankheitenDeutschland